Monte Carlo simulations of a novel coherent scatter materials discrimination system

被引:0
|
作者
Hassan, Laila [1 ]
Starr-Baier, Sean [1 ]
MacDonald, C. A. [1 ]
Petruccelli, Jonathan C. [1 ]
机构
[1] SUNY Albany, Albany, NY 12222 USA
关键词
coherent scatter; diffraction; x-ray imaging; materials discrimination; non-destructive analysis; security screening; X-RAY-SCATTERING; BREAST-TISSUE; CANCER;
D O I
10.1117/12.2262895
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray coherent scatter imaging has the potential to improve the detection of liquid and powder materials of concern in security screening. While x-ray attenuation is dependent on atomic number, coherent scatter is highly dependent on the characteristic angle for the target material, and thus offers an additional discrimination. Conventional coherent scatter analysis requires pixel-by-pixel scanning, and so could be prohibitively slow for security applications. A novel slot scan system has been developed to provide rapid imaging of the coherent scatter at selected angles of interest, simultaneously with the conventional absorption images. Prior experimental results showed promising capability. In this work, Monte Carlo simulations were performed to assess discrimination capability and provide system optimization. Simulation analysis performed using the measured ring profiles for an array of powders and liquids, including water, sugar, ethanol and peroxide. For example, simulations yielded a signal-to-background ratio of 1.63 +/- 0.08 for a sample consisting of two 10 mm diameter vials, one containing ethanol (signal) and one water (background). This high SBR value is due to the high angular separation of the coherent scatter between the two liquids. The results indicate that the addition of coherent scatter information to single or dual energy attenuation images improves the discrimination of materials of interest.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Coherent scatter imaging Monte Carlo simulation
    Hassan, Laila
    MacDonald, Carolyn A.
    [J]. JOURNAL OF MEDICAL IMAGING, 2016, 3 (03)
  • [2] Monte Carlo Simulation of Coherent Scatter Computed Tomography (CSCT)
    Lewis, K.
    Donnelly, E.
    Pickens, D.
    Price, R.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [3] Scatter analysis of the ClearPET™ neuro using Monte Carlo simulations
    Fulterer, Anna M.
    Schneider, Stephan
    Gundlich, Brigitte
    Musmann, Patrick
    Weber, Simone
    Buzug, Thorsten M.
    [J]. ADVANCES IN MEDICAL ENGINEERING, 2007, 114 : 109 - +
  • [4] COHERENT SCATTER IN RADIOGRAPHIC IMAGING - A MONTE-CARLO SIMULATION STUDY
    NEITZEL, U
    KOSANETZKY, J
    HARDING, G
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (12): : 1289 - 1296
  • [5] Advances in Monte Carlo simulations of nanostructured materials
    Hadjisavvas, G. C.
    Kelires, P. C.
    [J]. COMPUTER SIMULATION STUDIES IN CONDENSED-MATTER PHYSICS XVIII, 2006, 105 : 58 - +
  • [6] Monte Carlo simulations of surfaces and interfaces in materials
    Binder, K
    [J]. STABILITY OF MATERIALS, 1996, 355 : 3 - 36
  • [7] Calculation of Photon Path Changes due to Scatter in Monte Carlo Simulations
    Phillips, Justin P.
    Kyriacou, Panayiotis A.
    Jones, Deric P.
    [J]. 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 4959 - 4962
  • [8] Use of Monte Carlo simulations for the scatter events analysis of PET scanners
    Gao Fei
    Yamada, Ryoko
    Watanabe, Mitsuo
    Liu Hua-Feng
    [J]. ACTA PHYSICA SINICA, 2009, 58 (05) : 3584 - 3591
  • [9] A SETUP FOR KV CBCT SCATTER PREDICTION USING MONTE CARLO SIMULATIONS
    Poels, K.
    Van den Heuvel, F.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S47 - S48
  • [10] Investigation of scatter from out of the field of view and multiple scatter in PET using Monte Carlo simulations
    Ye Ting
    Chai Pei
    Gao Juan
    Yun Ming-Kai
    Liu Shuang-Quan
    Shan Bao-Ci
    Wei Long
    [J]. CHINESE PHYSICS C, 2011, 35 (12) : 1166 - 1171