Monte Carlo simulations of a novel coherent scatter materials discrimination system

被引:0
|
作者
Hassan, Laila [1 ]
Starr-Baier, Sean [1 ]
MacDonald, C. A. [1 ]
Petruccelli, Jonathan C. [1 ]
机构
[1] SUNY Albany, Albany, NY 12222 USA
关键词
coherent scatter; diffraction; x-ray imaging; materials discrimination; non-destructive analysis; security screening; X-RAY-SCATTERING; BREAST-TISSUE; CANCER;
D O I
10.1117/12.2262895
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray coherent scatter imaging has the potential to improve the detection of liquid and powder materials of concern in security screening. While x-ray attenuation is dependent on atomic number, coherent scatter is highly dependent on the characteristic angle for the target material, and thus offers an additional discrimination. Conventional coherent scatter analysis requires pixel-by-pixel scanning, and so could be prohibitively slow for security applications. A novel slot scan system has been developed to provide rapid imaging of the coherent scatter at selected angles of interest, simultaneously with the conventional absorption images. Prior experimental results showed promising capability. In this work, Monte Carlo simulations were performed to assess discrimination capability and provide system optimization. Simulation analysis performed using the measured ring profiles for an array of powders and liquids, including water, sugar, ethanol and peroxide. For example, simulations yielded a signal-to-background ratio of 1.63 +/- 0.08 for a sample consisting of two 10 mm diameter vials, one containing ethanol (signal) and one water (background). This high SBR value is due to the high angular separation of the coherent scatter between the two liquids. The results indicate that the addition of coherent scatter information to single or dual energy attenuation images improves the discrimination of materials of interest.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Automation of Monte Carlo simulations for a proton therapy system
    Zheng, Y.
    Newhauser, W.
    Fontenot, J.
    Koch, N.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2073 - 2074
  • [42] Monte Carlo simulations of the neutron wall detector system
    Ljungvall, J
    Palacz, M
    Nyberg, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 528 (03): : 741 - 762
  • [43] Numerical Discrimination of Thermodynamic Monte Carlo Simulations in All Eight Statistical Ensembles
    Nitzke, Isabel
    Vrabec, Jadran
    [J]. JOURNAL OF CHEMICAL THEORY AND COMPUTATION, 2023, 19 (12) : 3460 - 3468
  • [44] Monte Carlo simulation of the coherent backscattering of electrons in a ballistic system
    Janssens, KL
    Peeters, EM
    [J]. SUPERLATTICES AND MICROSTRUCTURES, 1999, 25 (04) : 615 - 621
  • [45] Monte Carlo simulation of shot noise in the coherent and mesoscopic system
    Chen Hua
    Du Lei
    Zhuang Yi-Qi
    [J]. ACTA PHYSICA SINICA, 2008, 57 (04) : 2438 - 2444
  • [46] EXPERIMENTALLY MEASURED SCATTER FRACTIONS AND ENERGY-SPECTRA AS A TEST OF MONTE-CARLO SIMULATIONS
    MANGLOS, SH
    FLOYD, CE
    JASZCZAK, RJ
    GREER, KL
    HARRIS, CC
    COLEMAN, RE
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (03): : 335 - 343
  • [47] Convolution-based scatter correction using kernels combining measurements and Monte Carlo simulations
    Bhatia, Navnina
    Tisseur, David
    Letang, Jean Michel
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (04) : 613 - 628
  • [48] Characterisation of Scatter and Attenuation in GE Discovery 530c using Monte Carlo simulations
    Peterson, M.
    Ljungberg, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S93 - S93
  • [49] Characterization of scatter in digital mammography from use of Monte Carlo simulations and comparison to physical measurements
    Leon, Stephanie M.
    Brateman, Libby F.
    Wagner, Louis K.
    [J]. MEDICAL PHYSICS, 2014, 41 (11)
  • [50] Excitons in novel quantum materials: A Monte Carlo study
    Wang, EG
    [J]. ELECTRO-OPTIC AND SECOND HARMONIC GENERATION MATERIALS, DEVICES, AND APPLICATIONS, 1996, 2897 : 68 - 74