Calculation of Photon Path Changes due to Scatter in Monte Carlo Simulations

被引:4
|
作者
Phillips, Justin P. [1 ]
Kyriacou, Panayiotis A. [1 ]
Jones, Deric P. [1 ]
机构
[1] City Univ London, Sch Engn & Math Sci, London EC1V 0HB, England
关键词
OPTICAL-PROPERTIES; TISSUE; MODEL; LIGHT;
D O I
10.1109/IEMBS.2010.5627216
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Computation using Monte Carlo simulations is widely used for modelling the light-tissue interaction. Despite this, many of the methods used for building such simulations are poorly described in the literature. In particular, a scheme for translating the scatter angles produced from a phase function into updated photon direction vectors is not explicitly reported. To address this, a method for calculating the change in photon direction following a scattering event is described, thus illuminating one of the fundamental 'building blocks' for researchers developing their own Monte Carlo models. The equations derived in this paper may be readily incorporated into applicable Monte Carlo program code.
引用
收藏
页码:4959 / 4962
页数:4
相关论文
共 50 条
  • [1] MONTE-CARLO PET SIMULATIONS - EFFECT OF PHOTON POLARIZATION ON SCATTER ESTIMATES
    BICE, AN
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (05): : 1185 - 1188
  • [2] Investigation of the scatter contribution in single photon transmission measurements by means of Monte Carlo simulations
    Wegmann, K
    Adam, LE
    Livieratos, L
    Zaers, J
    Bailey, DL
    Brix, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) : 1184 - 1190
  • [3] Photon Spectra calculation for an Elekta linac beam using experimental scatter measurements and Monte Carlo techniques
    Juste, B.
    Miro, R.
    Campayo, J. M.
    Diez, S.
    Verdu, G.
    [J]. 2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 3289 - +
  • [4] Deformation of Optics for Photon Monte Carlo Simulations
    Peterson, J. R.
    Peng, E.
    Burke, C. J.
    Sembroski, G.
    Cheng, J.
    [J]. ASTROPHYSICAL JOURNAL, 2019, 873 (01):
  • [5] Evaluation of a scatter correction technique for single photon transmission measurements in PET by means of Monte Carlo simulations
    Wegmann, K
    Brix, G
    [J]. NUKLEARMEDIZIN, 2000, 39 (03) : 67 - 71
  • [6] ON PATH INTEGRAL MONTE-CARLO SIMULATIONS
    HERMAN, MF
    BRUSKIN, EJ
    BERNE, BJ
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1982, 76 (10): : 5150 - 5155
  • [7] Scatter analysis of the ClearPET™ neuro using Monte Carlo simulations
    Fulterer, Anna M.
    Schneider, Stephan
    Gundlich, Brigitte
    Musmann, Patrick
    Weber, Simone
    Buzug, Thorsten M.
    [J]. ADVANCES IN MEDICAL ENGINEERING, 2007, 114 : 109 - +
  • [8] Evaluation of scatter to primary ratio at an EPID with Monte Carlo calculation
    Wang, L
    Chen, J
    Yorke, E
    Chui, C
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1245 - 1245
  • [9] Monte Carlo simulation of spectrum changes in a photon beam due to a brass compensator
    Custidiano, E. R.
    Valenzuela, M. R.
    Dumont, J. L.
    McDonnell, J.
    Rene, L.
    Rodriguez Aguirre, J. M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (12): : 1444 - 1449
  • [10] Fast Monte Carlo calculation of scatter corrections for CBCT images
    Mainegra-Hing, Ernesto
    Kawrakow, Iwan
    [J]. INTERNATIONAL WORKSHOP ON MONTE CARLO TECHNIQUES IN RADIOTHERAPY DELIVERY AND VERIFICATION - THIRD MCGILL INTERNATIONAL WORKSHOP, 2008, 102