Evaluation of scatter to primary ratio at an EPID with Monte Carlo calculation

被引:0
|
作者
Wang, L
Chen, J
Yorke, E
Chui, C
机构
[1] Fox Chase Canc Ctr, Philadelphia, PA 19111 USA
[2] Mem Sloan Kettering Canc Ctr, New York, NY 10021 USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:1245 / 1245
页数:1
相关论文
共 50 条
  • [1] A Monte Carlo evaluation of the channel ratio scatter correction method
    Naude, H
    vanAswegen, A
    Herbst, CP
    Lotter, MG
    Pretorius, PH
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (06): : 1059 - 1066
  • [2] Scatter/primary in mammography: Monte Carlo validation
    Boone, JM
    Cooper, VN
    [J]. MEDICAL PHYSICS, 2000, 27 (08) : 1818 - 1831
  • [3] MONTE-CARLO CALCULATIONS OF SCATTER TO PRIMARY RATIOS FOR NORMALIZATION OF PRIMARY AND SCATTER DOSE
    RICE, RK
    CHIN, LM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (03): : 333 - 338
  • [4] Analytical calculation of the portal scatter to primary dose ratio: an EGS4 Monte Carlo and experimental validation at large air gaps
    Ozard, SR
    Grein, EE
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (06): : 1719 - 1736
  • [5] Fast Monte Carlo calculation of scatter corrections for CBCT images
    Mainegra-Hing, Ernesto
    Kawrakow, Iwan
    [J]. INTERNATIONAL WORKSHOP ON MONTE CARLO TECHNIQUES IN RADIOTHERAPY DELIVERY AND VERIFICATION - THIRD MCGILL INTERNATIONAL WORKSHOP, 2008, 102
  • [6] Calculation of Photon Path Changes due to Scatter in Monte Carlo Simulations
    Phillips, Justin P.
    Kyriacou, Panayiotis A.
    Jones, Deric P.
    [J]. 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 4959 - 4962
  • [7] Fast Monte Carlo calculation of linear accelerator head scatter factors
    MacPherson, M
    Badeen, A
    Wilkins, D
    Gerig, L
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1203 - 1203
  • [8] Monte Carlo calculation of point spread functions of Compton scatter cameras
    Wilderman, SJ
    Rogers, WL
    Knoll, GF
    Engdahl, JC
    [J]. 1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1538 - 1542
  • [9] Comprehensive Monte Carlo calculation of the point spread function for a commercial a-Si EPID
    Kirkby, C
    Sloboda, R
    [J]. MEDICAL PHYSICS, 2005, 32 (04) : 1115 - 1127
  • [10] Dedicated Cone-Beam Breast CT with Laterally-Shifted Detector: Monte Carlo Evaluation of X-Ray Scatter Distribution and Scatter-To-Primary Ratio
    Shi, L.
    Vedantham, S.
    Karellas, A.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3682 - 3682