In Vitro Fatigue and Fracture Load of Monolithic Ceramic Crowns Supported by Hybrid Abutment

被引:0
|
作者
Nawafleh, Noor [1 ]
Elshiyab, Shareen [1 ]
Ochsner, Andreas [2 ,3 ]
George, Roy [4 ]
机构
[1] Jordan Univ Sci & Technol, Fac Appl Med Sci, Irbid 22110, Jordan
[2] Esslingen Univ Appl Sci, Fac Mech Engn, Esslingen, Germany
[3] Univ Newcastle, Fac Engn & Built Environm, Newcastle, NSW, Australia
[4] Griffith Univ, Sch Dent & Oral Hlth, Gold Coast, Qld, Australia
来源
OPEN DENTISTRY JOURNAL | 2021年 / 15卷
关键词
Chewing simulation; Fatigue; Fracture resistance; Lithium disilicate; Zirconia; Hybrid abutment; Dental implant; FIXED DENTAL PROSTHESES; LITHIUM DISILICATE CROWNS; ZIRCONIA-BASED CROWNS; MEAN FOLLOW-UP; SINGLE CROWNS; CLINICAL-EVALUATION; PREPARATION DESIGNS; CAD/CAM-MATERIALS; SURVIVAL RATES; MOLAR CROWNS;
D O I
10.2174/1874210602115010664
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: This study evaluated the performance of zirconia and lithium disilicate crowns supported by implants or cemented to epoxy resin dies. Methods: Eigthy zirconia and lithium disilicate crowns each were prepared and assigned in four groups according to the crown material and supporting structure combinations (implant-supported zirconia, die-supported zirconia, implant-supported lithium disilicate, and die-supported lithium disilicate). Ten crowns in each group acted as control while the rest (n=10) underwent thermocycling and fatigue with 100 N loading force for 1.5 million cycles. Specimens were then loaded to fracture in a universal testing machine. Data were analysed using one-way ANOVA and Tukey multiple comparison test with a 95% level of significance. Results: No implants or crown failure occurred during fatigue. The mean fracture load values (control, fatigued) in newton Were as follows: (4054, 3344) for implant-supported zirconia, (3783, 3477) for die-supported zirconia, (2506, 2207) for implant-supported lithium disilicate, and (2159, 1806) for die-supported lithium disilicate. Comparing the control with the corresponding fatigued subgroup showed a significantly higher fracture load mean of the control group in all cases. Zirconia showed a significantly higher fracture load mean than lithium disilicate (P=0.001, P<0.001). However, comparing crowns made from the same material according to the supporting structure showed no significant difference (P=0.923, P=0.337). Conclusion: Zirconia and lithium disilicate posterior crowns have adequate fatigue and fracture resistance required for posterior crowns. However, when heavy fatigue forces are expected, zirconia material is preferable over lithium disilicate. Zirconia and lithium disilicate implant-supported crowns cemented to hybrid abutments should have satisfactory clinical performance.
引用
收藏
页码:664 / 671
页数:8
相关论文
共 50 条
  • [21] Fatigue resistance of monolithic CAD/CAM ceramic crowns on human premolars
    Homaei, Ehsan
    Farhangdoost, Khalil
    Pow, Edmond Ho Nang
    Matinlinna, Jukka Pekka
    Akbari, Majid
    Tsoi, James Kit-Hon
    CERAMICS INTERNATIONAL, 2016, 42 (14) : 15709 - 15717
  • [22] Mechanical stability and technical outcomes of monolithic CAD/CAM fabricated abutment-crowns supported by titanium bases: An in vitro study
    Pitta, Joao
    Hjerppe, Jenni
    Burkhardt, Felix
    Fehmer, Vincent
    Mojon, Philippe
    Sailer, Irena
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (02) : 222 - 232
  • [23] Fracture load and survival of anatomically representative monolithic lithium disilicate crowns with reduced tooth preparation and ceramic thickness
    Nawafleh, Noor A.
    Hatamleh, Muhanad M.
    Ochsner, Andreas
    Mack, Florian
    JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (06): : 416 - 422
  • [24] Load Fatigue Performance of Implant-Ceramic Abutment Combinations
    Nguyen, Huong Q.
    Tan, Keson B.
    Nicholls, Jack I.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (04) : 636 - 646
  • [25] Fracture behaviors of monolithic lithium disilicate ceramic crowns with different thicknesses
    Yu, Tao
    Wang, Fu
    Liu, Yan
    Wu, Tao
    Deng, Zaixi
    Chen, Jihua
    RSC ADVANCES, 2017, 7 (41) : 25542 - 25548
  • [26] Effect of abutment design on fracture resistance of resin-matrix ceramic crowns for dental implant restoration: an in vitro study
    Lin, Jie
    Cai, Pingping
    Zhuo, Yingying
    Lin, Ling
    Zheng, Zhiqiang
    BMC ORAL HEALTH, 2023, 23 (01)
  • [27] Effect of abutment design on fracture resistance of resin-matrix ceramic crowns for dental implant restoration: an in vitro study
    Jie Lin
    Pingping Cai
    Yingying Zhuo
    Ling Lin
    Zhiqiang Zheng
    BMC Oral Health, 23
  • [28] Fracture Load of Implant-Supported Zirconia All-Ceramic Crowns Luted with Various Cements
    Lim, Hyun-Pil
    Yoo, Jeong-Min
    Park, Sang-Won
    Yang, Hong-So
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2010, 23 (04) : 361 - 363
  • [29] Fracture Strength of Zirconia and Alumina Ceramic Crowns Supported by Implants
    Traini, Tonino
    Sorrentino, Roberto
    Gherlone, Enrico
    Perfetti, Federico
    Bollero, Patrizio
    Zarone, Ferdinando
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 : 352 - 359
  • [30] Fracture resistance of different implant supported ceramic abutment/crown systems
    Gungor, Merve Bankoglu
    Nemli, Secil Karakoca
    Yilmaz, Handan
    Aydin, Cemal
    EUROPEAN ORAL RESEARCH, 2019, 53 (02) : 80 - 87