Mechanical stability and technical outcomes of monolithic CAD/CAM fabricated abutment-crowns supported by titanium bases: An in vitro study

被引:31
|
作者
Pitta, Joao [1 ]
Hjerppe, Jenni [2 ,3 ]
Burkhardt, Felix [1 ]
Fehmer, Vincent [1 ]
Mojon, Philippe [1 ]
Sailer, Irena [1 ]
机构
[1] Univ Geneva, Univ Clin Dent Med, Div Fixed Prosthodont & Biomat, 1 Rue Michel Servet, CH-1211 Geneva 4, Switzerland
[2] Helsinki Univ Hosp HUH, Dept Oral & Maxillofacial Dis, Helsinki, Finland
[3] Univ Turku, Dept Prosthodont & Stomatognath Physiol, Turku, Finland
关键词
crowns; dental abutments; dental implants; fracture load; metal ceramic; monolithic; zircona; ZIRCONIA IMPLANT ABUTMENTS; ALL-CERAMIC CROWNS; LITHIUM DISILICATE; CLINICAL-PERFORMANCE; FRACTURE STRENGTH; DIGITAL WORKFLOW; BENDING MOMENTS; SINGLE CROWNS; RESTORATIONS; TOOTH;
D O I
10.1111/clr.13693
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To evaluate mechanical stability (survival and complication rates) and bending moments of different all-ceramic monolithic restorations bonded to titanium bases (hybrid abutment-crowns) or to customized titanium abutments compared to porcelain-fused-to-metal crowns (PFM) after thermo-mechanical aging. Material and Methods Sixty conical connection implants (4.3 mm-diameter) were divided in five groups (n = 12): PFM using gold abutment (GAbut-PFM), lithium disilicate crown bonded to customized titanium abutment (TAbut+LDS), lithium disilicate abutment-crown bonded to titanium base (TiBase+LDS), zirconia abutment-crown bonded to titanium base (TiBase+ZR), polymer-infiltrated ceramic-network (PICN) abutment-crown bonded to titanium base (TiBase+PICN). Simultaneous thermocycling (5 degrees-55 degrees C) and chewing simulation (1,200,000-cycles, 49 N, 1.67 Hz) were applied. Catastrophic and non-catastrophic events were evaluated under light microscope, and survival and complication rates were calculated. Specimens that survived aging were loaded until failure and bending moments were calculated. Results Survival rates after aging were 100% (TAbut+LDS, TiBase+LDS), 91.7% (GA-PFM), 66.7% (TiBase+ZR) and 58.3% (TiBase+PICN) and differed among the groups (p = .006). Non-catastrophic events as screw loosening (GA-PFM) and loss of retention or micro-/macro-movement (TiBase groups) were observed. Complication rates varied among the groups (p < .001). TiBase+PICN had lower bending moment than all the other groups (p < .001). Conclusions Hybrid abutment-crowns made of lithium disilicate can be an alternative to PFM-based restorations, although concerns regarding the bonded interface between the titanium base and abutment-crown can be raised. PICN and zirconia may not be recommended due to its inferior mechanical and bonding outcomes, respectively. Titanium customized abutment with bonded lithium disilicate crown appears to be the most stable combination.
引用
收藏
页码:222 / 232
页数:11
相关论文
共 47 条
  • [1] Fracture Resistance of Molar Crowns Fabricated with Monolithic All-Ceramic CAD/CAM Materials Cemented on Titanium Abutments: An In Vitro Study
    Dogan, Derya Ozdemir
    Gorler, Oguzhan
    Mutaf, Burcu
    Ozcan, Mutlu
    Eyuboglu, Gunes Bulut
    Ulgey, Melih
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (04): : 309 - 314
  • [2] In vitro performance and fracture resistance of CAD/CAM-fabricated implant supported molar crowns
    Martin Rosentritt
    Sebastian Hahnel
    Frank Engelhardt
    Michael Behr
    Verena Preis
    Clinical Oral Investigations, 2017, 21 : 1213 - 1219
  • [3] In-vitro performance of CAD/CAM-fabricated implant-supported temporary crowns
    Rosentritt, Martin
    Raab, Philipp
    Hahnel, Sebastian
    Stoeckle, Matthias
    Preis, Verena
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (08) : 2581 - 2587
  • [4] In vitro performance and fracture resistance of CAD/CAM-fabricated implant supported molar crowns
    Rosentritt, Martin
    Hahnel, Sebastian
    Engelhardt, Frank
    Behr, Michael
    Preis, Verena
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (04) : 1213 - 1219
  • [5] In-vitro performance of CAD/CAM-fabricated implant-supported temporary crowns
    Martin Rosentritt
    Philipp Raab
    Sebastian Hahnel
    Matthias Stöckle
    Verena Preis
    Clinical Oral Investigations, 2017, 21 : 2581 - 2587
  • [6] Marginal and Internal Fit of Monolithic Zirconia Crowns Fabricated by Using Two Different CAD-CAM Workflows: An In Vitro Study
    Cin, Vahap
    Izgi, Ayca Deniz
    Kale, Ediz
    Yilmaz, Burak
    PROSTHESIS, 2023, 5 (01): : 35 - 47
  • [7] Mechanical Assessment of CAD/CAM Fabricated Hybrid Ceramics: An In Vitro Study
    Alanazi, Khalid K.
    Alzaid, Abdulaziz A.
    Elkaffas, Ali A.
    Bukhari, Sarah A.
    Althubaitiy, Ramzi O.
    Alfaifi, Khalid A.
    Alfahdi, Ibrahim M.
    Alqahtani, Hussain A.
    APPLIED SCIENCES-BASEL, 2024, 14 (17):
  • [8] Fracture strength of implant-supported hybrid abutment crowns in premolar region fabricated using different restorative CAD/CAM materials
    Takano, Ryoki
    Honda, Junichi
    Kobayashi, Tatsuro
    Kubochi, Kei
    Takata, Hiroki
    Komine, Futoshi
    DENTAL MATERIALS JOURNAL, 2023, 42 (02) : 187 - 192
  • [9] In vitro assessment of cementation of CAD/CAM fabricated prostheses over titanium bases. A systematic review
    Ntovas, Panagiotis
    Ladia, Ourania
    Pachiou, Aspasia
    Fehmer, Vincent
    Sailer, Irena
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (10) : 1203 - 1225
  • [10] Fatigue resistance of anterior monolithic crowns produced from CAD-CAM materials: An in vitro study
    Choo, Seung-Sik
    Ko, Kyung-Ho
    Huh, Yoon-Hyuk
    Park, Chan-Jin
    Cho, Lee-Ra
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (04): : 620 - 628