In vitro assessment of cementation of CAD/CAM fabricated prostheses over titanium bases. A systematic review

被引:1
|
作者
Ntovas, Panagiotis [1 ]
Ladia, Ourania [2 ]
Pachiou, Aspasia [2 ]
Fehmer, Vincent [3 ]
Sailer, Irena [3 ]
机构
[1] Tufts Univ, Sch Dent Med, Dept Prosthodont, 630 Washington St, Boston, MA 02111 USA
[2] Natl & Kapodistrian Univ Athens, Sch Dent, Dept Prosthodont, Athens, Greece
[3] Univ Clin Dent Med, Univ Geneva, Div Fixed Prosthodont & Biomat, Geneva, Switzerland
关键词
CAD/CAM; de-bonding; hybrid abutment; implant prosthesis; implant-supported crown; systematic review; titanium-based abutment; FIXED DENTAL PROSTHESES; IMPLANT ABUTMENTS; COMPLICATION RATES; SURFACE TREATMENTS; CLINICAL-TRIAL; SINGLE CROWNS; SURVIVAL; RESTORATIONS; RETENTION; INTERFACE;
D O I
10.1111/clr.14347
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The objective of this study is to investigate the outcomes of clinically relevant laboratory studies regarding the cementation of implant-supported restorations over ti-bases. Materials and Methods: The present study has been conducted according to PRISMA statement. An electronic search was performed, including publications up to March 2024, to identify studies investigating the parameters affecting the cementation between ti-bases and CAD/CAM prostheses. An assessment of the internal validity was performed, using a custom-made risk of bias tool (QUIN). Results: From the included studies, 40.1% were reported on luting systems, 25% on ti-base surface treatment, 25% on restoration surface, 21.8% on restoration material, and 18.7% on ti-base height. The majority of the included studies were associated with a medium risk of bias. In the absence of micro-retentive features, air-abrasion of ti-bases with a minimum height of 3.5 mm can be beneficial for restoration's retention. The bonding performance can vary not only between different bonding systems but also for different applications within the same system, based on a restoration's material and surface treatment as well as on ti-base height and surface treatment. Conclusions: The height of the ti-base seems to be the prevailing factor as it constitutes the prerequisite for other modifications of the bonding surfaces to have an advantageous effect. Since the parameters that can affect bonding performance between ti-base and restoration can interact with each other, it is important for the clinician to focus on verified bonding protocols.
引用
收藏
页码:1203 / 1225
页数:23
相关论文
共 42 条
  • [1] Mechanical Assessment of CAD/CAM Fabricated Hybrid Ceramics: An In Vitro Study
    Alanazi, Khalid K.
    Alzaid, Abdulaziz A.
    Elkaffas, Ali A.
    Bukhari, Sarah A.
    Althubaitiy, Ramzi O.
    Alfaifi, Khalid A.
    Alfahdi, Ibrahim M.
    Alqahtani, Hussain A.
    APPLIED SCIENCES-BASEL, 2024, 14 (17):
  • [2] Mechanical stability and technical outcomes of monolithic CAD/CAM fabricated abutment-crowns supported by titanium bases: An in vitro study
    Pitta, Joao
    Hjerppe, Jenni
    Burkhardt, Felix
    Fehmer, Vincent
    Mojon, Philippe
    Sailer, Irena
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (02) : 222 - 232
  • [3] In vitro fit of CAD-CAM complete arch screw-retained titanium and zirconia implant prostheses fabricated on 4 implants
    AL-Meraikhi, Hadi
    Yilmaz, Burak
    McGlumphy, Edwin
    Brantley, William
    Johnston, William M.
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (03): : 409 - 416
  • [4] CAD/CAM-fabricated implant-supported restorations: a systematic review
    Patzelt, Sebastian Berthold Maximilian
    Spies, Benedikt C.
    Kohal, Ralf J.
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 : 77 - 85
  • [5] Influence of cementation on in vitro performance, marginal adaptation and fracture resistance of CAD/CAM-fabricated ZLS molar crowns
    Preis, Verena
    Behr, Michael
    Hahnel, Sebastian
    Rosentritt, Martin
    DENTAL MATERIALS, 2015, 31 (11) : 1363 - 1369
  • [6] Marginal and Internal Fit of Ceramic Prostheses Fabricated from Different Chairside CAD/CAM Systems: An In Vitro Study
    Son, Keunbada
    Lee, Kyu-Bok
    APPLIED SCIENCES-BASEL, 2021, 11 (02): : 1 - 13
  • [7] Evaluation of the adaptation of complete denture metal bases fabricated with dental CAD-CAM systems: An in vitro study
    You, Seung-Gyu
    You, Seung-Min
    Kang, Seen-Young
    Bae, So-Yeon
    Kim, Ji-Hwan
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (03): : 479 - 485
  • [8] Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Auricular Prostheses-Systematic Review
    Tanveer, Waqas
    Ridwan-Pramana, Angela
    Molinero-Mourelle, Pedro
    Forouzanfar, Tymour
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (18)
  • [9] Systematic Review of Clinical Applications of CAD/CAM Technology for Craniofacial Implants Placement and Manufacturing of Nasal Prostheses
    Tanveer, Waqas
    Ridwan-Pramana, Angela
    Molinero-Mourelle, Pedro
    Koolstra, Jan Harm
    Forouzanfar, Tymour
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (07)
  • [10] Biomechanical behavior of all-ceramic endocrowns fabricated using CAD/CAM: A systematic review
    AlHelal, Abdulaziz A.
    JOURNAL OF PROSTHODONTIC RESEARCH, 2024, 68 (01) : 50 - 62