In vitro assessment of cementation of CAD/CAM fabricated prostheses over titanium bases. A systematic review

被引:1
|
作者
Ntovas, Panagiotis [1 ]
Ladia, Ourania [2 ]
Pachiou, Aspasia [2 ]
Fehmer, Vincent [3 ]
Sailer, Irena [3 ]
机构
[1] Tufts Univ, Sch Dent Med, Dept Prosthodont, 630 Washington St, Boston, MA 02111 USA
[2] Natl & Kapodistrian Univ Athens, Sch Dent, Dept Prosthodont, Athens, Greece
[3] Univ Clin Dent Med, Univ Geneva, Div Fixed Prosthodont & Biomat, Geneva, Switzerland
关键词
CAD/CAM; de-bonding; hybrid abutment; implant prosthesis; implant-supported crown; systematic review; titanium-based abutment; FIXED DENTAL PROSTHESES; IMPLANT ABUTMENTS; COMPLICATION RATES; SURFACE TREATMENTS; CLINICAL-TRIAL; SINGLE CROWNS; SURVIVAL; RESTORATIONS; RETENTION; INTERFACE;
D O I
10.1111/clr.14347
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The objective of this study is to investigate the outcomes of clinically relevant laboratory studies regarding the cementation of implant-supported restorations over ti-bases. Materials and Methods: The present study has been conducted according to PRISMA statement. An electronic search was performed, including publications up to March 2024, to identify studies investigating the parameters affecting the cementation between ti-bases and CAD/CAM prostheses. An assessment of the internal validity was performed, using a custom-made risk of bias tool (QUIN). Results: From the included studies, 40.1% were reported on luting systems, 25% on ti-base surface treatment, 25% on restoration surface, 21.8% on restoration material, and 18.7% on ti-base height. The majority of the included studies were associated with a medium risk of bias. In the absence of micro-retentive features, air-abrasion of ti-bases with a minimum height of 3.5 mm can be beneficial for restoration's retention. The bonding performance can vary not only between different bonding systems but also for different applications within the same system, based on a restoration's material and surface treatment as well as on ti-base height and surface treatment. Conclusions: The height of the ti-base seems to be the prevailing factor as it constitutes the prerequisite for other modifications of the bonding surfaces to have an advantageous effect. Since the parameters that can affect bonding performance between ti-base and restoration can interact with each other, it is important for the clinician to focus on verified bonding protocols.
引用
收藏
页码:1203 / 1225
页数:23
相关论文
共 42 条
  • [41] Effect of different finish line preparations on the marginal and internal adaptation of cobalt-chromium metal alloy copings fabricated by using CAD-CAM technology: A systematic review and meta-analysis
    Shah, Naisargi
    Badwaik, Praveen
    Sheth, Vidhi H.
    Bhatnagar, Vishrut
    Bhanushali, Nikhil
    Patil, Prashant
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (05): : 716 - +
  • [42] Do CAD-CAM fibre posts exhibit higher bond strength and fracture resistance than other types of posts? systematic review with network meta-analysis of in-vitro studies
    Ghanem, Mohammed Maher
    Leong, Xin Yi
    Veettil, Sajesh K.
    Al Jada, Anas
    Saeed, Musab
    Menon, Rohit Kunnath
    BDJ OPEN, 2025, 11 (01)