In Vitro Fatigue and Fracture Load of Monolithic Ceramic Crowns Supported by Hybrid Abutment

被引:0
|
作者
Nawafleh, Noor [1 ]
Elshiyab, Shareen [1 ]
Ochsner, Andreas [2 ,3 ]
George, Roy [4 ]
机构
[1] Jordan Univ Sci & Technol, Fac Appl Med Sci, Irbid 22110, Jordan
[2] Esslingen Univ Appl Sci, Fac Mech Engn, Esslingen, Germany
[3] Univ Newcastle, Fac Engn & Built Environm, Newcastle, NSW, Australia
[4] Griffith Univ, Sch Dent & Oral Hlth, Gold Coast, Qld, Australia
来源
OPEN DENTISTRY JOURNAL | 2021年 / 15卷
关键词
Chewing simulation; Fatigue; Fracture resistance; Lithium disilicate; Zirconia; Hybrid abutment; Dental implant; FIXED DENTAL PROSTHESES; LITHIUM DISILICATE CROWNS; ZIRCONIA-BASED CROWNS; MEAN FOLLOW-UP; SINGLE CROWNS; CLINICAL-EVALUATION; PREPARATION DESIGNS; CAD/CAM-MATERIALS; SURVIVAL RATES; MOLAR CROWNS;
D O I
10.2174/1874210602115010664
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: This study evaluated the performance of zirconia and lithium disilicate crowns supported by implants or cemented to epoxy resin dies. Methods: Eigthy zirconia and lithium disilicate crowns each were prepared and assigned in four groups according to the crown material and supporting structure combinations (implant-supported zirconia, die-supported zirconia, implant-supported lithium disilicate, and die-supported lithium disilicate). Ten crowns in each group acted as control while the rest (n=10) underwent thermocycling and fatigue with 100 N loading force for 1.5 million cycles. Specimens were then loaded to fracture in a universal testing machine. Data were analysed using one-way ANOVA and Tukey multiple comparison test with a 95% level of significance. Results: No implants or crown failure occurred during fatigue. The mean fracture load values (control, fatigued) in newton Were as follows: (4054, 3344) for implant-supported zirconia, (3783, 3477) for die-supported zirconia, (2506, 2207) for implant-supported lithium disilicate, and (2159, 1806) for die-supported lithium disilicate. Comparing the control with the corresponding fatigued subgroup showed a significantly higher fracture load mean of the control group in all cases. Zirconia showed a significantly higher fracture load mean than lithium disilicate (P=0.001, P<0.001). However, comparing crowns made from the same material according to the supporting structure showed no significant difference (P=0.923, P=0.337). Conclusion: Zirconia and lithium disilicate posterior crowns have adequate fatigue and fracture resistance required for posterior crowns. However, when heavy fatigue forces are expected, zirconia material is preferable over lithium disilicate. Zirconia and lithium disilicate implant-supported crowns cemented to hybrid abutments should have satisfactory clinical performance.
引用
收藏
页码:664 / 671
页数:8
相关论文
共 50 条
  • [1] In Vitro Fatigue and Fracture Testing of Implant-Supported Anterior Ceramic Crowns
    Preis, Verena
    Behr, Michael
    Rosentritt, Martin
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (03) : 264 - 266
  • [2] In vitro fracture load of monolithic lithium disilicate ceramic molar crowns with different wall thicknesses
    Seydler, Bodo
    Rues, Stefan
    Mueller, Denise
    Schmitter, Marc
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (04) : 1165 - 1171
  • [3] In vitro fracture load of monolithic lithium disilicate ceramic molar crowns with different wall thicknesses
    Bodo Seydler
    Stefan Rues
    Denise Müller
    Marc Schmitter
    Clinical Oral Investigations, 2014, 18 : 1165 - 1171
  • [4] Influence of monolithic restorative materials on the implant- abutment interface of hybrid abutment crowns: An in vitro investigation
    Graf, Tobias
    Schweiger, Josef
    Stimmelmayr, Michael
    Erdelt, Kurt
    Schubert, Oliver
    Gueth, Jan-Frederik
    JOURNAL OF PROSTHODONTIC RESEARCH, 2023, 67 (03) : 450 - 459
  • [5] Monolithic hybrid abutment crowns (screw-retained) versus monolithic hybrid abutments with adhesively cemented monolithic crowns
    Naumann, Michael
    Scholz, Patricia
    Krois, Joachim
    Schwendicke, Falk
    Sterzenbach, Guido
    Happe, Arndt
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (03) : 209 - 220
  • [6] In vitro fracture and fatigue resistance of monolithic zirconia crowns fabricated by stereolithography
    Zhai, Zidi
    Qian, Chao
    Jiao, Ting
    Sun, Jian
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (02): : 584 - 591
  • [7] Fracture Load of Monolithic CAD/CAM Ceramic Crowns Placed on Different Implant Abutments
    Meneghetti, Priscila Ceolin
    Pittas do Canto, Paulo Eduardo
    Spohr, Ana Maria
    Burnett Junior, Luiz Henrique
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (06) : 1217 - 1222
  • [8] Effect of occlusal groove on abutment, crown thickness, and cement-type on fracture load of monolithic zirconia crowns
    Tsuyuki, Yu
    Sato, Toru
    Nomoto, Syuntaro
    Yotsuya, Mamoru
    Koshihara, Teruyoshi
    Takemoto, Shinji
    Yoshinari, Masao
    DENTAL MATERIALS JOURNAL, 2018, 37 (05) : 843 - 850
  • [9] Fracture Load of Monolithic CAD/CAM Lithium Disilicate Ceramic Crowns and Veneered Zirconia Crowns as a Posterior Implant Restoration
    Kim, Jee Hwan
    Lee, Su-Jeong
    Park, Jun Sub
    Ryu, Jae Jun
    IMPLANT DENTISTRY, 2013, 22 (01) : 66 - 70
  • [10] Influence of Abutment Design on Stiffness, Strength, and Failure of Implant-Supported Monolithic Resin Nano Ceramic (RNC) Crowns
    Joda, Tim
    Huber, Samuel
    Buerki, Alexander
    Zysset, Philippe
    Braegger, Urs
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (06) : 1200 - 1207