Dosimetry of small beams used in radiosurgery: A comparison between different detectors and Monte Carlo simulation

被引:0
|
作者
Francescon, P [1 ]
Cavedon, C [1 ]
Cora, S [1 ]
Stancanello, J [1 ]
Scalchi, P [1 ]
Avanzo, M [1 ]
机构
[1] Osped San Bortolo, Vicenza, Italy
关键词
D O I
10.1118/1.1997966
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare experimental results from different detectors to Monte Carlo simulation in the dosimetry of small fields employed in the Cyberknife radiosurgery system. The Monte Carlo code has also been used to decide whether protocols that require a 10×10 cm2 field can be used for dosimetry under reference conditions. Method and Materials: Total scatter factors (sc,p) have been measured by means of the PTW PinPoint, Exradin A16 and T14P microchambers, Thomson and Nielsen micromosfet, PTW diamond and diode detectors, and MD 55‐2 radiochromic films. A Monte Carlo calculation (BEAM code) was used to simulate the Cyberknife linac and to calculate sc,p and correction factors to be applied to raw data for various detectors. Two Farmer‐type chambers were also simulated in order to calculate the ratio between kQ factors for the Cyberknife and of for a standard 6MV linac. Results: Monte Carlo simulations gave results in agreement within ±1% with experimental results for sc,p, PDD and profiles for collimators above 10 mm. Results for sc,p of smaller collimators (5 to 10 mm) agreed with radiochromic film measurements within ± 2%, while results with ionization chambers and diamond suffer from a systematic underestimation, resolved after application of the Monte Carlo correction factor. Micro‐mosfet detectors showed good results as compared to Monte Carlo and radiochromic films, but suffered from poor reproducibility. The PTW diode detector seemed to systematically overestimate sc,p values; for the 5 mm collimator, a value of 0.746 has been obtained versus values in the range 0.67–0.71 obtained with Monte Carlo, radiochromic films, ionization chambers and diamond. The ratio between kQ factors at different beam qualities is 1.002 ± 0.5%. Conclusion: Monte Carlo can be used in the dosimetry of small beams to help solve experimental problems due to the finite dimension and to non‐water equivalence of the detectors. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2004 / 2004
页数:1
相关论文
共 50 条
  • [41] Uncertainties of Monte Carlo simulation for brachytherapy source dosimetry
    Rachabatthula, V
    Meigooni, A
    MEDICAL PHYSICS, 2004, 31 (06) : 1732 - 1732
  • [42] Considerations on the miniaturization of detectors for in vivo dosimetry in radiotherapy: A Monte Carlo study
    Cunha, Micaela
    Testa, Etienne
    Beuve, Michael
    Balosso, Jacques
    Chaikh, Abdulhamid
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2017, 399 : 20 - 27
  • [43] A Monte Carlo approach for small electron beam dosimetry
    Rincón, M
    Sánchez-Doblado, F
    Perucha, M
    Leal, A
    Arráns, R
    Carrasco, E
    Sánchez-Calzado, JA
    Errazquin, L
    RADIOTHERAPY AND ONCOLOGY, 2001, 58 (02) : 179 - 185
  • [44] Comparison of dosimetric characteristics between stationary and rotational gamma ray stereotactic radiosurgery systems based on Monte Carlo simulation
    Tian, Yuan
    Wang, Huidong
    Xu, Yingjie
    Yan, Hui
    Song, Yixin
    Men, Kuo
    Ma, Pan
    Ren, Xinxin
    Li, Minghui
    Zhang, Ke
    Dai, Jianrong
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2016, 2 (04):
  • [45] Monte Carlo Simulation On the Percentage Depth Dose Ratio for the Surface Dosimetry Using Tangential Photon Beams
    Chow, J.
    Grigorov, G.
    MEDICAL PHYSICS, 2008, 35 (06) : 2807 - +
  • [46] Determination of output factors for stereotactic radiosurgery beams by monte carlo and measurements
    Fan, J.
    Paskalev, K.
    Li, J.
    Wang, L.
    Chen, L.
    Price, R.
    Jin, L.
    ElDib, A.
    Ma, C.
    MEDICAL PHYSICS, 2007, 34 (06) : 2522 - 2522
  • [47] Determination of zero-field size percent depth doses and tissue maximum ratios for stereotactic radiosurgery and IMRT dosimetry: Comparison between experimental measurements and Monte Carlo simulation
    Cheng, Chee-Wai
    Cho, Sang Hyun
    Taylor, Michael
    Das, Indra J.
    MEDICAL PHYSICS, 2007, 34 (08) : 3149 - 3157
  • [48] Comparison between measurement and Monte Carlo simulation of a Bremsstrahlung source
    Stritt, N
    Jolie, J
    Materna, T
    Mondelaers, W
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY - PROCEEDINGS OF THE FOURTEENTH INTERNATIONAL CONFERENCE, PTS 1 AND 2, 1997, (392): : 253 - 256
  • [49] Monte Carlo simulations to optimize beams used in Gamma experimental dosimetry of narrow Knife radio-surgery
    Lymperopoulou, G.
    Petrokokkinos, L.
    Papagiannis, P.
    Steiner, M.
    Spevacek, V.
    Semnicka, J.
    Dvorak, P.
    Selmenis, I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 548 - 551
  • [50] Dosimetry study of 6-MV X-ray beams in stereotactic radiosurgery with BEAM/EGSnrc Monte Carlo code
    Wysocka, A
    Rostkowska, J
    Kania, M
    Bulski, W
    INTERNATIONAL JOURNAL OF CANCER, 2002, : 456 - 456