Dosimetry of small beams used in radiosurgery: A comparison between different detectors and Monte Carlo simulation

被引:0
|
作者
Francescon, P [1 ]
Cavedon, C [1 ]
Cora, S [1 ]
Stancanello, J [1 ]
Scalchi, P [1 ]
Avanzo, M [1 ]
机构
[1] Osped San Bortolo, Vicenza, Italy
关键词
D O I
10.1118/1.1997966
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare experimental results from different detectors to Monte Carlo simulation in the dosimetry of small fields employed in the Cyberknife radiosurgery system. The Monte Carlo code has also been used to decide whether protocols that require a 10×10 cm2 field can be used for dosimetry under reference conditions. Method and Materials: Total scatter factors (sc,p) have been measured by means of the PTW PinPoint, Exradin A16 and T14P microchambers, Thomson and Nielsen micromosfet, PTW diamond and diode detectors, and MD 55‐2 radiochromic films. A Monte Carlo calculation (BEAM code) was used to simulate the Cyberknife linac and to calculate sc,p and correction factors to be applied to raw data for various detectors. Two Farmer‐type chambers were also simulated in order to calculate the ratio between kQ factors for the Cyberknife and of for a standard 6MV linac. Results: Monte Carlo simulations gave results in agreement within ±1% with experimental results for sc,p, PDD and profiles for collimators above 10 mm. Results for sc,p of smaller collimators (5 to 10 mm) agreed with radiochromic film measurements within ± 2%, while results with ionization chambers and diamond suffer from a systematic underestimation, resolved after application of the Monte Carlo correction factor. Micro‐mosfet detectors showed good results as compared to Monte Carlo and radiochromic films, but suffered from poor reproducibility. The PTW diode detector seemed to systematically overestimate sc,p values; for the 5 mm collimator, a value of 0.746 has been obtained versus values in the range 0.67–0.71 obtained with Monte Carlo, radiochromic films, ionization chambers and diamond. The ratio between kQ factors at different beam qualities is 1.002 ± 0.5%. Conclusion: Monte Carlo can be used in the dosimetry of small beams to help solve experimental problems due to the finite dimension and to non‐water equivalence of the detectors. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2004 / 2004
页数:1
相关论文
共 50 条
  • [31] Monte Carlo simulation of radon SSNT detectors
    Sima, O
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 181 - 186
  • [32] Monte Carlo simulation of discrete γ-ray detectors
    Bakkali, A
    Tamda, N
    Parmentier, M
    Chavanelle, J
    Pousse, A
    Kastler, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 545 (03): : 699 - 704
  • [33] Monte Carlo simulation of hybrid pixel detectors
    Magalhaes, D. P.
    Tomal, A.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 167 (167)
  • [34] Dosimetric comparison between two MLC systems commonly used for stereotactic radiosurgery and radiotherapy: A Monte Carlo and experimental study
    Asnaashari, K.
    Chow, James C. L.
    Heydarian, Mostafa
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (04): : 350 - 356
  • [35] Comparison of CT and MRI Based Monte Carlo Simulation for Gamma Knife Stereotactic Radiosurgery
    Xiong, W.
    Huang, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [36] Improvement of small-field electron beam dosimetry using Monte Carlo simulation
    Ma, CM
    Mok, E
    Kapur, A
    Findley, D
    PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, 1997, : 159 - 162
  • [37] Comparison between a convolution based and a Monte Carlo based dosimetry tools for MRT
    Finocchiaro, D.
    Berenato, S.
    Grassi, E.
    Fioroni, F.
    Castellani, G.
    Lanconelli, N.
    Versari, A.
    Spezi, E.
    Iori, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S362 - S363
  • [38] MONTE CARLO ESTIMATION OF TOTAL SCATTER FACTORS OF SMALL PHOTON BEAMS USED IN IMRT
    Cora, S.
    Francescon, P.
    Cavedon, C.
    Scalchi, P.
    Santangelo, V.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S410 - S410
  • [39] Monte Carlo Simulation of Linear Accelerator for Dosimetry Analysis
    Francis, Seenia
    Suresh, Darshana
    Nath, Shalini
    Lakshmi, Saai D. R.
    Jayaraj, P. B.
    Puzhakkal, Niyas
    Pournami, P. N.
    2021 6TH INTERNATIONAL CONFERENCE FOR CONVERGENCE IN TECHNOLOGY (I2CT), 2021,
  • [40] IN VIVO DOSIMETRY FROM EPID AND MONTE CARLO SIMULATION
    Badel, J. N.
    Ginestet, C.
    Sarrut, D.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S386 - S386