Dosimetry of small beams used in radiosurgery: A comparison between different detectors and Monte Carlo simulation

被引:0
|
作者
Francescon, P [1 ]
Cavedon, C [1 ]
Cora, S [1 ]
Stancanello, J [1 ]
Scalchi, P [1 ]
Avanzo, M [1 ]
机构
[1] Osped San Bortolo, Vicenza, Italy
关键词
D O I
10.1118/1.1997966
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare experimental results from different detectors to Monte Carlo simulation in the dosimetry of small fields employed in the Cyberknife radiosurgery system. The Monte Carlo code has also been used to decide whether protocols that require a 10×10 cm2 field can be used for dosimetry under reference conditions. Method and Materials: Total scatter factors (sc,p) have been measured by means of the PTW PinPoint, Exradin A16 and T14P microchambers, Thomson and Nielsen micromosfet, PTW diamond and diode detectors, and MD 55‐2 radiochromic films. A Monte Carlo calculation (BEAM code) was used to simulate the Cyberknife linac and to calculate sc,p and correction factors to be applied to raw data for various detectors. Two Farmer‐type chambers were also simulated in order to calculate the ratio between kQ factors for the Cyberknife and of for a standard 6MV linac. Results: Monte Carlo simulations gave results in agreement within ±1% with experimental results for sc,p, PDD and profiles for collimators above 10 mm. Results for sc,p of smaller collimators (5 to 10 mm) agreed with radiochromic film measurements within ± 2%, while results with ionization chambers and diamond suffer from a systematic underestimation, resolved after application of the Monte Carlo correction factor. Micro‐mosfet detectors showed good results as compared to Monte Carlo and radiochromic films, but suffered from poor reproducibility. The PTW diode detector seemed to systematically overestimate sc,p values; for the 5 mm collimator, a value of 0.746 has been obtained versus values in the range 0.67–0.71 obtained with Monte Carlo, radiochromic films, ionization chambers and diamond. The ratio between kQ factors at different beam qualities is 1.002 ± 0.5%. Conclusion: Monte Carlo can be used in the dosimetry of small beams to help solve experimental problems due to the finite dimension and to non‐water equivalence of the detectors. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2004 / 2004
页数:1
相关论文
共 50 条
  • [21] Monte Carlo simulation of particle beams
    Jansen, G.H.
    Advances in Imaging and Electron Physics, 2024, 230 : 393 - 436
  • [22] Experimental characterization and Monte Carlo simulation of scintillator detectors in online electron FLASH radiotherapy dosimetry
    Morrocchi, Matteo
    Pensavalle, Jake Harold
    Ciarrocchi, Esther
    Di Martino, Fabio
    Felici, Giuseppe
    Galante, Federica
    Gasparini, Alessia
    Grasso, Luigi
    Linsalata, Stefania
    Massa, Maurizio
    Moggi, Andrea
    Pacitti, Matteo
    Vanreusel, Verdi
    Verellen, Dirk
    Bisogni, Maria Giuseppina
    JOURNAL OF INSTRUMENTATION, 2022, 17 (09)
  • [23] Cellular dosimetry of different radionuclides for targeted radionuclide therapy: Monte Carlo simulation
    Sadremomtaz, Alireza
    Masoumi, Mahboubeh
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (06):
  • [24] Monte Carlo simulation of radiation transport in inhomogeneous phantoms irradiated using stereotactic radiosurgery beams
    Cho, J
    Grein, E
    Robar, J
    Gete, E
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S90 - S90
  • [25] Monte Carlo study on IMRT and Radiosurgery dosimetry performed by ionization chamber
    Sanchez-Doblado, F
    Hartmann, GH
    Arráns, R
    Capote, R
    Pena, J
    Roselló, JV
    Leal, A
    Lagares, JI
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S120 - S120
  • [26] Monte Carlo evaluation of magnetically focused proton beams for radiosurgery
    McAuley, Grant A.
    Heczko, Sarah L.
    Nguyen, Theodore T.
    Slater, James M.
    Slater, Jerry D.
    Wroe, Andrew J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (05):
  • [27] Monte Carlo Analysis of Magnetically Focused Beams for Proton Radiosurgery
    McAuley, G. A.
    Slater, J. M.
    Heczko, S.
    Nguyen, T.
    Slater, J. D.
    Wroe, A.
    MEDICAL PHYSICS, 2017, 44 (06) : 2993 - 2993
  • [28] Monte Carlo dosimetry study of a 6 MV stereotactic radiosurgery unit
    Verhaegen, F
    Das, IJ
    Palmans, H
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10): : 2755 - 2768
  • [29] Correction Factor Measurements for Multiple Detectors Used in Small Field Dosimetry On the Varian Edge Radiosurgery System
    Tanny, S.
    Matthew, D.
    Sperling, N.
    Parsai, E.
    MEDICAL PHYSICS, 2015, 42 (06) : 3723 - 3723
  • [30] Correction factor measurements for multiple detectors used in small field dosimetry on the Varian Edge radiosurgery system
    Tanny, Sean
    Sperling, Nicholas
    Parsai, E. Ishmael
    MEDICAL PHYSICS, 2015, 42 (09) : 5370 - 5376