Improved Single Breath-Hold SSFSE Sequence for Liver MRI Based on Compressed Sensing: Evaluation of Image Quality Compared with Conventional T2-Weighted Sequences

被引:4
|
作者
Lee, Hyun Kyung [1 ,2 ,3 ]
Song, Ji Soo [1 ,2 ,3 ]
Jang, Weon [1 ,2 ,3 ]
Nickel, Dominik [4 ]
Paek, Mun Young [5 ]
机构
[1] Jeonbuk Natl Univ, Dept Radiol, Med Sch & Hosp, Jeonju 54907, South Korea
[2] Jeonbuk Natl Univ, Res Inst Clin Med, Jeonju 54907, South Korea
[3] Jeonbuk Natl Univ Hosp, Biomed Res Inst, Jeonju 54907, South Korea
[4] Siemens Healthcare, MR Applicat Predev, D-91052 Erlangen, Germany
[5] Siemens Healthineers Ltd, Seoul 03737, South Korea
关键词
magnetic resonance imaging; liver; data compression; breath holding; TURBO-SPIN-ECHO; HEPATIC ARTERIAL PHASE; MOTION CORRECTION; RECONSTRUCTION; HASTE;
D O I
10.3390/diagnostics12092164
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to evaluate the image quality of compressed-sensing accelerated single-shot fast spin-echo (SSFSECS) sequences acquired within a single breath-hold in comparison with conventional SSFSE (SSFSECONV) and multishot TSE (mTSE). A total of 101 patients who underwent liver MRI at 3 T, including SSFSECONV (acquisition time (TA) = 58-62 s), mTSE (TA = 108 s), and SSFSECS (TA = 18 s), were included in this retrospective study. Two radiologists assessed the three sequences with respect to artifacts, organ sharpness, small structure visibility, overall image quality, and conspicuity of main lesions of liver and pancreas using a five-point evaluation scale system. Descriptive statistics and the Wilcoxon signed-rank test were used for statistical analysis. SSFSECS was significantly better than SSFSECONV and mTSE for artifacts, small structure visibility, overall image quality, and conspicuity of main lesions (p < 0.005). Regarding organ sharpness, mTSE and SSFSECS did not significantly differ (p = 0.554). Conspicuity of liver lesion did not significantly differ between SSFSECONV and mTSE (p = 0.404). SSFSECS showed superior image quality compared with SSFSECONV and mTSE despite a more than three-fold reduction in TA, suggesting a remarkable potential for saving time in liver imaging.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Fast breath-hold T2-weighted MRI of the kidney by means of half-Fourier single-shot turbo spin echo: Comparison with high resolution turbo spin echo sequence
    Nakayama, Y
    Yamashita, Y
    Matsuno, Y
    Tang, Y
    Namimoto, T
    Kadota, M
    Mitsuzaki, K
    Abe, Y
    Katahira, K
    Arakawa, A
    Takahashi, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (01) : 55 - 60
  • [42] Usefulness of Breath-Hold Fat-Suppressed T2-Weighted Images With Deep Learning-Based Reconstruction of the Liver Comparison to Conventional Free-Breathing Turbo Spin Echo
    Ichinohe, Fumihito
    Oyama, Kazuki
    Yamada, Akira
    Hayashihara, Hayato
    Adachi, Yasuo
    Kitoh, Yoshihiro
    Kanki, Yusuke
    Maruyama, Katsuya
    Nickel, Marcel Dominik
    Fujinaga, Yasunari
    INVESTIGATIVE RADIOLOGY, 2023, 58 (06) : 373 - 379
  • [43] Hepatic iron deposition in patients with sickle cell disease: Role of breath-hold multiecho T2*-weighted MRI sequence
    Awad, Fatma Mohamed
    Alshazly, Shereen Ahmed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2014, 45 (03): : 651 - 655
  • [44] High-resolution 3D T2-weighted SPACE sequence with compressed sensing for the prostate gland: diagnostic performance in comparison with conventional T2-weighted images
    Moon Hyung Choi
    Young Joon Lee
    Seung Eun Jung
    Dongyeob Han
    Abdominal Radiology, 2023, 48 : 1090 - 1099
  • [45] High-resolution 3D T2-weighted SPACE sequence with compressed sensing for the prostate gland: diagnostic performance in comparison with conventional T2-weighted images
    Choi, Moon Hyung
    Lee, Young Joon
    Jung, Seung Eun
    Han, Dongyeob
    ABDOMINAL RADIOLOGY, 2023, 48 (03) : 1090 - 1099
  • [46] Fat-suppressed T2-weighted MR imaging of the liver: Comparison of respiratory triggered fast spin-echo, breath-hold single-shot fast spin-echo and breath-hold fast-recovery fast spin-echo sequences
    Katayama, M
    Masui, T
    Kobayashi, S
    Ito, T
    Sakahara, H
    Nozaki, A
    RADIOLOGY, 2000, 217 : 587 - 587
  • [47] Comparison of three free breathing T2-weighted MRI sequences in the evaluation of focal liver lesions
    Kim, Bong Soo
    Kim, Jung Hoon
    Choi, Guk Myung
    Kim, Seung Hyoung
    Park, Ji Kang
    Song, Byung-Cheol
    Kang, Weechang
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (01) : W19 - W27
  • [48] Single breath-hold T2-weighted MR imaging of the liver: Value of single-shot fast spin-echo and multishot spin-echo echoplanar imaging
    Hori, M
    Murakami, T
    Kim, T
    Kanematsu, M
    Tsuda, K
    Takahashi, S
    Takamura, M
    Hoshi, H
    Nakamura, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (05) : 1423 - 1431
  • [49] Assessment of coronary artery bypass graft patency with a 2D T2-weighted breath-hold Turbo-Spin-Echo sequence (HASTE)
    Kalden, P
    Kreitner, KF
    Wittlinger, T
    Voigtländer, T
    Krummenauer, F
    Schreiber, W
    Thelen, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (05): : 442 - 448
  • [50] T2-WEIGHTED BREATH-HOLD MR-IMAGING OF THE LIVER AT 1.5-T - RESULTS WITH A 3-DIMENSIONAL STEADY-STATE FREE PRECESSION SEQUENCE IN 87 PATIENTS
    TAUPITZ, M
    SPEIDEL, A
    HAMM, B
    DEIMLING, M
    REICHEL, M
    BOCK, A
    WOLF, KJ
    RADIOLOGY, 1995, 194 (02) : 439 - 446