Improved Single Breath-Hold SSFSE Sequence for Liver MRI Based on Compressed Sensing: Evaluation of Image Quality Compared with Conventional T2-Weighted Sequences

被引:4
|
作者
Lee, Hyun Kyung [1 ,2 ,3 ]
Song, Ji Soo [1 ,2 ,3 ]
Jang, Weon [1 ,2 ,3 ]
Nickel, Dominik [4 ]
Paek, Mun Young [5 ]
机构
[1] Jeonbuk Natl Univ, Dept Radiol, Med Sch & Hosp, Jeonju 54907, South Korea
[2] Jeonbuk Natl Univ, Res Inst Clin Med, Jeonju 54907, South Korea
[3] Jeonbuk Natl Univ Hosp, Biomed Res Inst, Jeonju 54907, South Korea
[4] Siemens Healthcare, MR Applicat Predev, D-91052 Erlangen, Germany
[5] Siemens Healthineers Ltd, Seoul 03737, South Korea
关键词
magnetic resonance imaging; liver; data compression; breath holding; TURBO-SPIN-ECHO; HEPATIC ARTERIAL PHASE; MOTION CORRECTION; RECONSTRUCTION; HASTE;
D O I
10.3390/diagnostics12092164
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to evaluate the image quality of compressed-sensing accelerated single-shot fast spin-echo (SSFSECS) sequences acquired within a single breath-hold in comparison with conventional SSFSE (SSFSECONV) and multishot TSE (mTSE). A total of 101 patients who underwent liver MRI at 3 T, including SSFSECONV (acquisition time (TA) = 58-62 s), mTSE (TA = 108 s), and SSFSECS (TA = 18 s), were included in this retrospective study. Two radiologists assessed the three sequences with respect to artifacts, organ sharpness, small structure visibility, overall image quality, and conspicuity of main lesions of liver and pancreas using a five-point evaluation scale system. Descriptive statistics and the Wilcoxon signed-rank test were used for statistical analysis. SSFSECS was significantly better than SSFSECONV and mTSE for artifacts, small structure visibility, overall image quality, and conspicuity of main lesions (p < 0.005). Regarding organ sharpness, mTSE and SSFSECS did not significantly differ (p = 0.554). Conspicuity of liver lesion did not significantly differ between SSFSECONV and mTSE (p = 0.404). SSFSECS showed superior image quality compared with SSFSECONV and mTSE despite a more than three-fold reduction in TA, suggesting a remarkable potential for saving time in liver imaging.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering
    Biederer, J
    Reuter, M
    Both, M
    Muhle, C
    Grimm, J
    Graessner, J
    Heller, M
    EUROPEAN RADIOLOGY, 2002, 12 (02) : 378 - 384
  • [32] Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering
    J. Biederer
    M. Reuter
    M. Both
    C. Muhle
    J. Grimm
    J. Graessner
    M. Heller
    European Radiology, 2002, 12 : 378 - 384
  • [33] T2-weighted MRI of the female pelvis: Comparison of breath-hold fast-recovery fast spin-echo and nonbreath-hold fast spin-echo sequences
    Masui, T
    Katayama, M
    Kobayashi, S
    Sakahara, H
    Ito, T
    Nozaki, A
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (06) : 930 - 937
  • [34] Deep learning reconstruction in pediatric brain MRI: comparison of image quality with conventional T2-weighted MRI
    Soo-Hyun Kim
    Young Hun Choi
    Joon Sung Lee
    Seul Bi Lee
    Yeon Jin Cho
    Seung Hyun Lee
    Su-Mi Shin
    Jung-Eun Cheon
    Neuroradiology, 2023, 65 : 207 - 214
  • [35] Deep learning reconstruction in pediatric brain MRI: comparison of image quality with conventional T2-weighted MRI
    Kim, Soo-Hyun
    Choi, Young Hun
    Lee, Joon Sung
    Lee, Seul Bi
    Cho, Yeon Jin
    Lee, Seung Hyun
    Shin, Su-Mi
    Cheon, Jung-Eun
    NEURORADIOLOGY, 2023, 65 (01) : 207 - 214
  • [36] Fast T2-weighted liver MR imaging: comparison among breath-hold turbo-spin-echo, HASTE, and inversion recovery (IR) HASTE sequences
    Lee, MG
    Jeong, YK
    Kim, JC
    Kang, EM
    Kim, PN
    Auh, YH
    Chien, D
    Laub, G
    ABDOMINAL IMAGING, 2000, 25 (01): : 93 - 99
  • [37] Fast T2-weighted liver MR imaging: comparison among breath-hold turbo-spin-echo, HASTE, and inversion recovery (IR) HASTE sequences
    M.-G. Lee
    Y. K. Jeong
    J. C. Kim
    E. M. Kang
    P. N. Kim
    Y. H. Auh
    D. Chien
    G. Laub
    Abdominal Imaging, 2000, 25 : 93 - 99
  • [38] Hepatic Iron Deposition in Patients With Liver Disease: Preliminary Experience With Breath-Hold Multiecho T2*-Weighted Sequence
    Chandarana, Hersh
    Lim, Ruth P.
    Jensen, Jens H.
    Hajdu, Cristina H.
    Losada, Mariela
    Babb, James S.
    Huffman, Steve
    Taouli, Bachir
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (05) : 1261 - 1267
  • [39] T2-weighted MR imaging for hepatic hemangiomas: comparison of breath-hold and non-breath-hold turbo spin-echo pulse sequences with phased-array multicoil
    T. K. Kim
    W. C. Wang
    J. K. Han
    S. G. Cho
    B. I. Choi
    Abdominal Imaging, 1998, 23 : 422 - 426
  • [40] T2-weighted MR imaging for hepatic hemangiomas: comparison of breath-hold and non-breath-hold turbo spin-echo pulse sequences with phased-array multicoil
    Kim, TK
    Wang, WC
    Han, JK
    Cho, SG
    Choi, BI
    ABDOMINAL IMAGING, 1998, 23 (04): : 422 - 426