Improved Single Breath-Hold SSFSE Sequence for Liver MRI Based on Compressed Sensing: Evaluation of Image Quality Compared with Conventional T2-Weighted Sequences

被引:4
|
作者
Lee, Hyun Kyung [1 ,2 ,3 ]
Song, Ji Soo [1 ,2 ,3 ]
Jang, Weon [1 ,2 ,3 ]
Nickel, Dominik [4 ]
Paek, Mun Young [5 ]
机构
[1] Jeonbuk Natl Univ, Dept Radiol, Med Sch & Hosp, Jeonju 54907, South Korea
[2] Jeonbuk Natl Univ, Res Inst Clin Med, Jeonju 54907, South Korea
[3] Jeonbuk Natl Univ Hosp, Biomed Res Inst, Jeonju 54907, South Korea
[4] Siemens Healthcare, MR Applicat Predev, D-91052 Erlangen, Germany
[5] Siemens Healthineers Ltd, Seoul 03737, South Korea
关键词
magnetic resonance imaging; liver; data compression; breath holding; TURBO-SPIN-ECHO; HEPATIC ARTERIAL PHASE; MOTION CORRECTION; RECONSTRUCTION; HASTE;
D O I
10.3390/diagnostics12092164
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to evaluate the image quality of compressed-sensing accelerated single-shot fast spin-echo (SSFSECS) sequences acquired within a single breath-hold in comparison with conventional SSFSE (SSFSECONV) and multishot TSE (mTSE). A total of 101 patients who underwent liver MRI at 3 T, including SSFSECONV (acquisition time (TA) = 58-62 s), mTSE (TA = 108 s), and SSFSECS (TA = 18 s), were included in this retrospective study. Two radiologists assessed the three sequences with respect to artifacts, organ sharpness, small structure visibility, overall image quality, and conspicuity of main lesions of liver and pancreas using a five-point evaluation scale system. Descriptive statistics and the Wilcoxon signed-rank test were used for statistical analysis. SSFSECS was significantly better than SSFSECONV and mTSE for artifacts, small structure visibility, overall image quality, and conspicuity of main lesions (p < 0.005). Regarding organ sharpness, mTSE and SSFSECS did not significantly differ (p = 0.554). Conspicuity of liver lesion did not significantly differ between SSFSECONV and mTSE (p = 0.404). SSFSECS showed superior image quality compared with SSFSECONV and mTSE despite a more than three-fold reduction in TA, suggesting a remarkable potential for saving time in liver imaging.
引用
收藏
页数:11
相关论文
共 50 条
  • [11] Accelerated single-shot T2-weighted fat-suppressed (FS) MRI of the liver with deep learning–based image reconstruction: qualitative and quantitative comparison of image quality with conventional T2-weighted FS sequence
    Krishna Shanbhogue
    Angela Tong
    Paul Smereka
    Dominik Nickel
    Simon Arberet
    Rebecca Anthopolos
    Hersh Chandarana
    European Radiology, 2021, 31 : 8447 - 8457
  • [12] Hepatic T2-weighted MRI: A prospective comparison of sequences, including breath-hold, half-Fourier turbo spin echo (HASTE)
    Coates, GG
    Borrello, JA
    McFarland, EG
    Mirowitz, SA
    Brown, JJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03): : 642 - 649
  • [13] Free-breathing BLADE acquisition method improves T2-weighted cardiac MR image quality compared with conventional breath-hold turbo spin-echo cartesian acquisition
    Liu, Jingjing
    Jin, Hang
    Chen, Yinyin
    Fu, Caixia
    Chen, Caizhong
    Zeng, Mengsu
    ACTA RADIOLOGICA, 2021, 62 (03) : 341 - 347
  • [14] Accelerated single-shot T2-weighted fat-suppressed (FS) MRI of the liver with deep learning-based image reconstruction: qualitative and quantitative comparison of image quality with conventional T2-weighted FS sequence
    Shanbhogue, Krishna
    Tong, Angela
    Smereka, Paul
    Nickel, Dominik
    Arberet, Simon
    Anthopolos, Rebecca
    Chandarana, Hersh
    EUROPEAN RADIOLOGY, 2021, 31 (11) : 8447 - 8457
  • [15] T2-weighted MR imaging of hepatic hemangiomas: Comparison of breath-hold and conventional turbo SE pulse sequences with the phased-array coil
    Choi, BI
    Wang, WC
    Kim, TK
    Han, JK
    Han, MC
    RADIOLOGY, 1996, 201 : 476 - 476
  • [16] COMPARISON OF BREATH-HOLD FAST SPIN-ECHO AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES FOR T2-WEIGHTED MR-IMAGING OF LIVER-LESIONS
    RYDBERG, JN
    LOMAS, DJ
    COAKLEY, KJ
    HOUGH, DM
    EHMAN, RL
    RIEDERER, SJ
    RADIOLOGY, 1995, 194 (02) : 431 - 437
  • [17] Optimizing Clinical Cardiac MRI Workflow through Single Breath-Hold Compressed Sensing Cine: An Evaluation of Feasibility and Efficiency
    Wang, Fuyan
    Zhou, Junjie
    Pu, Cailing
    Yu, Feidan
    Wu, Yan
    Zhang, Lingjie
    Ma, Siying
    Hu, Hongjie
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (03)
  • [18] T2-weighted MRI of the uterus: Fast spin echo vs. breath-hold fast spin echo
    Ascher, SM
    O'Malley, J
    Semelka, RC
    Patt, RH
    Rajan, S
    Thomasson, D
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 9 (03): : 384 - 390
  • [19] Liver: T2-weighted MR imaging with breath-hold fast-recovery optimized fast spin-echo compared with breath-hold half-Fourier and non-breath-hold respiratory-triggered fast spin-echo pulse sequences
    Augui, J
    Vignaux, O
    Argaud, C
    Coste, J
    Gouya, H
    Legmann, P
    RADIOLOGY, 2002, 223 (03) : 853 - 859
  • [20] Breath-hold fast recovery fast spin echo versus conventional non-breath-hold fast spin echo T2-weighted MR imaging of focal liver lesions
    Tseng, GY
    Thng, CH
    Wong, EH
    Tan, AGS
    Suman, P
    Quek, ST
    Ho, JTS
    Khoo, JKB
    Ooi, LLPJ
    Chow, PKH
    Chung, YFA
    Teh, CSC
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2003, 32 (04) : 450 - 454