Improved Single Breath-Hold SSFSE Sequence for Liver MRI Based on Compressed Sensing: Evaluation of Image Quality Compared with Conventional T2-Weighted Sequences

被引:4
|
作者
Lee, Hyun Kyung [1 ,2 ,3 ]
Song, Ji Soo [1 ,2 ,3 ]
Jang, Weon [1 ,2 ,3 ]
Nickel, Dominik [4 ]
Paek, Mun Young [5 ]
机构
[1] Jeonbuk Natl Univ, Dept Radiol, Med Sch & Hosp, Jeonju 54907, South Korea
[2] Jeonbuk Natl Univ, Res Inst Clin Med, Jeonju 54907, South Korea
[3] Jeonbuk Natl Univ Hosp, Biomed Res Inst, Jeonju 54907, South Korea
[4] Siemens Healthcare, MR Applicat Predev, D-91052 Erlangen, Germany
[5] Siemens Healthineers Ltd, Seoul 03737, South Korea
关键词
magnetic resonance imaging; liver; data compression; breath holding; TURBO-SPIN-ECHO; HEPATIC ARTERIAL PHASE; MOTION CORRECTION; RECONSTRUCTION; HASTE;
D O I
10.3390/diagnostics12092164
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to evaluate the image quality of compressed-sensing accelerated single-shot fast spin-echo (SSFSECS) sequences acquired within a single breath-hold in comparison with conventional SSFSE (SSFSECONV) and multishot TSE (mTSE). A total of 101 patients who underwent liver MRI at 3 T, including SSFSECONV (acquisition time (TA) = 58-62 s), mTSE (TA = 108 s), and SSFSECS (TA = 18 s), were included in this retrospective study. Two radiologists assessed the three sequences with respect to artifacts, organ sharpness, small structure visibility, overall image quality, and conspicuity of main lesions of liver and pancreas using a five-point evaluation scale system. Descriptive statistics and the Wilcoxon signed-rank test were used for statistical analysis. SSFSECS was significantly better than SSFSECONV and mTSE for artifacts, small structure visibility, overall image quality, and conspicuity of main lesions (p < 0.005). Regarding organ sharpness, mTSE and SSFSECS did not significantly differ (p = 0.554). Conspicuity of liver lesion did not significantly differ between SSFSECONV and mTSE (p = 0.404). SSFSECS showed superior image quality compared with SSFSECONV and mTSE despite a more than three-fold reduction in TA, suggesting a remarkable potential for saving time in liver imaging.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Feasibility of application of sensitivity encoding to the breath-hold T2-weighted turbo spin-echo sequence for evaluation of focal hepatic tumors
    Kim, YK
    Kim, CS
    Chung, GH
    Bin Jeon, S
    Lee, JM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) : 497 - 504
  • [23] Accelerated 3D high-resolution T2-weighted breast MRI with deep learning constrained compressed sensing, comparison with conventional T2-weighted sequence on 3.0 T
    Yang, Fan
    Pan, Xuelin
    Zhu, Ke
    Xiao, Yitian
    Yue, Xun
    Peng, Pengfei
    Zhang, Xiaoyong
    Huang, Juan
    Chen, Jie
    Yuan, Yuan
    Sun, Jiayu
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 156
  • [24] Breath-hold T2-weighted MRI of hepatic tumors: Value of echo planar imaging with diffusion-sensitizing gradient
    Okada, Y
    Ohtomo, K
    Kiryu, S
    Sasaki, Y
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (03) : 364 - 371
  • [25] Automated image quality evaluation of T2-weighted liver MRI utilizing deep learning architecture
    Esses, Steven J.
    Lu, Xiaoguang
    Zhao, Tiejun
    Shanbhogue, Krishna
    Dane, Bari
    Bruno, Mary
    Chandarana, Hersh
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 47 (03) : 723 - 728
  • [26] Breath-hold T2-weighted imaging of hepatic lesions by using fast recovery, fast spin-echo sequence
    Kim, T
    Murakami, T
    Takahashi, S
    Hori, M
    Takamura, M
    Nakamura, H
    RADIOLOGY, 2001, 221 : 304 - 305
  • [27] Fat-suppressed T2-weighted MRI of the liver: Comparison of respiratory-triggered fast spin-echo, breath-hold single-shot fast spin-echo, and breath-hold fast-recovery fast spin-echo sequences
    Katayama, M
    Masui, T
    Kobayashi, S
    Ito, T
    Takahashi, M
    Sakahara, H
    Nozaki, A
    Kabasawa, H
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) : 439 - 449
  • [28] Breath-hold High-resolution T1-weighted Gradient Echo Liver MR Imaging with Compressed Sensing Obtained during the Gadoxetic Acid-enhanced Hepatobiliary Phase: Image Quality and Lesion Visibility Compared with a Standard T1-weighted Sequence
    Ihara, Kenichiro
    Onoda, Hideko
    Tanabe, Masahiro
    Iida, Etsushi
    Ueda, Takaaki
    Kobayashi, Taiga
    Higashi, Mayumi
    Nickel, Marcel Dominik
    Imai, Hiroshi
    Ito, Katsuyoshi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2024, 23 (02) : 146 - 152
  • [29] Focal liver lesion detection and characterization with diffusion-weighted MR imaging: Comparison with standard breath-hold T2-weighted imaging
    Parikh, Tejas
    Drew, Stephen J.
    Lee, Vivian S.
    Wong, Samson
    Hecht, Elizabeth M.
    Babb, James S.
    Taouli, Bachir
    RADIOLOGY, 2008, 246 (03) : 812 - 822
  • [30] Improving the detectability of focal liver lesions on T2-weighted MR images: Ultrafast breath-hold or respiratory-triggered thin-section MRI?
    Pauleit, D
    Textor, J
    Bachmann, R
    Conrad, R
    Flacke, S
    Kreft, B
    Schild, H
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (02) : 128 - 133