A high-sensitivity large volume cryogenic detector for radon in gas

被引:7
|
作者
Wojcik, M. [1 ]
Zuzel, G. [2 ]
机构
[1] M Smoluchowski Inst Phys, PL-30059 Krakow, Poland
[2] Max Planck Inst Nucl Phys, D-69117 Heidelberg, Germany
关键词
Radon; Stainless Steel Plate; Minimum Detectable Activity; 222Rn Concentration; Cold Plate;
D O I
10.1007/s10967-008-0730-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new detector for Rn-222 measurements in gases is described. It is based on the low temperature collection of radon on a stainless steel plate and subsequent counting of emitted alpha-particles using an ion-implanted silicon detector. A very low background of 25 counts/day for the Rn-222 energy window was achieved. High detection efficiency of 32% (2 pi geometry) and the large 65 liter volume of the detector allow radon measurements at the level of 12 mBq/m(3) with 30% accuracy (relative error). Behavior of the alpha-emitting radon daughters born on the cooled stainless steel plate, Po-218 and Po-214, was also analyzed.
引用
收藏
页码:199 / 205
页数:7
相关论文
共 50 条
  • [41] PORTABLE, HIGH-SENSITIVITY RADIATION DETECTOR FOR SEARCH APPLICATIONS
    HENRY, CN
    CHAMBERS, WH
    WORTH, GM
    [J]. TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1973, 17 (NOV): : 114 - 114
  • [42] High-sensitivity photon-counting imaging detector
    Fu, LC
    Li, Y
    Duanmu, QD
    Wang, GZ
    [J]. Advanced Materials and Devices for Sensing and Imaging II, 2005, 5633 : 439 - 442
  • [43] SOFC Detector for Portable Gas Chromatography: High-sensitivity Detection of Dissolved Gases in Transformer Oil
    Fan, Jingmin
    Wang, Feng
    Sun, Qiuqin
    Bin, Feng
    Ding, Jiafeng
    Ye, Huisheng
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (05) : 2854 - 2863
  • [44] High-Sensitivity Micro-Gas Chromatograph-Photoionization Detector for Trace Vapor Detection
    Li, Maxwell Wei-Hao
    Ghosh, Abhishek
    Venkatasubramanian, Anandram
    Sharma, Ruchi
    Huang, Xiaolu
    Fan, Xudong
    [J]. ACS SENSORS, 2021, 6 (06) : 2348 - 2355
  • [45] A HIGH SENSITIVITY DETECTOR FOR GAS ANALYSIS
    WINEFORDNER, JD
    WILLIAMS, HP
    MILLER, CD
    [J]. ANALYTICAL CHEMISTRY, 1965, 37 (01) : 161 - +
  • [46] Application of high-sensitivity radon monitor on walk-in type radon calibration chamber at KRISS
    Lee, Hyun Su
    Hwang, Sanghoon
    Han, Minji
    Kim, Byoung-Chul
    Lee, Jong-Man
    Lee, Kyoung Beom
    [J]. APPLIED RADIATION AND ISOTOPES, 2024, 208
  • [47] HIGH-SENSITIVITY LASER SPECTROSCOPY WITH A GAS CELL
    BILLOWES, J
    [J]. HYPERFINE INTERACTIONS, 1990, 59 (1-4): : 3 - 12
  • [48] HIGH-SENSITIVITY RADIOASSAY BY GAS-CHROMATOGRAPHY
    KARMEN, A
    LONGO, NS
    [J]. JOURNAL OF CHROMATOGRAPHY, 1975, 112 (OCT29): : 637 - 642
  • [49] HIGH-SENSITIVITY MATERIALS FOR GAS-DETECTION
    LALAUZE, R
    PIJOLAT, C
    VINCENT, S
    BRUNO, L
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1992, 8 (03) : 237 - 243
  • [50] Small-volume and high-sensitivity NMR probes
    Martin, Gary E.
    [J]. ANNUAL REPORTS ON NMR SPECTROSCOPY, VOL 56, 2005, 56 : 1 - 96