A high-sensitivity large volume cryogenic detector for radon in gas

被引:7
|
作者
Wojcik, M. [1 ]
Zuzel, G. [2 ]
机构
[1] M Smoluchowski Inst Phys, PL-30059 Krakow, Poland
[2] Max Planck Inst Nucl Phys, D-69117 Heidelberg, Germany
关键词
Radon; Stainless Steel Plate; Minimum Detectable Activity; 222Rn Concentration; Cold Plate;
D O I
10.1007/s10967-008-0730-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new detector for Rn-222 measurements in gases is described. It is based on the low temperature collection of radon on a stainless steel plate and subsequent counting of emitted alpha-particles using an ion-implanted silicon detector. A very low background of 25 counts/day for the Rn-222 energy window was achieved. High detection efficiency of 32% (2 pi geometry) and the large 65 liter volume of the detector allow radon measurements at the level of 12 mBq/m(3) with 30% accuracy (relative error). Behavior of the alpha-emitting radon daughters born on the cooled stainless steel plate, Po-218 and Po-214, was also analyzed.
引用
收藏
页码:199 / 205
页数:7
相关论文
共 50 条
  • [11] A high-sensitivity radon emanation detector system for future low-background experiments
    Wiebe, Daniel
    Lindemann, Sebastian
    Schumann, Marc
    [J]. JOURNAL OF INSTRUMENTATION, 2024, 19 (04)
  • [12] A HIGH-SENSITIVITY DETECTION SYSTEM FOR RADON IN AIR
    HOWARD, AJ
    JOHNSON, BK
    STRANGE, WP
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 293 (03): : 589 - 595
  • [13] A HIGH-SENSITIVITY SAMPLING IR DETECTOR
    COON, DD
    GUNAPALA, SD
    KARUNASIRI, RPG
    MUEHLHOFF, HM
    [J]. INFRARED PHYSICS, 1985, 25 (1-2): : 323 - 325
  • [14] HIGH-SENSITIVITY DETECTOR OF AMINES AND THEIR DERIVATIVES
    ZANDBERG, EY
    KAMENEV, AG
    PALEEV, VI
    RASULEV, UK
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1980, 35 (06): : 799 - 803
  • [15] High-Sensitivity Miniature Smoke Detector
    Bakhoum, Ezzat G.
    [J]. IEEE SENSORS JOURNAL, 2012, 12 (10) : 3031 - 3035
  • [16] An Improved High-sensitivity Metal Detector
    Yang, Yong
    Liu, Zhi-Zhen
    Cong, Min
    [J]. INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND MECHANICAL AUTOMATION (ICEEMA 2015), 2015, : 315 - 319
  • [17] HIGH-SENSITIVITY DENSITY FLUCTUATION DETECTOR
    AZZAZY, M
    MODARRESS, D
    HOEFT, T
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1987, 20 (04): : 428 - 431
  • [18] HIGH-SENSITIVITY ACTIVATION NEUTRON DETECTOR
    ANTROPOV, SY
    ERMILOV, AP
    [J]. MEASUREMENT TECHNIQUES USSR, 1995, 38 (02): : 227 - 228
  • [19] CAPACITIVE TRANSIENT DETECTOR OF HIGH-SENSITIVITY
    ELLIS, FM
    BROOKS, JS
    HALLOCK, RB
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1981, 52 (07): : 1051 - 1053
  • [20] Development of a high-sensitivity radon monitor for a radon calibration system at KRISS
    Hwang, S. H.
    Han, M. J.
    Seon, Y. G.
    Lee, J. M.
    Lee, K. B.
    [J]. APPLIED RADIATION AND ISOTOPES, 2020, 164