SOFC Detector for Portable Gas Chromatography: High-sensitivity Detection of Dissolved Gases in Transformer Oil

被引:26
|
作者
Fan, Jingmin [1 ]
Wang, Feng [1 ]
Sun, Qiuqin [1 ]
Bin, Feng [1 ]
Ding, Jiafeng [2 ]
Ye, Huisheng [3 ]
机构
[1] Hunan Univ, Coll Elect & Informat Engn, Changsha 410082, Hunan, Peoples R China
[2] Cent South Univ, Sch Phys & Elect, Changsha 410083, Peoples R China
[3] Hunan Elect Power Corp Res Inst, State Grid, Changsha 410007, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Power transformer; Gas detectors; Chromatography; Oil insulation; Fuel cells; FAULT-DIAGNOSIS; APPARATUS;
D O I
10.1109/TDEI.2017.006438
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dissolved gas analysis (DGA) is widely used in diagnosing the incipient faults of power transformer. The detector is the key component for this method. Despite various sensors for DGA application, many of them suffer from poor stability and low sensitivity. A solid oxide fuel cell (SOFC) detector is designed in this paper to address these problems. The mechanism of the detector is briefly introduced, and it is fabricated in a mold. The test process is elucidated. For calibration purpose, two mathematical models of the detector, i.e., double-logarithmic model (DLM) and linearity model (LM), are compared with each other. Experimental results demonstrate that the SOFC detector exhibits good repeatability at given concentrations and excellent linearity with DLM. The results indicate that accurate and high-precision measurement of H-2, CH4, CO, C2H4, C2H6, and C2H2 can be achieved using the SOFC detector and the proposed DLM.
引用
收藏
页码:2854 / 2863
页数:10
相关论文
共 50 条
  • [1] The detection of dissolved gases in transformer oil by gas chromatography with helium ionization detector
    Deng Xian-qin
    Fang Hua
    Li Min-xian
    [J]. 2ND INTERNATIONAL CONFERENCE ON MEASUREMENT INSTRUMENTATION AND ELECTRONICS, 2017, 870
  • [2] SOFC Detector With OCA Approach to Quantify Trace Gases Dissolved in Transformer Oil
    Fan, Jingmin
    Lu, Yuanshen
    Ding, Jiafeng
    Meng, Anbo
    Tang, Zhenhua
    Ye, Jiazhuo
    [J]. IEEE SENSORS JOURNAL, 2020, 20 (02) : 648 - 655
  • [3] Determination of the Ostwald coefficient of dissolved gases in transformer oil with gas chromatography
    Zhao, JH
    Wang, HL
    Yang, P
    Guan, YF
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (04) : 471 - 474
  • [4] Photoacoustic detection of dissolved gases in transformer oil
    Yun, Yuxin
    Chen, Weigen
    Wang, Youyuan
    Pan, Chong
    [J]. EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2008, 18 (06): : 562 - 576
  • [5] High-Sensitivity Fiber-Optic Sensor for Hydrogen Detection in Gas and Transformer Oil
    Fisser, Maximilian
    Badcock, Rodney A.
    Teal, Paul D.
    Hunze, Arvid
    [J]. IEEE SENSORS JOURNAL, 2019, 19 (09) : 3348 - 3357
  • [6] Analysis of dissolved gases extraction processes in transformer oil for chromatography
    Darian, L. A.
    Korobeynikov, S. M.
    [J]. IFOST: 2007 INTERNATIONAL FORUM ON STRATEGIC TECHNOLOGY, 2007, : 261 - 264
  • [7] PORTABLE, HIGH-SENSITIVITY RADIATION DETECTOR FOR SEARCH APPLICATIONS
    HENRY, CN
    CHAMBERS, WH
    WORTH, GM
    [J]. TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1973, 17 (NOV): : 114 - 114
  • [8] Development of a High-Sensitivity Radiation Detector for Chromatography
    Huber, Jennifer S.
    Hanrahan, Stephen M.
    Moses, William W.
    Derenzo, Steve E.
    Reutter, Bryan W.
    O'Neil, James P.
    Gullberg, Grant T.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (03) : 1241 - 1248
  • [9] GAS-CHROMATOGRAPHIC ANALYSIS OF DISSOLVED GASES IN TRANSFORMER OIL
    WATANABE, C
    YANAGISAWA, N
    KUBO, Y
    [J]. BUNSEKI KAGAKU, 1975, 24 (12) : 737 - 741
  • [10] Development of a High-Sensitivity Radiation Detector for Chromatography
    Huber, J. S.
    Hanrahan, S. M.
    Moses, W. W.
    Derenzo, S. E.
    Reutter, B. W.
    O'Neil, J. P.
    Gullberg, G. T.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2620 - 2624