SOFC Detector for Portable Gas Chromatography: High-sensitivity Detection of Dissolved Gases in Transformer Oil

被引:29
|
作者
Fan, Jingmin [1 ]
Wang, Feng [1 ]
Sun, Qiuqin [1 ]
Bin, Feng [1 ]
Ding, Jiafeng [2 ]
Ye, Huisheng [3 ]
机构
[1] Hunan Univ, Coll Elect & Informat Engn, Changsha 410082, Hunan, Peoples R China
[2] Cent South Univ, Sch Phys & Elect, Changsha 410083, Peoples R China
[3] Hunan Elect Power Corp Res Inst, State Grid, Changsha 410007, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Power transformer; Gas detectors; Chromatography; Oil insulation; Fuel cells; FAULT-DIAGNOSIS; APPARATUS;
D O I
10.1109/TDEI.2017.006438
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dissolved gas analysis (DGA) is widely used in diagnosing the incipient faults of power transformer. The detector is the key component for this method. Despite various sensors for DGA application, many of them suffer from poor stability and low sensitivity. A solid oxide fuel cell (SOFC) detector is designed in this paper to address these problems. The mechanism of the detector is briefly introduced, and it is fabricated in a mold. The test process is elucidated. For calibration purpose, two mathematical models of the detector, i.e., double-logarithmic model (DLM) and linearity model (LM), are compared with each other. Experimental results demonstrate that the SOFC detector exhibits good repeatability at given concentrations and excellent linearity with DLM. The results indicate that accurate and high-precision measurement of H-2, CH4, CO, C2H4, C2H6, and C2H2 can be achieved using the SOFC detector and the proposed DLM.
引用
收藏
页码:2854 / 2863
页数:10
相关论文
共 50 条
  • [21] HIGH-SENSITIVITY OPTICAL RESOLUTION OF AMINES BY GAS CHROMATOGRAPHY
    HALPERN, B
    WESTLEY, JW
    CHEMICAL COMMUNICATIONS, 1966, (02) : 34 - &
  • [22] HIGH-SENSITIVITY MATERIALS FOR GAS-DETECTION
    LALAUZE, R
    PIJOLAT, C
    VINCENT, S
    BRUNO, L
    SENSORS AND ACTUATORS B-CHEMICAL, 1992, 8 (03) : 237 - 243
  • [23] HIGH-SENSITIVITY DETECTION OF AMINO-ACIDS BY GAS CHROMATOGRAPHY AND ELECTRON AFFINITY SPECTROMETRY
    LANDOWNE, RA
    LIPSKY, SR
    NATURE, 1963, 199 (488) : 141 - +
  • [24] A high-sensitivity large volume cryogenic detector for radon in gas
    Wojcik, M.
    Zuzel, G.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 277 (01) : 199 - 205
  • [25] A high-sensitivity large volume cryogenic detector for radon in gas
    M. Wojcik
    G. Zuzel
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 277 : 199 - 205
  • [26] Practical Experience of Dissolved Gas in Transformer Oil for the Detection of Incipient Faults
    Ding, Hongzhi
    Heywood, Richard
    Lapworth, John
    Josebury, Richard
    Roxborough, Andrew
    McCulloch, Elaine
    2017 IEEE 19TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS (ICDL), 2017,
  • [27] High-sensitivity laser-based photothermal detector for liquid chromatography
    Vladykin, GB
    Aratskova, AA
    Yashin, YI
    ZHURNAL FIZICHESKOI KHIMII, 1997, 71 (08): : 1497 - 1499
  • [28] Development of an Online Detection Setup for Dissolved Gas in Transformer Insulating Oil
    Chen, Yang
    Wang, Zhentao
    Li, Zhao
    Zheng, Hongquan
    Dai, Jingmin
    APPLIED SCIENCES-BASEL, 2021, 11 (24):
  • [29] High-Sensitivity Micro-Gas Chromatograph-Photoionization Detector for Trace Vapor Detection
    Li, Maxwell Wei-Hao
    Ghosh, Abhishek
    Venkatasubramanian, Anandram
    Sharma, Ruchi
    Huang, Xiaolu
    Fan, Xudong
    ACS SENSORS, 2021, 6 (06) : 2348 - 2355
  • [30] High sensitivity portable neutron detector for fissile materials detection
    Athanasiades, Athanasios
    Shehad, Nader N.
    Sun, Liang
    Lyons, Tom D.
    Martin, Christopher S.
    Bu, Lu
    Lacy, Jeffrey L.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1009 - 1013