Analysis of dissolved gases extraction processes in transformer oil for chromatography

被引:2
|
作者
Darian, L. A. [1 ]
Korobeynikov, S. M. [1 ]
机构
[1] Novosibirsk State Tech Univ, Novosibirsk 630092, Russia
关键词
D O I
10.1109/IFOST.2007.4798577
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The main diffusion processes that are in devices for testing of transformer oil for gas chromatography are considered. The estimation of time for safety storage of most movable gas in transformer oil - hydrogen in several types of syringe, is shown. It is obtained that the most suitable device is "Elchrom", where used both glass frame of syringe and glass plunger. Besides it has PTFE sealing gasket that lead to the safety of the gas in probing during more than one month. The equilibration time for gas in oil and gas in gas phase is estimated for some devices of gas extraction.
引用
收藏
页码:261 / 264
页数:4
相关论文
共 50 条
  • [1] Analysis and Interpretation of Dissolved Gases in Transformer Oil
    Hettiwatte, S. N.
    Fonseka, H. A.
    [J]. PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 35 - 38
  • [2] Determination of the Ostwald coefficient of dissolved gases in transformer oil with gas chromatography
    Zhao, JH
    Wang, HL
    Yang, P
    Guan, YF
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (04) : 471 - 474
  • [3] GAS-CHROMATOGRAPHIC ANALYSIS OF DISSOLVED GASES IN TRANSFORMER OIL
    WATANABE, C
    YANAGISAWA, N
    KUBO, Y
    [J]. BUNSEKI KAGAKU, 1975, 24 (12) : 737 - 741
  • [4] Quantitative Analysis of Transformer Oil Dissolved Gases Using FTIR
    Zhao An-xin
    Tang Xiao-jun
    Wang Er-zhen
    Zhang Zhong-hua
    Liu Jun-hua
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (09) : 2407 - 2410
  • [5] The detection of dissolved gases in transformer oil by gas chromatography with helium ionization detector
    Deng Xian-qin
    Fang Hua
    Li Min-xian
    [J]. 2ND INTERNATIONAL CONFERENCE ON MEASUREMENT INSTRUMENTATION AND ELECTRONICS, 2017, 870
  • [6] Analysis of infrared absorption properties of dissolved gases in transformer oil
    Chen, Wei-Gen
    Yun, Yu-Xin
    Pan, Chong
    Sun, Cai-Xin
    [J]. Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2008, 28 (16): : 148 - 153
  • [7] Photoacoustic detection of dissolved gases in transformer oil
    Yun, Yuxin
    Chen, Weigen
    Wang, Youyuan
    Pan, Chong
    [J]. EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2008, 18 (06): : 562 - 576
  • [8] On Machine Learning Apporaches towards Dissolved Gases Analyses of Power Transformer Oil Chromatography
    Su, Lei
    Yang, Yixuan
    Xing, Haobo
    Wei, Bengang
    Ling, Ping
    Lu, Wenlian
    [J]. 2019 IEEE SYMPOSIUM SERIES ON COMPUTATIONAL INTELLIGENCE (IEEE SSCI 2019), 2019, : 1743 - 1750
  • [9] Characteristics of Tin Oxide Chromatographic Detector for Dissolved Gases Analysis of Transformer Oil
    Fan, Jingmin
    Liu, Zhe
    Meng, Anbo
    Yin, Hao
    Sun, Qiuqin
    Bin, Feng
    Jiang, Qinji
    [J]. IEEE ACCESS, 2019, 7 : 94012 - 94020
  • [10] Parallelization Analysis of Dissolved Gases in Transformer Oil Based on Random Forest Algorithm
    Wang, Dewen
    Sun, Zhiwei
    [J]. COMPUTER AND INFORMATION TECHNOLOGY, 2014, 519-520 : 98 - 101