Clinical and functional outcomes after type B-C (AO/OTA) distal humeral fractures treated with locking compression plates: a retrospective study

被引:1
|
作者
Citarelli, Carmine [1 ]
Sacchetti, Federico [1 ]
Agostini, Giulio [1 ]
Mattugini, Vittorio [1 ]
Andreani, Lorenzo [1 ]
Carmassi, Fabio [1 ]
Scaglione, Michelangelo [1 ]
Capanna, Rodolfo [1 ]
机构
[1] Univ Pisa, Unit Orthoped, Pisa, Italy
来源
MINERVA ORTHOPEDICS | 2021年 / 72卷 / 04期
关键词
Humerus; Fractures; bone; Retrospective studies; Locking compression plates; OPERATIVE TREATMENT; OLDER;
D O I
10.23736/S2784-8469.20.04002-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BACKGROUND: B-C (AO/OTA) fractures of distal humerus are lesions difficult to treat with results that are not always satisfactory. The aim of this study was to evaluate the outcome of patients with this type of fractures treated at our institute. METHODS: A retrospective study considering 32 patients with mean age of 57.1 years (19-85) treated with open reduction and internal fixation (ORIF) for distal humerus articular fractures, 5 type B1. 1 type B2, 12 type C1, 4 type C2, 10 type C3 (AO/OTA), 29 closed fractures, 2 with grade I-II (Gustillo) of exposure, 1 with point exposure. Surgical exposures used are triceps-on and olecranon osteotomy, while the synthesis was performed with locking compression plates. The average follow-up was 42.7 months (79-9). The radiograms performed during the standard controls were evaluated and the Mayo Elbow Performance Score was used for functional evaluation. RESULTS: Average MEPS of 90.6 (55-100), excellent in 68.8%, good 18.7%, fair, 6.3% and poor 6.3%. Average flexion of 125.1 degrees(40-140 degrees) with an average deficiency of 11 degrees (0-40 degrees). All olecranial osteotomies healed, no pseudoarthrosis was found. Registered complications: 2 wound dehiscences, 7 cases with residual hypoesthesia in the territory of the ulnar nerve, 1 mobilization of a healed fracture screw, 3 cases with presence of joint ossifications and marked rigidity with subsequent surgical revision. CONCLUSIONS: ORIF with orthogonal construct and locking compression plates is an optimal technique for the treatment of distal humerus articular fractures. Associated with an early mobilization leads to an excellent functional result with a minimum rate of complications.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 50 条
  • [41] Results of type C fractures of distal radius treated by volar locking plate (VLP), an observational comparative study
    Lv, Zhenmu
    Zhao, Yan
    Zhang, Yingze
    Wang, Qiusheng
    Ding, Wenyuan
    Shen, Yong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (10): : 14721 - 14729
  • [42] Results of dorsal or volar plate fixation of AO type C3 distal radius fractures: A retrospective study
    Rein, Susanne
    Schikore, Hartmut
    Schneiders, Wolfgang
    Amlang, Michael
    Zwipp, Hans
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (07): : 954 - 961
  • [43] Volar locking plate versus K-wire-supported external fixation in the treatment of AO/ASIF type C distal radius fractures: A comparison of functional and radiological outcomes
    Duramaz, Altug
    Bilgili, Mustafa Gokhan
    Karaali, Evren
    Bayram, Berhan
    Ziroglu, Nezih
    Kural, Cemal
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2018, 24 (03): : 255 - 262
  • [44] Anteroinferior 2.7-mm Versus 3.5-mm Plating for AO/OTA Type B Clavicle Fractures: A Comparative Cohort Clinical Outcomes Study
    Galdi, Balazs
    Yoon, Richard S.
    Choung, Edward W.
    Reilly, Mark C.
    Sirkin, Michael
    Smith, Wade R.
    Liporace, Frank A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2013, 27 (03) : 121 - 125
  • [45] Stability of volar locking plate systems for AO type C3 fractures of the distal radius: biomechanical study in a cadaveric model
    Kamei, Shuzo
    Osada, Denju
    Tamai, Kazuya
    Kato, Nakayuki
    Takai, Morimitsu
    Kameda, Masahiro
    Nohara, Yutaka
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2010, 15 (03) : 357 - 364
  • [46] Volar Locking Plate Compared With Combined Plating of AO Type C Distal Radius Fractures: A Randomized Controlled Study of 150 Cases
    Lundqvist, Eva
    Fischer, Per
    Wretenberg, Per
    Pettersson, Kurt
    Personat, Adolfo Lopez
    Sagerfors, Marcus
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (09): : 813 - 822
  • [47] Number of screws in the articular segment of distal humerus AO/OTA C-type fractures treated with open reduction internal fixation is associated with complication rate
    Grogan, Brian F.
    Danford, Nicholas C.
    Lopez, Cesar D.
    Maier, Stephen P., II
    Kongmalai, Pinkawas
    Kovacevic, David
    Levine, William N.
    Jobin, Charles M.
    SICOT-J, 2021, 7
  • [48] A RANDOMISED CLINICAL STUDY COMPARING PALMAR AND DORSAL FIXED-ANGLE PLATES FOR THE INTERNAL FIXATION OF AO C-TYPE FRACTURES OF THE DISTAL RADIUS IN THE ELDERLY
    Jakubietz, R. G.
    Gruenert, J. G.
    Kloss, D. F.
    Schindele, S.
    Jakurietz, M. G.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2008, 33E (05) : 600 - 604
  • [49] Letter Regarding "Biomechanical Comparison of Volar Fixed-Angle Locking Plates for AO C3 Distal Radius Fractures: Titanium Versus Stainless Steel With Compression"
    Spiegel, Adrian
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2016, 41 (07): : E225 - E225
  • [50] Clinical and radiologic factors affecting functional outcomes after volar locking plate fixation of dorsal angulated distal radius fractures
    Lee, Seoung-Joon
    Park, Jong Woong
    Kang, Byeong Jik
    Lee, Jung Il
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2016, 21 (05) : 619 - 624