Clinical and functional outcomes after type B-C (AO/OTA) distal humeral fractures treated with locking compression plates: a retrospective study

被引:1
|
作者
Citarelli, Carmine [1 ]
Sacchetti, Federico [1 ]
Agostini, Giulio [1 ]
Mattugini, Vittorio [1 ]
Andreani, Lorenzo [1 ]
Carmassi, Fabio [1 ]
Scaglione, Michelangelo [1 ]
Capanna, Rodolfo [1 ]
机构
[1] Univ Pisa, Unit Orthoped, Pisa, Italy
来源
MINERVA ORTHOPEDICS | 2021年 / 72卷 / 04期
关键词
Humerus; Fractures; bone; Retrospective studies; Locking compression plates; OPERATIVE TREATMENT; OLDER;
D O I
10.23736/S2784-8469.20.04002-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BACKGROUND: B-C (AO/OTA) fractures of distal humerus are lesions difficult to treat with results that are not always satisfactory. The aim of this study was to evaluate the outcome of patients with this type of fractures treated at our institute. METHODS: A retrospective study considering 32 patients with mean age of 57.1 years (19-85) treated with open reduction and internal fixation (ORIF) for distal humerus articular fractures, 5 type B1. 1 type B2, 12 type C1, 4 type C2, 10 type C3 (AO/OTA), 29 closed fractures, 2 with grade I-II (Gustillo) of exposure, 1 with point exposure. Surgical exposures used are triceps-on and olecranon osteotomy, while the synthesis was performed with locking compression plates. The average follow-up was 42.7 months (79-9). The radiograms performed during the standard controls were evaluated and the Mayo Elbow Performance Score was used for functional evaluation. RESULTS: Average MEPS of 90.6 (55-100), excellent in 68.8%, good 18.7%, fair, 6.3% and poor 6.3%. Average flexion of 125.1 degrees(40-140 degrees) with an average deficiency of 11 degrees (0-40 degrees). All olecranial osteotomies healed, no pseudoarthrosis was found. Registered complications: 2 wound dehiscences, 7 cases with residual hypoesthesia in the territory of the ulnar nerve, 1 mobilization of a healed fracture screw, 3 cases with presence of joint ossifications and marked rigidity with subsequent surgical revision. CONCLUSIONS: ORIF with orthogonal construct and locking compression plates is an optimal technique for the treatment of distal humerus articular fractures. Associated with an early mobilization leads to an excellent functional result with a minimum rate of complications.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 50 条
  • [31] Clinical and functional outcomes of locked plating vs. cerclage compression wiring for AO type C patellar fractures- a retrospective single-center cohort study
    Bickel, Steven
    Jensen, Kai Oliver
    Klingebiel, Felix Karl-Ludwig
    Teuben, Michel Paul Johan
    Pfeifer, Roman
    Pape, Hans-Christoph
    Hierholzer, Christian
    Kalbas, Yannik
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2024, 50 (06) : 2975 - 2985
  • [32] Midterm clinical and radiological outcomes of the surgical treatment of complex AO type C distal humeral fractures with two different double plate fixation techniques
    Ditsios, K.
    Stavridis, S., I
    Savvidis, P.
    Dinopoulos, H.
    Petsatodis, G.
    HIPPOKRATIA, 2017, 21 (01) : 38 - 42
  • [33] CT-Based Micromotion Analysis After Locking Plate Fixation of AO Type C Distal Radius Fractures
    Eva Lundqvist
    Henrik Olivecrona
    Per Wretenberg
    Marcus Sagerfors
    Indian Journal of Orthopaedics, 2023, 57 : 2031 - 2039
  • [34] CT-Based Micromotion Analysis After Locking Plate Fixation of AO Type C Distal Radius Fractures
    Lundqvist, Eva
    Olivecrona, Henrik
    Wretenberg, Per
    Sagerfors, Marcus
    INDIAN JOURNAL OF ORTHOPAEDICS, 2023, 57 (12) : 2031 - 2039
  • [35] STUDY OF FUNCTIONAL OUTCOME OF DISTAL FEMUR FRACTURES TREATED BY OPEN REDUCTION AND INTERNAL FIXATION WITH LOCKING COMPRESSION PLATE
    Jose, R. Sahaya
    Krishnan, N. Gopala
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (35): : 1984 - 1991
  • [36] Comparison of CFR-PEEK and conventional titanium locking plates for proximal humeral fractures: a retrospective controlled study of patient outcomes
    Padolino A.
    Porcellini G.
    Guollo B.
    Fabbri E.
    Kiran Kumar G.N.
    Paladini P.
    Merolla G.
    MUSCULOSKELETAL SURGERY, 2018, 102 (Suppl 1) : 49 - 56
  • [37] A biomechanical comparison study of a modern fibular nail and distal fibular locking plate in AO/OTA 44C2 ankle fractures
    Switaj, Paul J.
    Fuchs, Daniel
    Alshouli, Mohammed
    Patwardhan, Avinash G.
    Voronov, Leonard I.
    Muriuki, Muturi
    Havey, Robert M.
    Kadakia, Anish R.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2016, 11
  • [38] A biomechanical comparison study of a modern fibular nail and distal fibular locking plate in AO/OTA 44C2 ankle fractures
    Paul J. Switaj
    Daniel Fuchs
    Mohammed Alshouli
    Avinash G. Patwardhan
    Leonard I. Voronov
    Muturi Muriuki
    Robert M. Havey
    Anish R. Kadakia
    Journal of Orthopaedic Surgery and Research, 11
  • [39] Biomechanical Comparison of Volar Fixed-Angle Locking Plates for AO C3 Distal Radius Fractures: Titanium Versus Stainless Steel With Compression
    Marshall, Tyler
    Momaya, Amit
    Eberhardt, Alan
    Chaudhari, Nilesh
    Hunt, Thomas R., III
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (10): : 2032 - 2038
  • [40] A PROSPECTIVE STUDY ON THE OUTCOMES FOLLOWING LCP CONDYLAR PLATE FIXATION IN AO TYPE C DISTAL FEMORAL FRACTURES
    Singhal, Vikas
    Gohiya, Ashish
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (93): : 15857 - 15862