Clinical and functional outcomes after type B-C (AO/OTA) distal humeral fractures treated with locking compression plates: a retrospective study

被引:1
|
作者
Citarelli, Carmine [1 ]
Sacchetti, Federico [1 ]
Agostini, Giulio [1 ]
Mattugini, Vittorio [1 ]
Andreani, Lorenzo [1 ]
Carmassi, Fabio [1 ]
Scaglione, Michelangelo [1 ]
Capanna, Rodolfo [1 ]
机构
[1] Univ Pisa, Unit Orthoped, Pisa, Italy
来源
MINERVA ORTHOPEDICS | 2021年 / 72卷 / 04期
关键词
Humerus; Fractures; bone; Retrospective studies; Locking compression plates; OPERATIVE TREATMENT; OLDER;
D O I
10.23736/S2784-8469.20.04002-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BACKGROUND: B-C (AO/OTA) fractures of distal humerus are lesions difficult to treat with results that are not always satisfactory. The aim of this study was to evaluate the outcome of patients with this type of fractures treated at our institute. METHODS: A retrospective study considering 32 patients with mean age of 57.1 years (19-85) treated with open reduction and internal fixation (ORIF) for distal humerus articular fractures, 5 type B1. 1 type B2, 12 type C1, 4 type C2, 10 type C3 (AO/OTA), 29 closed fractures, 2 with grade I-II (Gustillo) of exposure, 1 with point exposure. Surgical exposures used are triceps-on and olecranon osteotomy, while the synthesis was performed with locking compression plates. The average follow-up was 42.7 months (79-9). The radiograms performed during the standard controls were evaluated and the Mayo Elbow Performance Score was used for functional evaluation. RESULTS: Average MEPS of 90.6 (55-100), excellent in 68.8%, good 18.7%, fair, 6.3% and poor 6.3%. Average flexion of 125.1 degrees(40-140 degrees) with an average deficiency of 11 degrees (0-40 degrees). All olecranial osteotomies healed, no pseudoarthrosis was found. Registered complications: 2 wound dehiscences, 7 cases with residual hypoesthesia in the territory of the ulnar nerve, 1 mobilization of a healed fracture screw, 3 cases with presence of joint ossifications and marked rigidity with subsequent surgical revision. CONCLUSIONS: ORIF with orthogonal construct and locking compression plates is an optimal technique for the treatment of distal humerus articular fractures. Associated with an early mobilization leads to an excellent functional result with a minimum rate of complications.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 50 条
  • [21] Long-Term Functional Outcomes and Complications of Intra-Articular (AO type B, C) Distal Humerus Fractures in Adults: A Retrospective Review
    Tyllianakis, Minos
    Solou, Konstantina
    Lakoumentas, John
    Panagopoulos, Andreas
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (01)
  • [22] STUDY OF OUTCOME OF DISTAL TIBIAL FRACTURES TREATED WITH LOCKING COMPRESSION PLATES: BY BOTH OPEN REDUCTION AND MIPO TECHNIQUE
    Nandiraju, Ravikiran
    Ramnath, D. S.
    Reddy, M. Abhinandan
    Kolla, Saketh
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (54): : 3657 - 3661
  • [23] Serial changes in the head-shaft angle of proximal humeral fractures treated by placing locking plates: a retrospective study
    Ji-Qi Wang
    Bing-Jie Jiang
    Wei-Jun Guo
    You-Ming Zhao
    BMC Musculoskeletal Disorders, 19
  • [24] Serial changes in the head-shaft angle of proximal humeral fractures treated by placing locking plates: a retrospective study
    Wang, Ji-Qi
    Jiang, Bing-Jie
    Guo, Wei-Jun
    Zhao, You-Ming
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [25] Comparative study for assessment of functional outcome of intraarticular AO Type C distal humerus fractures treated by parallel plating
    Bhayana, Himanshu
    Pandey, Rohit
    Dhammi, Ish Kumar
    Baumann, Florian
    Bhatia, Urveshi
    INDIAN JOURNAL OF ORTHOPAEDICS, 2019, 53 (01) : 190 - 195
  • [26] Clinical and Radiologic Outcomes of Volar Plate Fixation in AO Type C Distal Radius Fractures
    Senel, Ahmet
    Ozturkmen, Yusuf
    Akman, Yunus Emre
    Sukur, Erhan
    Unkar, Ethem Ayhan
    ISTANBUL MEDICAL JOURNAL, 2018, 19 (02): : 119 - 123
  • [27] Comparative Study for Assessment of Functional Outcome of Intraarticular AO Type C Distal Humerus Fractures Treated by Parallel Plating
    Himanshu Bhayana
    Rohit Pandey
    Ish Kumar Dhammi
    Florian Baumann
    Urveshi Bhatia
    Indian Journal of Orthopaedics, 2019, 53 : 190 - 195
  • [28] Functional outcomes of extra-articular scapula fracture fixation with distal humeral Y-type locking plate: a retrospective study
    Yuanjun Hu
    Huiming Shi
    Fei Wang
    Guangtie Ren
    Ruiping Cheng
    Zhizhong Zhang
    Journal of Orthopaedic Surgery and Research, 14
  • [29] Functional outcomes of extra-articular scapula fracture fixation with distal humeral Y-type locking plate: a retrospective study
    Hu, Yuanjun
    Shi, Huiming
    Wang, Fei
    Ren, Guangtie
    Cheng, Ruiping
    Zhang, Zhizhong
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (1)
  • [30] Functional Outcomes in Volar-Displaced Distal Radius Fractures Patients with Marginal Rim Fragment Treated by Volar Distal Locking Plates
    Naito, Kiyohito
    Sugiyama, Yoichi
    Kinoshita, Mayuko
    Obata, Hiroyuki
    Goto, Kenji
    Nagura, Nana
    Iwase, Yoshiyuki
    Obayashi, Osamu
    Kaneko, Kazuo
    JOURNAL OF HAND AND MICROSURGERY, 2019, 11 (02) : 100 - 105