Stability of volar locking plate systems for AO type C3 fractures of the distal radius: biomechanical study in a cadaveric model

被引:25
|
作者
Kamei, Shuzo [1 ]
Osada, Denju [1 ]
Tamai, Kazuya [1 ]
Kato, Nakayuki [1 ]
Takai, Morimitsu [1 ]
Kameda, Masahiro [1 ]
Nohara, Yutaka [1 ]
机构
[1] Dokkyo Med Univ, Sch Med, Dept Orthopaed Surg, Mibu, Tochigi 3210293, Japan
关键词
FRAGMENT-SPECIFIC FIXATION; COMPRESSION PLATE; EXTERNAL FIXATION; DORSAL; SCREW;
D O I
10.1007/s00776-010-1466-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of the present study was to compare the relative stability of five volar locking plates (all of which are available for the treatment of intraarticular fractures of the distal radius) under loading conditions simulating the physiological forces that occur during early active mobilization. Five plating techniques were applied to surgically simulated AO type C3.2 distal radius fractures in formalin-fixed cadavers. The specimens were tested with a servohydraulic materials testing machine with 250 N of axial compression load for 3000 cycles. After cyclic loading, the specimens were loaded until they demonstrated failure in axial compression. The five fixation systems studied included a DRV locking plate (group 1), a Stellar plate (group 2), an Acu-Loc plate (group 3), AO Locking Distal Radius System 2.4 (group 4); and a Matrix SmartLock plate (group 5). None of the plate fixations tested failed during the cyclic loading. Group 2 had a higher elastic limit than groups 4 and 5. There were no significant differences among the five groups for the failure load. Failure occurred at the distal portion of the fixation system, at the ulnar side locking pin, or the locking screw was bent (groups 1, 2, 3); the ulnar side locking screw was broken (groups 3, 4); the locking screw became loose (group 4); and the ulnar side locking screw was uncoupled from the screw hole (group 5). All of the five volar plate fixation systems provided sufficient stability to permit 3000 repeated motions of the digits after surgery for AO type C3 distal radius fractures.
引用
收藏
页码:357 / 364
页数:8
相关论文
共 50 条
  • [1] Volar plating of AO C3 distal radius fractures: Biomechanical evaluation of locking screw and locking smooth peg configurations
    Martineau, P. A.
    Waitayawinyu, T.
    Malone, K. J.
    Hanel, D. P.
    Trumble, T. E.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (06): : 827 - 834
  • [2] Results of dorsal or volar plate fixation of AO type C3 distal radius fractures: A retrospective study
    Rein, Susanne
    Schikore, Hartmut
    Schneiders, Wolfgang
    Amlang, Michael
    Zwipp, Hans
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (07): : 954 - 961
  • [3] Dorsal and Volar 2.4-mm Locking Plate Fixation for AO Type C3 Dorsally Comminuted Distal Radius Fractures
    Chou, Ying-Chao
    Chen, Alvin Chao-Yu
    Chen, Chun-Ying
    Hsu, Yung-Heng
    Wu, Chi-Chuan
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (06): : 974 - 981
  • [4] A biomechanical comparison between two volar locking plate systems for distal radius fractures
    Chen, Li
    Dai, Qiang
    Wongworawat, Montri D.
    ORTHOPEDICS, 2006, 29 (10) : 927 - 929
  • [5] Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate - A biomechanical study in a cadaveric model
    Leung, F
    Zhu, L
    Ho, H
    Lu, WW
    Chow, SP
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2003, 28B (03): : 263 - 266
  • [6] Treatment of AO type C distal radius fractures with the use of volar locked plate
    Seyfettinoglu, Firat
    Ogur, Hasan Ulas
    Tuhanioglu, Umit
    Ciloglu, Osman
    Cicek, Hakan
    CUKUROVA MEDICAL JOURNAL, 2018, 43 (01): : 49 - 55
  • [7] Non-locking plate fixation for AO type C3 fracture of the distal radius
    Dohi, Y.
    Omokawa, S.
    Fujitani, R.
    Yajima, H.
    PROCEEDINGS OF THE 10TH CONGRESS OF THE INTERNATIONAL FEDERATION OF SOCIETIES FOR SURGERY OF THE HAND & 7TH CONGRESS OF THE INTERNATIONAL FEDERATION OF SOCIETIES FOR HAND THERAPY, 2007, : 179 - +
  • [8] Volar Locking Plate Compared With Combined Plating of AO Type C Distal Radius Fractures: A Randomized Controlled Study of 150 Cases
    Lundqvist, Eva
    Fischer, Per
    Wretenberg, Per
    Pettersson, Kurt
    Personat, Adolfo Lopez
    Sagerfors, Marcus
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2022, 47 (09): : 813 - 822
  • [9] The volar locking plate for extension fractures of the distal radius
    Pillukat, T.
    Fuhrmann, R.
    Windolf, J.
    van Schoonhoven, J.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2016, 28 (01): : 47 - 63
  • [10] Biomechanical Comparison of Volar Fixed-Angle Locking Plates for AO C3 Distal Radius Fractures: Titanium Versus Stainless Steel With Compression
    Marshall, Tyler
    Momaya, Amit
    Eberhardt, Alan
    Chaudhari, Nilesh
    Hunt, Thomas R., III
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (10): : 2032 - 2038