Stability of volar locking plate systems for AO type C3 fractures of the distal radius: biomechanical study in a cadaveric model

被引:25
|
作者
Kamei, Shuzo [1 ]
Osada, Denju [1 ]
Tamai, Kazuya [1 ]
Kato, Nakayuki [1 ]
Takai, Morimitsu [1 ]
Kameda, Masahiro [1 ]
Nohara, Yutaka [1 ]
机构
[1] Dokkyo Med Univ, Sch Med, Dept Orthopaed Surg, Mibu, Tochigi 3210293, Japan
关键词
FRAGMENT-SPECIFIC FIXATION; COMPRESSION PLATE; EXTERNAL FIXATION; DORSAL; SCREW;
D O I
10.1007/s00776-010-1466-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of the present study was to compare the relative stability of five volar locking plates (all of which are available for the treatment of intraarticular fractures of the distal radius) under loading conditions simulating the physiological forces that occur during early active mobilization. Five plating techniques were applied to surgically simulated AO type C3.2 distal radius fractures in formalin-fixed cadavers. The specimens were tested with a servohydraulic materials testing machine with 250 N of axial compression load for 3000 cycles. After cyclic loading, the specimens were loaded until they demonstrated failure in axial compression. The five fixation systems studied included a DRV locking plate (group 1), a Stellar plate (group 2), an Acu-Loc plate (group 3), AO Locking Distal Radius System 2.4 (group 4); and a Matrix SmartLock plate (group 5). None of the plate fixations tested failed during the cyclic loading. Group 2 had a higher elastic limit than groups 4 and 5. There were no significant differences among the five groups for the failure load. Failure occurred at the distal portion of the fixation system, at the ulnar side locking pin, or the locking screw was bent (groups 1, 2, 3); the ulnar side locking screw was broken (groups 3, 4); the locking screw became loose (group 4); and the ulnar side locking screw was uncoupled from the screw hole (group 5). All of the five volar plate fixation systems provided sufficient stability to permit 3000 repeated motions of the digits after surgery for AO type C3 distal radius fractures.
引用
收藏
页码:357 / 364
页数:8
相关论文
共 50 条
  • [41] Volar Fixed-Angle Plating of Distal Radius Fractures: Screws Versus Pegs-A Biomechanical Study in a Cadaveric Model
    Mehling, Isabella
    Klitscher, Daniela
    Mehling, Andreas P.
    Nowak, Tobias E.
    Sternstein, Werner
    Rommens, Pol M.
    Mueller, Lars P.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (07) : 395 - 401
  • [42] Residual wrist pain after volar locking plate fixation of distal radius fractures
    Kurimoto, Shigeru
    Tatebe, Masahiro
    Shinohara, Takaaki
    Arai, Tetsuya
    Hirata, Hitoshi
    ACTA ORTHOPAEDICA BELGICA, 2012, 78 (05): : 603 - 610
  • [43] Recovery of Wrist Function after Volar Locking Plate Fixation for Distal Radius Fractures
    Takeuchi, Naohide
    Hotokezaka, Shunsuke
    Okada, Takamitsu
    Yuge, Hidehiko
    Mae, Takao
    Iwamoto, Yukihide
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2016, 21 (02): : 199 - 206
  • [44] Volar Locking Plate Fixation of Distal Radius Fractures: Splint versus Immediate Mobilization
    Duprat, Andre
    Diaz, Juan Jose Hidalgo
    Vernet, Paul
    Gouzou, Stephanie
    Facca, Sybille
    Igeta, Yuka
    Liverneaux, Philippe
    JOURNAL OF WRIST SURGERY, 2018, 7 (03) : 237 - 242
  • [45] Volar locking plate fixation for distal radius fractures: Does age affect outcome?
    Ezzat, Ahmed
    Baliga, Santosh
    Carnegie, Carol
    Johnstone, Alan
    JOURNAL OF ORTHOPAEDICS, 2016, 13 (02) : 76 - 80
  • [46] Efficacy of volar locking plate fixation for unstable distal radius fractures in elderly patients
    Wang, Minghui
    Wang, Bin
    Wang, Xiuhui
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (02): : 1185 - 1191
  • [47] What are the ideal screw lengths in volar locking plate fixation for distal radius fractures?
    Kilian, M.
    Simkovic, P.
    Zamborsky, R.
    Skoda, A.
    Labas, P.
    BRATISLAVA MEDICAL JOURNAL-BRATISLAVSKE LEKARSKE LISTY, 2019, 120 (07): : 505 - 509
  • [48] Role of Pronator Quadratus Repair in Volar Locking Plate Treatment of Distal Radius Fractures
    Zhang, Dafang
    Meyer, Maximilian A.
    Earp, Brandon E.
    Blazar, Philip
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2022, 30 (15) : 696 - 702
  • [49] Volar-locking plate versus external fixator in the management of distal radius fractures: An isokinetic study
    Dundar, Abdulrahim
    Cankaya, Deniz
    Karakus, Dilek
    Tabak, Abdullah Yalcin
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2022, 28 (08): : 1156 - 1163
  • [50] Complications After Volar Locking Plate Fixation of Distal Radius Fractures: A Retrospective Study of 822 Patients
    Perregaard, Soren
    Jorgensen, Rasmus Wejnold
    Landgren, Marcus
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2024, 49 (08): : 745 - 750