Volar-locking plate versus external fixator in the management of distal radius fractures: An isokinetic study

被引:6
|
作者
Dundar, Abdulrahim [1 ]
Cankaya, Deniz [2 ]
Karakus, Dilek [3 ]
Tabak, Abdullah Yalcin [2 ]
机构
[1] Hitit Univ Training & Res Hosp, Dept Orthopaed & Traumatol, Corum, Turkey
[2] Gulhane Training & Res Hosp, Dept Orthopaed & Traumatol, Ankara, Turkey
[3] Ordu Univ Training & Res Hosp, Dept Phys Med & Rehabil, Ordu, Turkey
关键词
Distal radius fracture; external fixation; isokinetic evaluation; volar plate; DISPLACED INTRAARTICULAR FRACTURES; OPEN REDUCTION; GRIP STRENGTH; RELIABILITY; MOTION;
D O I
10.14744/tjtes.2021.72606
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: The aim of this study was to compare the clinical and isokinetic evaluation of distal radius fractures treated by volar locking plate (VLP) and external fixator. METHODS: The study included fifty patients with distal radius fracture type C1/C2/C3. Twenty-seven patients (12 men, 15 women; mean age 49.5 +/- 4.42) underwent open reduction and VLP fixation, and 23 patients (10 men, 13 women; 52.1 +/- 4.6) underwent closed reduction and external fixation. The follow-up period was at least 12 months and the mean following time was 13.5 +/- 1.02 (12-15) months. The functional parameters measured were range of motion (ROM) and grip strength. Radiographic parameters (radial inclination, palmar tilt, and radial height) and isokinetic evaluation were measured at the 6 months and at the final follow-up after surgery. The isokinetic test was done at the speed of 60 degrees/s. The non-fractured arm was tested first and all results were also expressed as a percentage of that on the normal side. Wrist scores according to the disability of the arm, shoulder, and hand (DASH) questionnaire were used. RESULTS: The DASH scores, grip strength, and palmar flexion were better in VLP group at the 6 months (p<0.05). However, there were no differences between two groups at the one year (p=0.79). Isokinetic evaluation of the VLP showed that peak pronation torque and total pronation work were better than external fixation at the 6 month (p<0.05). At the final of follow-up was seen no significant differences between two groups (p=0.11). CONCLUSION: We looked at external fixation and locked volar plates in a prospective study and we found an improved range of movement and isokinetic evaluation outcome at 6 months after locked plating, but there were no differences between two groups at the final of follow-up. Our study showed no evidence for the superiority of one treatment over the other at the final follow-up.
引用
收藏
页码:1156 / 1163
页数:8
相关论文
共 50 条
  • [1] Prospective Randomized Study Comparing the External Fixator and Volar Locking Plate in Intraarticular Distal Radius Fractures: Which Is Better?
    Sharma, Aryan
    Pathak, Subodh
    Sandhu, Harinder
    Bagtharia, Priyank
    Kumar, Naveen
    Bajwa, Rajdeep S.
    Pruthi, Vineet
    Chawla, Jasneet S.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (02)
  • [2] Volar locking plate versus external fixation in distal radius fractures: A meta-analysis
    Maccagnano, Giuseppe
    Noia, Giovanni
    Vicenti, Giovanni
    Baglioni, Marco
    Masciale, Maria Rosa
    Cassano, Giuseppe Danilo
    Vitiello, Raffaele
    Moretti, Biagio
    Pesce, Vito
    ORTHOPEDIC REVIEWS, 2021, 13 (01)
  • [3] The volar locking plate for extension fractures of the distal radius
    Pillukat, T.
    Fuhrmann, R.
    Windolf, J.
    van Schoonhoven, J.
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2016, 28 (01): : 47 - 63
  • [4] Volar locking plate fixation versus external fixation of distal radius fractures: a meta-analysis
    Gouk, Conor J. C.
    Bindra, Randip R.
    Tarrant, Drew J.
    Thomas, Michael J. E.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (09) : 954 - 960
  • [5] Comparison Between External Fixators and Fixed-Angle Volar-Locking Plates in the Treatment of Distal Radius Fractures
    Agustin Jorge-Mora, Alberto
    Cecilia-Lopez, David
    Rodriguez-Vega, Victor
    Suarez-Arias, Laura
    Andres-Esteban, Eva
    Porras-Moreno, Miguel Angel
    Resines-Erasun, Carlos
    JOURNAL OF HAND AND MICROSURGERY, 2012, 4 (02) : 50 - 54
  • [6] Treatment of unstable distal radius fractures with the volar locking plate
    Minegishi, Hanae
    Dohi, Osamu
    An, Soukan
    Sato, Hidetsugu
    UPSALA JOURNAL OF MEDICAL SCIENCES, 2011, 116 (04) : 280 - 284
  • [7] Volar locking plate fixation of unstable distal radius fractures
    Kilic, Ayhan
    Kabukcuoglu, Yavuz
    Ozkaya, Ufuk
    Gul, Murat
    Sokucu, Sami
    Ozdogan, Umit
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (04) : 303 - 308
  • [8] Breakage of volar locking plate system for distal radius fractures
    Kawanishi, Syohei
    Gato, Uasushi
    Nakai, Tsuyoshi
    ACTA ORTHOPAEDICA BELGICA, 2020, 86 (S 1): : 71 - 77
  • [9] Volar Locking Plate Fixation of Distal Radius Fractures: Splint versus Immediate Mobilization
    Duprat, Andre
    Diaz, Juan Jose Hidalgo
    Vernet, Paul
    Gouzou, Stephanie
    Facca, Sybille
    Igeta, Yuka
    Liverneaux, Philippe
    JOURNAL OF WRIST SURGERY, 2018, 7 (03) : 237 - 242
  • [10] Prospective study of distal radius fractures treated with a volar locking plate system
    Osada, Denju
    Kamei, Shuzo
    Masuzaki, Koichiro
    Takai, Morimitsu
    Kameda, Masahiro
    Tamai, Kazuya
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (05): : 691 - 700