Helical cone beam CT with an asymmetrical detector

被引:16
|
作者
Zamyatin, AA
Taguchi, K
Silver, MD
机构
[1] Bioimaging Res Inst, Lincolnshire, IL 60069 USA
[2] Toshiba Amer Med Syst, Tustin, CA 92780 USA
关键词
D O I
10.1118/1.2047784
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
If a multislice or other area detector is shifted to one side to cover a larger field of view, then the data are truncated on one side. We propose a method to restore the missing data in helical cone-beam acquisitions that uses measured data on the longer side of the asymmetric detector array. The method is based on the idea of complementary rays, which is well known in fan beam geometry; in this paper we extend this concept to the cone-beam case. Different cases of complementary data coverage and dependence on the helical pitch are considered. The proposed method is used in our prototype 16-row CT scanner with an asymmetric detector and a 700 mm field of view. For evaluation we used scanned body phantom data and computer-simulated data. To simulate asymmetric truncation, the full, symmetric datasets were truncated by dropping either 22.5% or 45% from one side of the detector. Reconstructed images from the prototype scanner with the asymmetrical detector show excellent image quality in the extended field of view. The proposed method allows flexible helical pitch selection and can be used with overscan, short-scan, and super-short-scan reconstructions. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:3117 / 3127
页数:11
相关论文
共 50 条
  • [41] Sparse sampling in helical cone-beam CT perfect reconstruction algorithms
    Bendory, Tamir
    Feuer, Arie
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (03) : 389 - 405
  • [42] Simulation studies for triple-source helical cone-beam CT
    Zhao, Jun
    Jin, Yannan
    Jiang, Ming
    Zhuang, Tiange
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [43] Use of beam shapers for cone-beam CT with off-centered flat detector
    Menser, Bernd
    Wiegert, Jens
    Wiesner, Steffen
    Bertram, Matthias
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [44] Comparison of radiation doses between cone beam CT and multi detector CT: TLD measurements
    Kim, Sangroh
    Yoshizumi, Terry T.
    Toncheva, Greta
    Yoo, Sua
    Yin, Fang-Fang
    RADIATION PROTECTION DOSIMETRY, 2008, 132 (03) : 339 - 345
  • [45] Helical cone-beam tomography
    Turbell, H
    Danielsson, PE
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2000, 11 (01) : 91 - 100
  • [46] Geometric Calibration of Cone-beam CT with a Flat-panel Detector
    Wu, Dufan
    Li, Liang
    Zhang, Li
    Xing, Yuxiang
    Chen, Zhiqiang
    Xiao, Yongshun
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2952 - 2955
  • [47] Flat-panel-detector cone-beam CT for orthopedics and surgery
    Baba, R
    Konno, Y
    Ueda, K
    RADIOLOGY, 2001, 221 : 544 - 544
  • [48] A new correction method for flat panel detector in Cone-Beam CT
    Zhang, Hua
    Huang, Kuidong
    Shi, Yikai
    CEIS 2011, 2011, 15
  • [49] Novel Detector Configurations in Cone-Beam CT Systems: A Simulation Study
    Karali, Evangelia
    Michail, Christos
    Fountos, George
    Kalyvas, Nektarios
    Valais, Ioannis
    CRYSTALS, 2024, 14 (05)
  • [50] Flat panel detector-based cone beam volume CT imaging
    Ning, R
    MEDICAL PHYSICS, 2003, 30 (06) : 1370 - 1370