Helical cone-beam tomography

被引:1
|
作者
Turbell, H [1 ]
Danielsson, PE [1 ]
机构
[1] Linkoping Univ, Dept Elect Engn, Image Proc Lab, SE-58183 Linkoping, Sweden
关键词
D O I
10.1002/(SICI)1098-1098(2000)11:1<91::AID-IMA10>3.0.CO;2-F
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recently, several computed tomography (CT) machines with multirow detectors have been introduced on the market. Although the projections are obtained from a cone beam rather than a fan beam, multislice reconstruction algorithms in contemporary machines are firmly rooted in two-dimensional (2D) reconstruction of planar objects. Short-scan algorithms are dominating and these are preferably classified according to how redundant data are handled, using parallel rebinning, complementary rebinning, or Parker weighting. In the long run, truly 3D cone-beam algorithms are likely to take over, however. It has proved to be quite a challenge to design an algorithm that is both practical and exact under the constraints set by helical source path geometry. All attempts in this direction are readily seen to be derivatives of Grangeat's algorithm. Alternative research efforts have been building on the nonexact algorithm by Feldkamp et al. (J Opt Soc Am 1: 612-619, 1984). These algorithms strive for simplicity using 1D filtering only. In this overview, we pay special attention to the PI method, which has the unique property that all object points are illuminated by the source during exactly 180 degrees, which generates complete and nonredundant data. Two new algorithms, PI-SLANT and P1-2D, are also presented with some experimental results. (C) 2000 John Wiley & Sons, Inc.
引用
收藏
页码:91 / 100
页数:10
相关论文
共 50 条
  • [1] Mart Algorithms for Circular and Helical Cone-Beam Tomography
    Jain, Nitin
    Raj, Anant
    Kalra, M. S.
    Munshi, Prabhat
    Ravindran, V. R.
    RESEARCH IN NONDESTRUCTIVE EVALUATION, 2011, 22 (03) : 147 - 168
  • [2] Fast hierarchical backprojection for helical cone-beam tomography
    Bresler, Y
    Brokish, J
    2003 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL 2, PROCEEDINGS, 2003, : 815 - 818
  • [3] Optoelectronic implementation of helical cone-beam computed tomography algorithms
    Madec, Morgan
    Fasquel, Jean-Baptiste
    Uhring, Wilfried
    Joffre, Pascal
    Herve, Yannick
    OPTICAL ENGINEERING, 2008, 47 (05)
  • [4] High-helical-pitch, cone-beam computed tomography
    Silver, MD
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04): : 847 - 855
  • [5] Metal Artifact Reduction in Helical Cone-beam Computed Tomography
    Tang, Jie
    Zhang, Li
    Chen, Zhiqiang
    Xing, Yuxiang
    Cheng, Jianping
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2878 - 2881
  • [6] A hierarchical algorithm for fast backprojection in helical cone-beam tomography
    Bresler, Y
    Brokish, J
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 AND 2, 2004, : 1420 - 1423
  • [7] Comparative evaluation of two analytical methods for helical cone-beam tomography
    Schoendube, Harald
    Stierstorfer, Karl
    Dennerlein, Frank
    Noo, Frederic
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4467 - +
  • [8] Practical geometric calibration for helical cone-beam industrial computed tomography
    Zhang, Feng
    Yan, Bin
    Li, Lei
    Xi, Xiaoqi
    Jiang, Hua
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2014, 22 (01) : 19 - 35
  • [9] A solution to the long-object problem in helical cone-beam tomography
    Defrise, M
    Noo, F
    Kudo, H
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (03): : 623 - 643
  • [10] Effect of noise in dual-energy helical cone-beam computed tomography
    Sidky, EY
    Zou, Y
    Pan, XC
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 396 - 402