Helical cone beam CT with an asymmetrical detector

被引:16
|
作者
Zamyatin, AA
Taguchi, K
Silver, MD
机构
[1] Bioimaging Res Inst, Lincolnshire, IL 60069 USA
[2] Toshiba Amer Med Syst, Tustin, CA 92780 USA
关键词
D O I
10.1118/1.2047784
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
If a multislice or other area detector is shifted to one side to cover a larger field of view, then the data are truncated on one side. We propose a method to restore the missing data in helical cone-beam acquisitions that uses measured data on the longer side of the asymmetric detector array. The method is based on the idea of complementary rays, which is well known in fan beam geometry; in this paper we extend this concept to the cone-beam case. Different cases of complementary data coverage and dependence on the helical pitch are considered. The proposed method is used in our prototype 16-row CT scanner with an asymmetric detector and a 700 mm field of view. For evaluation we used scanned body phantom data and computer-simulated data. To simulate asymmetric truncation, the full, symmetric datasets were truncated by dropping either 22.5% or 45% from one side of the detector. Reconstructed images from the prototype scanner with the asymmetrical detector show excellent image quality in the extended field of view. The proposed method allows flexible helical pitch selection and can be used with overscan, short-scan, and super-short-scan reconstructions. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:3117 / 3127
页数:11
相关论文
共 50 条
  • [21] Implementation and optimization of Katsevich algorithm for helical cone-beam CT
    Tang Qibo
    Wei Dongbo
    Li Dan
    Xu Haijun
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 3945 - 3948
  • [22] Accurate helical cone-beam CT reconstruction with redundant data
    Schoendube, Harald
    Stierstorfer, Karl
    Noo, Frederic
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (15): : 4625 - 4644
  • [23] Streak artifact reduction in helical cone beam CT with redundancy weighting
    Zamyatin, Alexander A.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4148 - 4149
  • [24] Artifact analysis and reconstruction improvement in helical cardiac cone beam CT
    Manzke, R
    Grass, M
    Hawkes, D
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (09) : 1150 - 1164
  • [25] Partial volume and aliasing artefacts in helical cone-beam CT
    Zou, Y
    Sidky, EY
    Pan, XC
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11): : 2365 - 2375
  • [26] Practical helical cone-beam algorithms for multislice volumetric CT
    Patch, SK
    Besson, GM
    RADIOLOGY, 1999, 213P : 451 - 451
  • [27] A Segmentation-Based Deformable Registration Algorithm for Cone Beam CT and Helical CT Images
    Li, X.
    Li, T.
    Yang, Y.
    Heron, D.
    Huq, M.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [28] Adaptive temporal resolution optimization in helical cardiac cone beam CT reconstruction
    Manzke, R
    Grass, M
    Nielsen, T
    Shechter, G
    Hawkes, D
    MEDICAL PHYSICS, 2003, 30 (12) : 3072 - 3080
  • [29] Half-cover scanning and reconstructing for helical cone-beam CT
    Zou, Xiao-Bing
    Zeng, Li
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2010, 18 (02): : 434 - 442
  • [30] BPF-Type Reconstruction for Dual Helical Cone-Beam CT
    Zeng, Li
    Zou, Xiaobing
    CURRENT MEDICAL IMAGING, 2011, 7 (02) : 125 - 135