A comparison of visual outcome and rotational stability of two types of toric implantable collamer lenses (TICL): V4 versus V4c

被引:40
|
作者
Hyun, Joo [1 ,2 ]
Lim, Dong Hui [1 ,3 ]
Eo, Doo Ri [1 ]
Hwang, Sungsoon [1 ]
Chung, Eui-Sang [4 ]
Chung, Tae-Young [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Dept Ophthalmol, Sch Med, Seoul, South Korea
[2] Saevit Eye Hosp, Dept Ophthalmol, Goyang, South Korea
[3] Catholic Univ Korea, Dept Prevent Med, Coll Med, Seoul, South Korea
[4] Rhees Eye Hosp, Daejeon, South Korea
来源
PLOS ONE | 2017年 / 12卷 / 08期
关键词
PHAKIC INTRAOCULAR-LENS; HIGH MYOPIC ASTIGMATISM; CENTRAL HOLE; CLINICAL-OUTCOMES; PUPILLARY BLOCK; AXIS ALIGNMENT; GLAUCOMA; BIOMETRY; MODERATE; EYES;
D O I
10.1371/journal.pone.0183335
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To compare the efficacy and rotational stability after implantation of two types of toric implantable collamer lenses (Toric ICL (TM)(TICL);V4 and V4c, STAAR Surgical Co.) Study design Retrospective case series. Methods This retrospective study evaluated total 48 eyes of 48 patients who underwent the implantation with V4 and V4c TICL with a central hole; A twenty-four eyes of 24 patients with V4 TICL and 24 eyes of 24 patients with V4c TICL with a central hole. Visual acuity, manifest refraction, and intraocular pressure were evaluated before and after surgery. Rotational stability (disparity between the intended axis and achieved axis) was assessed in both groups using digital anterior segment photographs, and vector analysis was also performed. Results Uncorrected visual acuity improved in both groups without significant difference (P = .111). There were no statistical differences between two groups in postoperative SE and cylindrical errors (P = .067 and .384, respectively). The mean value of rotation was 4.17 +/- 3.31 degrees and 3.39 +/- 2.36 degrees in the V4 and V4c TICL groups, respectively without significant difference (P = .364). Vector analysis of astigmatic correction showed no significant diffrence between two groups. Conclusion V4 and V4c TICL have similar efficacy with regard to visual acuity and refractive outcomes and rotational stability.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] A four-year observation of corneal densitometry after implantable collamer lens V4c implantation
    Zhao, Jing
    Yang, Wen
    Zhao, Jiao
    Shen, Yang
    Sun, Ling
    Han, Tian
    Wang, Xiaoying
    Yao, Peijun
    Zhou, Xingtao
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (07)
  • [32] Anterior segment optical coherence tomography angle and vault analysis after toric and non-toric implantable collamer lens V4c implantation in patients with high myopia
    Garcia-De la Rosa, Guillermo
    Olivo-Payne, Andrew
    Carlos Serna-Ojeda, Juan
    Sandra Salazar-Ramos, Maria
    Lichtinger, Alejandro
    Gomez-Bastar, Arturo
    Ramirez-Miranda, Arturo
    Navas, Alejandro
    Graue-Hernandez, Enrique O.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (04) : 544 - 548
  • [33] Visual outcomes after small incision lenticule extraction and implantable collamer lens V4c for moderate myopia: 1-year results
    Aruma Aruma
    Meiyan Li
    Joanne Choi
    Huamao Miao
    Ruoyan Wei
    Danjuan Yang
    Peijun Yao
    Ling Sun
    Xiaoying Wang
    Xingtao Zhou
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2021, 259 : 2431 - 2440
  • [34] Visual outcomes after small incision lenticule extraction and implantable collamer lens V4c for moderate myopia: 1-year results
    Aruma, Aruma
    Li, Meiyan
    Choi, Joanne
    Miao, Huamao
    Wei, Ruoyan
    Yang, Danjuan
    Yao, Peijun
    Sun, Ling
    Wang, Xiaoying
    Zhou, Xingtao
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (08) : 2431 - 2440
  • [35] The Long-term Visual Quality and Rotational Stability After ICL/TICL V4c Implantation in Individuals With High Myopia Older Than 40 Years
    Ye, Yuhao
    Xu, Yijia
    Zhang, Zhe
    Niu, Lingling
    Shi, Wanru
    Wang, Xiaoying
    Zhou, Xingtao
    Zhao, Jing
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (06) : e381 - e391
  • [36] Changes in anterior lens density after Implantable Collamer Lens V4c implantation: a 4-year prospective observational study
    Yang, Wen
    Zhao, Jing
    Zhao, Jiao
    Shen, Yang
    Niu, Lingling
    Ruma, A.
    Wang, Xiaoying
    Zhou, Xingtao
    ACTA OPHTHALMOLOGICA, 2021, 99 (03) : 326 - 333
  • [37] Long-Term Evaluation of Central and Peripheral Lens Densities Post Implantation of Implantable Collamer Lens V4c
    Lin, I. -Chun
    Jiang, Yinjie
    Cheng, Mingrui
    Li, Boliang
    Lei, Yadi
    Xu, Guanghan
    Li, Mingwei
    Mao, Zhiwei
    Rui, Ning
    Chen, Xun
    Wang, Xiaoying
    CLINICAL OPHTHALMOLOGY, 2025, 19 : 733 - 745
  • [38] Long-term observation of V4c implantable collamer lenses implantation for moderate to extreme high myopia correction: five years follow-up
    Wan, Qi
    He, Peiyuan
    Wei, Ran
    Ma, Ke
    Yin, Hongbo
    Tang, Jing
    Deng, Ying-ping
    EYE, 2024, 38 (10) : 1933 - 1940
  • [39] Refractive outcomes after V4c Toric collamer lens implantation over 1y of follow-up
    Carreras-Diaz, Humberto
    de Abajo, Josefina Renones
    Carreras-Diaz, Mariaia del Rosario
    Lorente-Velazquez, Amalia
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2024, 17 (07) : 1322 - 1330
  • [40] The Relationship between Anterior Chamber Angle and Intraocular Pressure Early after V4c Implantable Collamer Lens Implantation
    Hu, Zongli
    Chen, Chunlin
    Sun, Min
    Yuan, Rongdi
    Ye, Jian
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020