A comparison of visual outcome and rotational stability of two types of toric implantable collamer lenses (TICL): V4 versus V4c

被引:40
|
作者
Hyun, Joo [1 ,2 ]
Lim, Dong Hui [1 ,3 ]
Eo, Doo Ri [1 ]
Hwang, Sungsoon [1 ]
Chung, Eui-Sang [4 ]
Chung, Tae-Young [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Dept Ophthalmol, Sch Med, Seoul, South Korea
[2] Saevit Eye Hosp, Dept Ophthalmol, Goyang, South Korea
[3] Catholic Univ Korea, Dept Prevent Med, Coll Med, Seoul, South Korea
[4] Rhees Eye Hosp, Daejeon, South Korea
来源
PLOS ONE | 2017年 / 12卷 / 08期
关键词
PHAKIC INTRAOCULAR-LENS; HIGH MYOPIC ASTIGMATISM; CENTRAL HOLE; CLINICAL-OUTCOMES; PUPILLARY BLOCK; AXIS ALIGNMENT; GLAUCOMA; BIOMETRY; MODERATE; EYES;
D O I
10.1371/journal.pone.0183335
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To compare the efficacy and rotational stability after implantation of two types of toric implantable collamer lenses (Toric ICL (TM)(TICL);V4 and V4c, STAAR Surgical Co.) Study design Retrospective case series. Methods This retrospective study evaluated total 48 eyes of 48 patients who underwent the implantation with V4 and V4c TICL with a central hole; A twenty-four eyes of 24 patients with V4 TICL and 24 eyes of 24 patients with V4c TICL with a central hole. Visual acuity, manifest refraction, and intraocular pressure were evaluated before and after surgery. Rotational stability (disparity between the intended axis and achieved axis) was assessed in both groups using digital anterior segment photographs, and vector analysis was also performed. Results Uncorrected visual acuity improved in both groups without significant difference (P = .111). There were no statistical differences between two groups in postoperative SE and cylindrical errors (P = .067 and .384, respectively). The mean value of rotation was 4.17 +/- 3.31 degrees and 3.39 +/- 2.36 degrees in the V4 and V4c TICL groups, respectively without significant difference (P = .364). Vector analysis of astigmatic correction showed no significant diffrence between two groups. Conclusion V4 and V4c TICL have similar efficacy with regard to visual acuity and refractive outcomes and rotational stability.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c)
    Xun Chen
    Huamao Miao
    Rajeev Krishnan Naidu
    Xiaoying Wang
    Xingtao Zhou
    BMC Ophthalmology, 16
  • [22] Effects of tilt and decentration of Visian Implantable Collamer Lens (ICL V4c) on visual quality: an observational study
    Lingling Niu
    Zhe Zhang
    Huamao Miao
    Jing Zhao
    Meiyan Li
    Ji C. He
    Peijun Yao
    Xingtao Zhou
    BMC Ophthalmology, 22
  • [23] Effects of tilt and decentration of Visian Implantable Collamer Lens (ICL V4c) on visual quality: an observational study
    Niu, Lingling
    Zhang, Zhe
    Miao, Huamao
    Zhao, Jing
    Li, Meiyan
    He, Ji C.
    Yao, Peijun
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [24] Effects of Decentration of Implantable Collamer Lens V4c on Visual Quality With the OPD-Scan III Aberrometer
    Chen, Xun
    Lin, I-chun
    Miao, Huamao
    Cheng, Mingrui
    Li, Boliang
    Jiang, Yinjie
    Lei, Yadi
    Wang, Xiaoying
    Zhou, Xingtao
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 259 : 88 - 95
  • [25] Comparison of long-term visual quality after keratorefractive lenticule extraction and implantable collamer lens V4c for high myopia
    Zhan, Biyun
    Huang, Yangyi
    Chen, Xun
    Aruma, Aruma
    Cheng, Mingrui
    Wang, Xiaoying
    Zhou, Xingtao
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (11): : 1157 - 1164
  • [26] Early outcomes of anterior segment parameters after implantable collamer lens V4c implantation
    Lin, Qinghong
    Yang, Dong
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [27] Early outcomes of anterior segment parameters after implantable collamer lens V4c implantation
    Qinghong Lin
    Dong Yang
    Xingtao Zhou
    BMC Ophthalmology, 22
  • [28] Comparing the Early Changes in Classified Higher-Order Aberrations Before and After Non-Toric and Toric Implantable Collamer Lens V4c Implantation
    Lin, I-Chun
    Chen, Xun
    Cheng, Mingrui
    Miao, Huamao
    Li, Boliang
    Jiang, Yinjie
    Lei, Yadi
    Xu, Yilin
    Wang, Xiaoying
    Zhou, Xingtao
    CURRENT EYE RESEARCH, 2024, 49 (11) : 1154 - 1160
  • [29] Endothelial cell loss post-implantable collamer lens V4c: meta-analysis
    Kisiel, Filip Blazej
    Gurumurthy, Gerard Jonathan
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (04): : 420 - 423
  • [30] Analysis of Inter-Eye Vault Differences After Implantable Collamer Lens (V4c) Implantation
    Tan, Xin
    Liu, Wenjie
    Chang, Ying
    Wu, Wanmin
    Yang, Lichun
    Liu, Jiewei
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2023, 16 : 2451 - 2459