A comparison of visual outcome and rotational stability of two types of toric implantable collamer lenses (TICL): V4 versus V4c

被引:40
|
作者
Hyun, Joo [1 ,2 ]
Lim, Dong Hui [1 ,3 ]
Eo, Doo Ri [1 ]
Hwang, Sungsoon [1 ]
Chung, Eui-Sang [4 ]
Chung, Tae-Young [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Dept Ophthalmol, Sch Med, Seoul, South Korea
[2] Saevit Eye Hosp, Dept Ophthalmol, Goyang, South Korea
[3] Catholic Univ Korea, Dept Prevent Med, Coll Med, Seoul, South Korea
[4] Rhees Eye Hosp, Daejeon, South Korea
来源
PLOS ONE | 2017年 / 12卷 / 08期
关键词
PHAKIC INTRAOCULAR-LENS; HIGH MYOPIC ASTIGMATISM; CENTRAL HOLE; CLINICAL-OUTCOMES; PUPILLARY BLOCK; AXIS ALIGNMENT; GLAUCOMA; BIOMETRY; MODERATE; EYES;
D O I
10.1371/journal.pone.0183335
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To compare the efficacy and rotational stability after implantation of two types of toric implantable collamer lenses (Toric ICL (TM)(TICL);V4 and V4c, STAAR Surgical Co.) Study design Retrospective case series. Methods This retrospective study evaluated total 48 eyes of 48 patients who underwent the implantation with V4 and V4c TICL with a central hole; A twenty-four eyes of 24 patients with V4 TICL and 24 eyes of 24 patients with V4c TICL with a central hole. Visual acuity, manifest refraction, and intraocular pressure were evaluated before and after surgery. Rotational stability (disparity between the intended axis and achieved axis) was assessed in both groups using digital anterior segment photographs, and vector analysis was also performed. Results Uncorrected visual acuity improved in both groups without significant difference (P = .111). There were no statistical differences between two groups in postoperative SE and cylindrical errors (P = .067 and .384, respectively). The mean value of rotation was 4.17 +/- 3.31 degrees and 3.39 +/- 2.36 degrees in the V4 and V4c TICL groups, respectively without significant difference (P = .364). Vector analysis of astigmatic correction showed no significant diffrence between two groups. Conclusion V4 and V4c TICL have similar efficacy with regard to visual acuity and refractive outcomes and rotational stability.
引用
收藏
页数:13
相关论文
共 50 条
  • [11] Buffering zone of implantable Collamer lens sizing in V4c
    Seung Wan Nam
    Dong Hui Lim
    Joo Hyun
    Eui-Sang Chung
    Tae-Young Chung
    BMC Ophthalmology, 17
  • [12] Comparison of Visual and Refractive Outcome between Two Methods of Corneal Marking for Toric Implantable Collamer Lenses (TICL) in Phakic Eyes
    Feldhaus, Lukas
    Mayer, Wolfgang J.
    Dirisamer, Martin
    Kassumeh, Stefan
    Shajari, Mehdi
    Priglinger, Siegfried G.
    Luft, Nikolaus
    CURRENT EYE RESEARCH, 2023, 48 (04) : 357 - 364
  • [13] Safety and efficacy of toric implantable collamer lens V4c model - A retrospective South Indian study
    Chaitanya, S. Ravi
    Anitha, Venugopal
    Ravindran, Meenakshi
    Ghorpade, Aditya
    Rengappa, Ramakrishnan
    Uduman, Mahammed Sithiq
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (12) : 3006 - 3011
  • [14] Prospective Randomized Multicenter Comparison of the Clinical Outcomes of V4c and V5 Implantable Collamer Lenses: A Contralateral Eye Study
    Kojima, Takashi
    Kitazawa, Yoshihiro
    Nakamura, Tomoaki
    Takahashi, Masahide
    Kamiya, Kazutaka
    Ichikawa, Kazuo
    Igarashi, Akihito
    Shimizu, Kimiya
    JOURNAL OF OPHTHALMOLOGY, 2018, 2018
  • [15] Comparison of postoperative optical quality according to the degree of decentering of V4c implantable collamer lens
    Park, Min Ji
    Jeon, Hye Min
    Lee, Kyoung Heon
    Han, Sang Youp
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (04) : 619 - 623
  • [16] Comparison of postoperative optical quality according to the degree of decentering of V4c implantable collamer lens
    Min Ji Park
    Hye Min Jeon
    Kyoung Heon Lee
    Sang Youp Han
    International Journal of Ophthalmology, 2017, (04) : 619 - 623
  • [17] Comparison of objective and subjective visual quality early after implantable collamer lens V4c (ICL V4c) and small incision lenticule extraction (SMILE) for high myopia correction
    Wei, Ruoyan
    Li, Meiyan
    Zhang, Huihui
    Aruma, Aruma
    Miao, Huamao
    Wang, Xiaoying
    Zhou, Jin
    Zhou, Xingtao
    ACTA OPHTHALMOLOGICA, 2020, 98 (08) : E943 - E950
  • [18] Visual outcomes and corneal biomechanics after V4c implantable collamer lens implantation in subclinical keratoconus
    Li, Kangjun
    Wang, Zheng
    Zhang, Dexiu
    Wang, Shanshan
    Song, Xiaocui
    Li, Yaxin
    Wang, Ming X.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (10): : 1339 - 1345
  • [19] Dynamic Vaulting Changes in V4c versus V4 Posterior Chamber Phakic Lenses Under Differing Lighting Conditions
    Lee, Hun
    Kang, Sung Yong
    Seo, Kyoung Yul
    Chung, Byunghoon
    Choi, Jin Young
    Kim, Kyu Seo
    Kim, Tae-Im
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (06) : 1199 - 1204
  • [20] Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole (ICL V4 and ICL V4c)
    Chen, Xun
    Miao, Huamao
    Naidu, Rajeev Krishnan
    Wang, Xiaoying
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2016, 16