Refractive outcomes after V4c Toric collamer lens implantation over 1y of follow-up

被引:0
|
作者
Carreras-Diaz, Humberto [1 ]
de Abajo, Josefina Renones [1 ]
Carreras-Diaz, Mariaia del Rosario [2 ]
Lorente-Velazquez, Amalia [3 ]
机构
[1] Vithas Eurocanarias, Las Palmas Gran Canaria 35004, Spain
[2] Univ Hosp Girona Doctor Josep Trueta, Girona 17007, Spain
[3] Univ Complutense Madrid, Fac Opt & Optometry, Dept Optometry & Vis, Madrid 28040, Spain
关键词
V4c Toric collamer lens; corneal astigmatism; surgically induced astigmatism; corneal coupling; PHAKIC INTRAOCULAR-LENS; ASTIGMATISM ANALYSIS; POSTERIOR; DYNAMICS; ANTERIOR; MYOPIA; VAULT;
D O I
10.18240/ijo.2024.07.18
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port (V4c T-ICL) implantation over 1y of follow-up. METHODS: A retrospective study was performed including 50 eyes of 50 patients that underwent V4c T-ICL implantation. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, refractive and corneal astigmatism changes and corneal coupling correction were evaluated preoperatively, 1 and 12mo postoperatively. Vector analysis was used for astigmatism changes. Coefficient of adjustment (CAdj) was calculated for corneal coupling analysis. RESULTS: The mean UDVA achieved was 0.03 logMAR at 1mo and remained unchanged throughout the whole follow-up (P=0.193). P =0.193). At the last visit, 84% of the eyes achieved a CDVA of 0.00 logMAR or better. Regarding spherical equivalent refraction (SEQ), 96% of eyes were ranges of +/- 1.00 D and 84% of them within +/- 0.50 D. Also, 94% of eyes had a remaining refractive cylinder within +/- 1.00 D and 78% of them within +/- 0.50 D. Both, SEQ and refractive cylinder, remain stable over the postoperative follow-up (P=1.000 P =1.000 and P =0.660, respectively). In terms of surgically induced astigmatism (SIA), no statistically significant differences were found over the follow-up (P=0.102) P =0.102) and under correction was found with a correction index lower than the unit at each visit. A keratometric astigmatism induced of 0.59 +/- 0.53 (vector mean: 0.26x73 degrees) D was reached at the last visit. No significant changes in terms of corneal astigmatism orientation were reported over post-surgery visits (P=0.129 P =0.129 and P =0.097 at 1 and 12mo respectively). No clinical significance was found for CAdj on with-the-rule astigmatism. No postoperative complications resulting from the surgery were found. CONCLUSION: Refractive outcomes suggest that the V4c T-ICL implantation for correction of myopic astigmatism was satisfactory in terms of effectiveness, safety, and stability during 1y of follow-up. Corneal astigmatism induced by the incision around 0.5 D is achieved according to the remaining refractive cylinder found at one-year post-surgery. Corneal coupling analysis results in no unexpected spherical change.
引用
收藏
页码:1322 / 1330
页数:9
相关论文
共 50 条
  • [1] Comparison of visual outcomes after non-toric and toric implantable collamer lens V4c for myopia and astigmatism
    Wei, Ruoyan
    Li, Meiyan
    Niu, Lingling
    Aruma, Aruma
    Miao, Huamao
    Shen, Yang
    Yao, Peijun
    Wang, Xiaoying
    Zhang, Huihui
    Zhou, Xingtao
    ACTA OPHTHALMOLOGICA, 2021, 99 (05) : 511 - 518
  • [2] Efficacy and Safety of Implantable Collamer Lens V4c Implantation in 1,834 Myopic Eyes for 1 Year of Follow-up
    Du, Jingxiao
    Zhou, Wenkai
    Zhao, Ting
    Qian, Tianwei
    Lu, Yi
    Li, Haiyan
    Zhang, Zhihua
    Lian, Jingcai
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (10) : 694 - 704
  • [3] Early outcomes of anterior segment parameters after implantable collamer lens V4c implantation
    Lin, Qinghong
    Yang, Dong
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [4] Early outcomes of anterior segment parameters after implantable collamer lens V4c implantation
    Qinghong Lin
    Dong Yang
    Xingtao Zhou
    BMC Ophthalmology, 22
  • [5] Polar value analysis of astigmatic change and rotational stability after implantation of V4c toric implantable collamer lens
    Nie, Danyao
    Yan, Pisong
    Yan, Zonghui
    Zhang, Jing
    He, Wenling
    Li, Ming
    Sun, Liangnan
    Huang, Mingquan
    Liu, Xinhua
    Lin, Haotian
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (02)
  • [6] Visual outcomes and corneal biomechanics after V4c implantable collamer lens implantation in subclinical keratoconus
    Li, Kangjun
    Wang, Zheng
    Zhang, Dexiu
    Wang, Shanshan
    Song, Xiaocui
    Li, Yaxin
    Wang, Ming X.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (10): : 1339 - 1345
  • [7] Refractive outcomes and optical quality after implantation of posterior chamber phakic implantable collamer lens with a central hole (ICL V4c)
    Huamao Miao
    Xun Chen
    Mi Tian
    Yingjun Chen
    Xiaoying Wang
    Xingtao Zhou
    BMC Ophthalmology, 18
  • [8] Refractive outcomes and optical quality after implantation of posterior chamber phakic implantable collamer lens with a central hole (ICL V4c)
    Miao, Huamao
    Chen, Xun
    Tian, Mi
    Chen, Yingjun
    Wang, Xiaoying
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2018, 18
  • [9] Long-term follow-up for monovision surgery by Implantable Collamer Lens V4c implantation for myopia correction in early presbyopia
    Ye, Yuhao
    Zhao, Jing
    Zhang, Zhe
    Niu, Lingling
    Shi, Wanru
    Wang, Xiaoying
    Zhou, Xingtao
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (08) : 2763 - 2771
  • [10] Long-term follow-up for monovision surgery by Implantable Collamer Lens V4c implantation for myopia correction in early presbyopia
    Yuhao Ye
    Jing Zhao
    Zhe Zhang
    Lingling Niu
    Wanru Shi
    Xiaoying Wang
    Xingtao Zhou
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2022, 260 : 2763 - 2771