Refractive outcomes after V4c Toric collamer lens implantation over 1y of follow-up

被引:0
|
作者
Carreras-Diaz, Humberto [1 ]
de Abajo, Josefina Renones [1 ]
Carreras-Diaz, Mariaia del Rosario [2 ]
Lorente-Velazquez, Amalia [3 ]
机构
[1] Vithas Eurocanarias, Las Palmas Gran Canaria 35004, Spain
[2] Univ Hosp Girona Doctor Josep Trueta, Girona 17007, Spain
[3] Univ Complutense Madrid, Fac Opt & Optometry, Dept Optometry & Vis, Madrid 28040, Spain
关键词
V4c Toric collamer lens; corneal astigmatism; surgically induced astigmatism; corneal coupling; PHAKIC INTRAOCULAR-LENS; ASTIGMATISM ANALYSIS; POSTERIOR; DYNAMICS; ANTERIOR; MYOPIA; VAULT;
D O I
10.18240/ijo.2024.07.18
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port (V4c T-ICL) implantation over 1y of follow-up. METHODS: A retrospective study was performed including 50 eyes of 50 patients that underwent V4c T-ICL implantation. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, refractive and corneal astigmatism changes and corneal coupling correction were evaluated preoperatively, 1 and 12mo postoperatively. Vector analysis was used for astigmatism changes. Coefficient of adjustment (CAdj) was calculated for corneal coupling analysis. RESULTS: The mean UDVA achieved was 0.03 logMAR at 1mo and remained unchanged throughout the whole follow-up (P=0.193). P =0.193). At the last visit, 84% of the eyes achieved a CDVA of 0.00 logMAR or better. Regarding spherical equivalent refraction (SEQ), 96% of eyes were ranges of +/- 1.00 D and 84% of them within +/- 0.50 D. Also, 94% of eyes had a remaining refractive cylinder within +/- 1.00 D and 78% of them within +/- 0.50 D. Both, SEQ and refractive cylinder, remain stable over the postoperative follow-up (P=1.000 P =1.000 and P =0.660, respectively). In terms of surgically induced astigmatism (SIA), no statistically significant differences were found over the follow-up (P=0.102) P =0.102) and under correction was found with a correction index lower than the unit at each visit. A keratometric astigmatism induced of 0.59 +/- 0.53 (vector mean: 0.26x73 degrees) D was reached at the last visit. No significant changes in terms of corneal astigmatism orientation were reported over post-surgery visits (P=0.129 P =0.129 and P =0.097 at 1 and 12mo respectively). No clinical significance was found for CAdj on with-the-rule astigmatism. No postoperative complications resulting from the surgery were found. CONCLUSION: Refractive outcomes suggest that the V4c T-ICL implantation for correction of myopic astigmatism was satisfactory in terms of effectiveness, safety, and stability during 1y of follow-up. Corneal astigmatism induced by the incision around 0.5 D is achieved according to the remaining refractive cylinder found at one-year post-surgery. Corneal coupling analysis results in no unexpected spherical change.
引用
收藏
页码:1322 / 1330
页数:9
相关论文
共 50 条
  • [31] Visual and Refractive Outcomes After Implantation of a New Intraocular Lens: 6 Month Follow-Up
    Migliorati, G.
    Salvetat, M. L.
    Zeppieri, M. W.
    Brusini, P.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [32] The Relationship between Anterior Chamber Angle and Intraocular Pressure Early after V4c Implantable Collamer Lens Implantation
    Hu, Zongli
    Chen, Chunlin
    Sun, Min
    Yuan, Rongdi
    Ye, Jian
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [33] Changes of dysfunctional lens index before and after implantable collamer lens V4c implantation in patients with moderate-to-high myopia
    Weifang Cao
    Suhua Zhang
    Qian Liu
    Jing Zhou
    Xiaoyong Yuan
    International Ophthalmology, 2023, 43 : 4111 - 4120
  • [34] Long-Term Evaluation of Central and Peripheral Lens Densities Post Implantation of Implantable Collamer Lens V4c
    Lin, I. -Chun
    Jiang, Yinjie
    Cheng, Mingrui
    Li, Boliang
    Lei, Yadi
    Xu, Guanghan
    Li, Mingwei
    Mao, Zhiwei
    Rui, Ning
    Chen, Xun
    Wang, Xiaoying
    CLINICAL OPHTHALMOLOGY, 2025, 19 : 733 - 745
  • [35] Long-term observation of V4c implantable collamer lenses implantation for moderate to extreme high myopia correction: five years follow-up
    Wan, Qi
    He, Peiyuan
    Wei, Ran
    Ma, Ke
    Yin, Hongbo
    Tang, Jing
    Deng, Ying-ping
    EYE, 2024, 38 (10) : 1933 - 1940
  • [36] Impacts of Implantable Collamer Lens V4c Placement on Angle Measurements Made by Optical Coherence Tomography: Two-Year Follow-up Reply
    Ignacio Fernandez-Vigo, Jose
    Macarro-Merino, Ana
    Fernandez-Vigo, Cristina
    De-Pablo-Gomez-De-Liano, Lucia
    Fernandez-Perez, Cristina
    Garcia-Feijoo, Julian
    Angel Fernandez-Vigo, Jose
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2018, 186 : 172 - 173
  • [37] Visual outcomes after small incision lenticule extraction and implantable collamer lens V4c for moderate myopia: 1-year results
    Aruma Aruma
    Meiyan Li
    Joanne Choi
    Huamao Miao
    Ruoyan Wei
    Danjuan Yang
    Peijun Yao
    Ling Sun
    Xiaoying Wang
    Xingtao Zhou
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2021, 259 : 2431 - 2440
  • [38] Visual outcomes after small incision lenticule extraction and implantable collamer lens V4c for moderate myopia: 1-year results
    Aruma, Aruma
    Li, Meiyan
    Choi, Joanne
    Miao, Huamao
    Wei, Ruoyan
    Yang, Danjuan
    Yao, Peijun
    Sun, Ling
    Wang, Xiaoying
    Zhou, Xingtao
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (08) : 2431 - 2440
  • [39] Visual Outcomes Early after Implantable Collamer Lens V4c Implantation in Different Preoperative Spectacle Correction: Full Correction vs. Under Correction
    Zhu, Jiru
    Zhou, Tianan
    Yang, Qianjie
    Tong, Jianping
    Shen, Ye
    CURRENT EYE RESEARCH, 2023, 48 (06) : 576 - 583
  • [40] Corneal Aberrometic changes after ICL V4C intraocular lens implantation
    Garcia Padilla, Luis Antonio
    Vera-Duarte, Guillermo Raul
    Ramirez-Miranda, Arturo J.
    Kahuam-Lopez, Nicolas
    Haro-Morlett, Luis
    Graue-Hernandez, Enrique O.
    Navas, Alejandro
    Muller Morales, Adolfo
    Rubio, Gustavo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)