A comparison of visual outcome and rotational stability of two types of toric implantable collamer lenses (TICL): V4 versus V4c

被引:40
|
作者
Hyun, Joo [1 ,2 ]
Lim, Dong Hui [1 ,3 ]
Eo, Doo Ri [1 ]
Hwang, Sungsoon [1 ]
Chung, Eui-Sang [4 ]
Chung, Tae-Young [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Dept Ophthalmol, Sch Med, Seoul, South Korea
[2] Saevit Eye Hosp, Dept Ophthalmol, Goyang, South Korea
[3] Catholic Univ Korea, Dept Prevent Med, Coll Med, Seoul, South Korea
[4] Rhees Eye Hosp, Daejeon, South Korea
来源
PLOS ONE | 2017年 / 12卷 / 08期
关键词
PHAKIC INTRAOCULAR-LENS; HIGH MYOPIC ASTIGMATISM; CENTRAL HOLE; CLINICAL-OUTCOMES; PUPILLARY BLOCK; AXIS ALIGNMENT; GLAUCOMA; BIOMETRY; MODERATE; EYES;
D O I
10.1371/journal.pone.0183335
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To compare the efficacy and rotational stability after implantation of two types of toric implantable collamer lenses (Toric ICL (TM)(TICL);V4 and V4c, STAAR Surgical Co.) Study design Retrospective case series. Methods This retrospective study evaluated total 48 eyes of 48 patients who underwent the implantation with V4 and V4c TICL with a central hole; A twenty-four eyes of 24 patients with V4 TICL and 24 eyes of 24 patients with V4c TICL with a central hole. Visual acuity, manifest refraction, and intraocular pressure were evaluated before and after surgery. Rotational stability (disparity between the intended axis and achieved axis) was assessed in both groups using digital anterior segment photographs, and vector analysis was also performed. Results Uncorrected visual acuity improved in both groups without significant difference (P = .111). There were no statistical differences between two groups in postoperative SE and cylindrical errors (P = .067 and .384, respectively). The mean value of rotation was 4.17 +/- 3.31 degrees and 3.39 +/- 2.36 degrees in the V4 and V4c TICL groups, respectively without significant difference (P = .364). Vector analysis of astigmatic correction showed no significant diffrence between two groups. Conclusion V4 and V4c TICL have similar efficacy with regard to visual acuity and refractive outcomes and rotational stability.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Rotational Stability and Outcomes of V4c Toric Implantable Collamer Lenses Placed at Different Lens Orientations
    Yang, Yukun
    Zhu, Fengjiao
    Ma, Yiping
    Li, Jing
    Li, Xiaoxi
    Yao, Xiaoming
    JOURNAL OF REFRACTIVE SURGERY, 2025, 41 (01) : e29 - e38
  • [2] Rotational Stability and Visual Outcomes of V4c Toric Phakic Intraocular Lenses
    Lee, Hun
    Kang, David Sung Yong
    Choi, Jin Young
    Ha, Byoung Jin
    Kim, Eung Kweon
    Seo, Kyoung Yul
    Kim, Tae-im
    JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (07) : 489 - +
  • [3] The effect of mydriasis on moderate-to-high myopic eyes with implantable collamer lenses V4 and V4c
    Zhu, Yi
    Zhang, Jing
    Zhu, Haobin
    Chen, Jili
    Zhou, Jibo
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (03) : 462 - 468
  • [4] Comparison of visual outcomes after non-toric and toric implantable collamer lens V4c for myopia and astigmatism
    Wei, Ruoyan
    Li, Meiyan
    Niu, Lingling
    Aruma, Aruma
    Miao, Huamao
    Shen, Yang
    Yao, Peijun
    Wang, Xiaoying
    Zhang, Huihui
    Zhou, Xingtao
    ACTA OPHTHALMOLOGICA, 2021, 99 (05) : 511 - 518
  • [5] Consecutive contralateral comparison of toric and non-toric implantable collamer lenses V4c in vault after implantation for myopia and astigmatism
    Zhao, Jiao
    Zhao, Jing
    Yang, Wen
    Li, Meiyan
    Hao, Gengsheng
    Chen, Zhuoyi
    Wang, Xiaoying
    Yao, Peijun
    Zhou, Xingtao
    ACTA OPHTHALMOLOGICA, 2021, 99 (06) : E852 - E859
  • [6] Polar value analysis of astigmatic change and rotational stability after implantation of V4c toric implantable collamer lens
    Nie, Danyao
    Yan, Pisong
    Yan, Zonghui
    Zhang, Jing
    He, Wenling
    Li, Ming
    Sun, Liangnan
    Huang, Mingquan
    Liu, Xinhua
    Lin, Haotian
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (02)
  • [7] Comparison of Implantable Collamer Lens Visian ICL V4 and ICL V4c for high myopia A cohort study
    Tian, Ying
    Jiang, Hai-Bo
    Jiang, Jian
    Wen, Dan
    Xia, Xiao-Bo
    Song, Wei-Tao
    MEDICINE, 2017, 96 (25)
  • [8] Outcomes of implantable collamer lens v4 and v4c for correction of high myopia - a case series
    Karandikar, Smita
    Bhandari, Vipul
    Reddy, Jagdeesh
    NEPALESE JOURNAL OF OPHTHALMOLOGY, 2015, 7 (02) : 164 - 172
  • [9] Buffering zone of implantable Collamer lens sizing in V4c
    Nam, Seung Wan
    Lim, Dong Hui
    Hyun, Joo
    Chung, Eui-Sang
    Chung, Tae-Young
    BMC OPHTHALMOLOGY, 2017, 17
  • [10] Implantable collamer lens V4b and V4c for correction of high myopia
    Bhandari, Vipul
    Karandikar, Smitha
    Reddy, Jagdeesh K.
    Relekar, Kirti
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2015, 27 (3-4): : 76 - 81