Buffering zone of implantable Collamer lens sizing in V4c

被引:30
|
作者
Nam, Seung Wan [1 ]
Lim, Dong Hui [1 ,2 ]
Hyun, Joo [1 ,3 ]
Chung, Eui-Sang [1 ]
Chung, Tae-Young [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Dept Ophthalmol, 81 Irwon Ro, Seoul 06351, South Korea
[2] Catholic Univ Korea, Grad Sch, Dept Prevent Med, Seoul, South Korea
[3] Saevit Eye Hosp, Goyang, South Korea
来源
BMC OPHTHALMOLOGY | 2017年 / 17卷
关键词
Implantable collamer lens; Postoperative vault; Sulcus-to-sulcus diameter; PHAKIC INTRAOCULAR-LENS; WHITE-TO-WHITE; ULTRASOUND BIOMICROSCOPY; CONTACT-LENS; CENTRAL HOLE; HIGH MYOPIA; VAULT; OPACITIES; CATARACTS; DIAMETER;
D O I
10.1186/s12886-017-0663-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The purpose of this study was to identify factors related to the unexpected vault in V4c implantable collamer lens (ICL; STAAR Surgical) implantation. Methods: V4c ICLs were implanted in 43 eyes of 43 patients for the correction of myopia. The implanted V4c ICL sizes were determined individually with our previous V4 ICL sizing nomogram based on the sulcus-to-sulcus diameter (STS), and the V4 ICL sizes were then converted to V4c ICL sizes with a size-converting table. We defined the "normalsizing group" as having a pre-converted ICL size larger than the STS, and the "under-sizing group" as having a preconverted ICL size smaller than the STS. Refractive outcomes, safety and parameters related to postoperative vault were compared between the two groups. Results: The value of "actual ICL size-STS" differed significantly between the normal-sizing and under-sizing groups (p< 0.001), but postoperative vault did not differ significantly (p = 0.442). The demographics, implanted ICL characteristics, effectiveness indexes, safety indexes, and parameters related to postoperative vault did not differ significantly between the two groups (p > 0.05). Two patients in the normal-sizing group exhibited over-vaulting; these patients had shallow anterior chambers and were implanted with high-dioptric-power ICLs. Conclusions: The achievement of acceptable vault in both normal-sizing and under-sizing groups indicates the existence of a buffering zone in V4c ICL sizing. The smaller size of V4c ICLs should be considered in patients susceptible to overvaulting, such as those with shallow anterior chambers and high-dioptric-power ICLs.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Buffering zone of implantable Collamer lens sizing in V4c
    Seung Wan Nam
    Dong Hui Lim
    Joo Hyun
    Eui-Sang Chung
    Tae-Young Chung
    BMC Ophthalmology, 17
  • [2] Implantable collamer lens V4b and V4c for correction of high myopia
    Bhandari, Vipul
    Karandikar, Smitha
    Reddy, Jagdeesh K.
    Relekar, Kirti
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2015, 27 (3-4): : 76 - 81
  • [3] Outcomes of implantable collamer lens v4 and v4c for correction of high myopia - a case series
    Karandikar, Smita
    Bhandari, Vipul
    Reddy, Jagdeesh
    NEPALESE JOURNAL OF OPHTHALMOLOGY, 2015, 7 (02) : 164 - 172
  • [4] Early outcomes of anterior segment parameters after implantable collamer lens V4c implantation
    Lin, Qinghong
    Yang, Dong
    Zhou, Xingtao
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [5] Comparison of postoperative optical quality according to the degree of decentering of V4c implantable collamer lens
    Park, Min Ji
    Jeon, Hye Min
    Lee, Kyoung Heon
    Han, Sang Youp
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2017, 10 (04) : 619 - 623
  • [6] Comparison of postoperative optical quality according to the degree of decentering of V4c implantable collamer lens
    Min Ji Park
    Hye Min Jeon
    Kyoung Heon Lee
    Sang Youp Han
    International Journal of Ophthalmology, 2017, (04) : 619 - 623
  • [7] Early outcomes of anterior segment parameters after implantable collamer lens V4c implantation
    Qinghong Lin
    Dong Yang
    Xingtao Zhou
    BMC Ophthalmology, 22
  • [8] Endothelial cell loss post-implantable collamer lens V4c: meta-analysis
    Kisiel, Filip Blazej
    Gurumurthy, Gerard Jonathan
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (04): : 420 - 423
  • [9] Analysis of Inter-Eye Vault Differences After Implantable Collamer Lens (V4c) Implantation
    Tan, Xin
    Liu, Wenjie
    Chang, Ying
    Wu, Wanmin
    Yang, Lichun
    Liu, Jiewei
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2023, 16 : 2451 - 2459
  • [10] Safety and efficacy of toric implantable collamer lens V4c model - A retrospective South Indian study
    Chaitanya, S. Ravi
    Anitha, Venugopal
    Ravindran, Meenakshi
    Ghorpade, Aditya
    Rengappa, Ramakrishnan
    Uduman, Mahammed Sithiq
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (12) : 3006 - 3011