Performance evaluation of an LED flatbed scanner for triple channel film dosimetry with EBT3 and EBT-XD film

被引:4
|
作者
Van der Walt, Marchant [1 ]
Marsh, Linda [1 ]
Baines, John [1 ]
Gibson, Stephen [1 ]
Shoobridge, Ariadne [1 ]
de Vine, Glenn [1 ]
机构
[1] Townsville Hosp & Hlth Serv, Dept Med Phys, Townsville, Qld 4814, Australia
关键词
Radiochromic film dosimetry; Radiotherapy; Triple channel corrections; LED; RADIOCHROMIC FILM; DOCUMENT SCANNER; CALIBRATION;
D O I
10.1007/s13246-022-01161-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We investigate the properties of a light emitting diode (LED) flatbed scanner for use with EBT3 and EBT-XD film types in a clinical radiochromic film (RCF) dosimetry program with modern treatment techniques. The flatbed scanner was characterised in terms of lateral and longitudinal response, X-Y scaling integrity, scanning reproducibility, scanner warm up dependence and film orientation dependence. The preferred lateral response artefact (LRA) corrections are investigated for the LED light source. Supporting evidence is provided regarding the dose independent nature of the corrections while also providing results suggesting a potential film type independence. Results from 2D gamma analysis of four patient treatments were compared between the new 12000XL and existing 10000XL model. Lastly, a dose uncertainty analysis was performed for the film-scanner system combination. It may be concluded that the lateral response variation requires correction while the longitudinal response variation is insignificant. The linear scaling in the lateral and longitudinal directions are within 0.5% and the scanner reproducibility is stable. Scanner warm up dependence no longer exists, and effort should be made to maintain all film orientation in a study set within 15 degrees. The LRA corrections are as reported substantially dose independent and there is evidence to support film type independence. Comparative gamma analysis of patient specific dose maps between the EPSON 10000XL (xenon fluorescent lamp) and 12000XL (LED) scanners showed that results are indistinguishable for both film types across the two scanner models when the necessary corrections are applied. Dose uncertainty is in agreement with the literature and can be kept below 3% with necessary corrections applied.
引用
收藏
页码:901 / 914
页数:14
相关论文
共 50 条
  • [31] A characterisation of EBT3 Gafchromic film for relative and absolute dosimetry
    Billas, I.
    Bouchard, H.
    Subiel, A.
    Silvestre, I.
    Duane, S.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S414 - S414
  • [32] Accuracy and efficiency of published film dosimetry techniques using a flat-bed scanner and EBT3 film
    E. Spelleken
    S. B. Crowe
    B. Sutherland
    C. Challens
    T. Kairn
    Australasian Physical & Engineering Sciences in Medicine, 2018, 41 : 117 - 128
  • [33] Precise EBT3 Gafchromic film dosimetry for Grid therapy
    Gholami, Somayeh
    Nedaie, Hassan Ali
    Meigooni, Ali S.
    RADIATION MEASUREMENTS, 2019, 121 : 69 - 76
  • [34] Accuracy and efficiency of published film dosimetry techniques using a flat-bed scanner and EBT3 film
    Spelleken, E.
    Crowe, S. B.
    Sutherland, B.
    Challens, C.
    Kairn, T.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2018, 41 (01) : 117 - 128
  • [35] Ion beam dosimetry using Gafchromic EBT3 film
    Hassan, M. G.
    El-Saftawy, A. A.
    Soliman, B. A.
    Abdelrahman, M. M.
    Abdelmageed, K. E.
    Hassouba, M. A.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2024, 130 (06):
  • [36] Multichannel absolute film dosimetry for EBT3 GafChromic films
    Ventura, T.
    Lopes, M. C.
    Ferreira, B. C.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S169 - S169
  • [37] Radiochromic film dosimetry: Considerations on accuracy for EBT2 and EBT3 type films
    Dreindl, R.
    Georg, D.
    Stock, M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S139 - S139
  • [38] Evaluation of Uncertainties in EBT3 Film Dosimetry On An Orthovoltage Small Animal Irradiator
    Chen, Q.
    Carlton, D.
    Howard, T.
    Izumi, T.
    Molloy, J.
    MEDICAL PHYSICS, 2019, 46 (06) : E380 - E381
  • [39] Raman scattering for dosimetry using GAFCHROMIC EBT3 radiochromic dosimetry film
    Talarico, Olga S.
    Krylova, Tatyana A.
    Melnik, Nikolay N.
    MEDICAL PHYSICS, 2019, 46 (04) : 1883 - 1887
  • [40] Characterization of EBT3, EBT-XD and OC-1 Films for Absolute Dose measurement in Electron Beams
    Schott, Cathyanne
    Mansour, Imane Said
    Fournier-Bidoz, Nathalie
    Maury, Pauline
    Robert, Charlotte
    Colnot, Julie
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3266 - S3267