Transducer modeling for accurate acoustic simulations of transcranial focused ultrasound stimulation

被引:24
|
作者
Pasquinelli, Cristina [1 ,2 ,3 ]
Montanaro, Hazael [3 ,4 ,5 ]
Lee, Hyunjoo J. [6 ]
Hanson, Lars G. [1 ,2 ]
Kim, Hyungkook [6 ]
Kuster, Niels [4 ,5 ]
Siebner, Hartwig R. [1 ,7 ]
Neufeld, Esra [4 ]
Thielscher, Axel [1 ,2 ]
机构
[1] Copenhagen Univ Hosp Hvidovre, Danish Res Ctr Magnet Resonance, Ctr Funct & Diagnost Imaging & Res, Hvidovre, Denmark
[2] Tech Univ Denmark, Dept Hlth Technol, Ctr Magnet Resonance, Lyngby, Denmark
[3] Fdn Res Informat Technol Soc ITIS, Zurich, Switzerland
[4] Swiss Fed Inst Technol, Dept Informat Technol & Elect Engn, Zurich, Switzerland
[5] Korea Adv Inst Sci & Technol, Sch Elect Engn, Daejeon, South Korea
[6] Copenhagen Univ Hosp Bispebjerg, Dept Neurol, Copenhagen, Denmark
[7] Univ Copenhagen, Inst Clin Med, Fac Hlth & Med Sci, Copenhagen, Denmark
关键词
transcranial focused ultrasound stimulation; single element focused transducer; finite difference time domain; computational dosimetry; gamma method; FREQUENCY-DEPENDENCE; SPEED; SOUND; TRANSMISSION; ATTENUATION;
D O I
10.1088/1741-2552/ab98dc
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Low-intensity transcranial ultrasound stimulation (TUS) is emerging as a non-invasive brain stimulation technique with superior spatial resolution and the ability to reach deep brain areas. Medical image-based computational modeling could be an important tool for individualized TUS dose control and targeting optimization, but requires further validation. This study aims to assess the impact of the transducer model on the accuracy of the simulations.Approach. Using hydrophone measurements, the acoustic beam of a single-element focused transducer (SEFT) with a flat piezoelectric disc and an acoustic lens was characterized. The acoustic beam was assessed in a homogeneous water bath and after transmission through obstacles (3D-printed shapes and skull samples). The acoustic simulations employed the finite-difference time-domain method and were informed by computed tomography (CT) images of the obstacles. Transducer models of varying complexity were tested representing the SEFT either as a surface boundary condition with variable curvature or also accounting for its internal geometry. In addition, a back-propagated pressure distribution from the first measurement plane was used as source model. The simulations and measurements were quantitatively compared using key metrics for peak location, focus size, intensity and spatial distribution.Main results. While a surface boundary with an adapted, 'effective' curvature radius based on the specifications given by the manufacturer could reproduce the measured focus location and size in a homogeneous water bath, it regularly failed to accurately predict the beam after obstacle transmission. In contrast, models that were based on a one-time calibration to the homogeneous water bath measurements performed substantially better in all cases with obstacles. For one of the 3D-printed obstacles, the simulated intensities deviated substantially from the measured ones, irrespective of the transducer model. We attribute this finding to a standing wave effect, and further studies should clarify its relevance for accurate simulations of skull transmission.Significance. Validated transducer models are important to ensure accurate simulations of the acoustic beam of SEFTs, in particular in the presence of obstacles such as the skull.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] An efficient and accurate parallel hybrid acoustic signal correction method for transcranial ultrasound
    Wu, Nan
    Shen, Guofeng
    Qu, Xiongfei
    Wu, Hao
    Qiao, Shan
    Wang, Enmin
    Chen, Yazhu
    Wang, Han
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (21):
  • [42] An accurate coupled method for analysis of transcranial magneto-acoustic-electrical stimulation
    Wang, Z. H.
    Shang, K.
    Wang, G.
    APPLIED MATHEMATICAL MODELLING, 2024, 128 : 470 - 491
  • [43] Focused ultrasound transducer for thermal treatment
    Umemura, Shin-ichiro
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2015, 31 (02) : 216 - 221
  • [44] Computational optimization of transcranial focused ultrasound stimulation: Toward noninvasive, selective stimulation of deep brain structures
    De Angelis, A.
    Leonetti, M.
    Apollonio, F.
    Liberti, M.
    Aglioti, S. M.
    Ruocco, G.
    APPLIED PHYSICS LETTERS, 2021, 118 (23)
  • [45] Acoustic Simulation for Transcranial Focused Ultrasound Using GAN-Based Synthetic CT
    Koh, Heekyung
    Park, Tae Young
    Chung, Yong An
    Lee, Jong-Hwan
    Kim, Hyungmin
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (01) : 161 - 171
  • [46] Improved skull bone acoustic property homogenization for fast transcranial ultrasound simulations
    Angla, Celestine
    Larrat, Benoit
    Gennisson, Jean-Luc
    Chatillon, Sylvain
    20TH ANGLO-FRENCH PHYSICAL ACOUSTICS CONFERENCE, AFPAC 2023, 2024, 2768
  • [47] PREDICTION OF THE SKULL'S ACOUSTIC PARAMETERS IN TRANSCRANIAL FOCUSED ULTRASOUND BASED ON NEURAL NETWORK
    Wang, Xiang-da
    Li, Nan-xing
    Lin, Wei-jun
    Su, Chang
    PROCEEDINGS OF 2016 SYMPOSIUM ON PIEZOELECTRICITY, ACOUSTIC WAVES, AND DEVICE APPLICATIONS (SPAWDA), 2016, : 123 - 126
  • [48] Precise control of ultrasound stimulation/treatment by a high-frequency focused ring transducer
    Kim, Hyunhee
    Yoo, Jinhee
    Lim, Hae Gyun
    Kim, Hyung Ham
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [49] Head phantoms for transcranial focused ultrasound
    Eames, Matthew D. C.
    Farnum, Mercy
    Khaled, Mohamad
    Elias, W. Jeff
    Hananel, Arik
    Snell, John W.
    Kassell, Neal F.
    Aubry, Jean-Francois
    MEDICAL PHYSICS, 2015, 42 (04) : 1518 - 1527
  • [50] Transcranial ultrasound simulations: A review
    Angla, Celestine
    Larrat, Benoit
    Gennisson, Jean-Luc
    Chatillon, Sylvain
    MEDICAL PHYSICS, 2023, 50 (02) : 1051 - 1072