Transducer modeling for accurate acoustic simulations of transcranial focused ultrasound stimulation

被引:24
|
作者
Pasquinelli, Cristina [1 ,2 ,3 ]
Montanaro, Hazael [3 ,4 ,5 ]
Lee, Hyunjoo J. [6 ]
Hanson, Lars G. [1 ,2 ]
Kim, Hyungkook [6 ]
Kuster, Niels [4 ,5 ]
Siebner, Hartwig R. [1 ,7 ]
Neufeld, Esra [4 ]
Thielscher, Axel [1 ,2 ]
机构
[1] Copenhagen Univ Hosp Hvidovre, Danish Res Ctr Magnet Resonance, Ctr Funct & Diagnost Imaging & Res, Hvidovre, Denmark
[2] Tech Univ Denmark, Dept Hlth Technol, Ctr Magnet Resonance, Lyngby, Denmark
[3] Fdn Res Informat Technol Soc ITIS, Zurich, Switzerland
[4] Swiss Fed Inst Technol, Dept Informat Technol & Elect Engn, Zurich, Switzerland
[5] Korea Adv Inst Sci & Technol, Sch Elect Engn, Daejeon, South Korea
[6] Copenhagen Univ Hosp Bispebjerg, Dept Neurol, Copenhagen, Denmark
[7] Univ Copenhagen, Inst Clin Med, Fac Hlth & Med Sci, Copenhagen, Denmark
关键词
transcranial focused ultrasound stimulation; single element focused transducer; finite difference time domain; computational dosimetry; gamma method; FREQUENCY-DEPENDENCE; SPEED; SOUND; TRANSMISSION; ATTENUATION;
D O I
10.1088/1741-2552/ab98dc
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Low-intensity transcranial ultrasound stimulation (TUS) is emerging as a non-invasive brain stimulation technique with superior spatial resolution and the ability to reach deep brain areas. Medical image-based computational modeling could be an important tool for individualized TUS dose control and targeting optimization, but requires further validation. This study aims to assess the impact of the transducer model on the accuracy of the simulations.Approach. Using hydrophone measurements, the acoustic beam of a single-element focused transducer (SEFT) with a flat piezoelectric disc and an acoustic lens was characterized. The acoustic beam was assessed in a homogeneous water bath and after transmission through obstacles (3D-printed shapes and skull samples). The acoustic simulations employed the finite-difference time-domain method and were informed by computed tomography (CT) images of the obstacles. Transducer models of varying complexity were tested representing the SEFT either as a surface boundary condition with variable curvature or also accounting for its internal geometry. In addition, a back-propagated pressure distribution from the first measurement plane was used as source model. The simulations and measurements were quantitatively compared using key metrics for peak location, focus size, intensity and spatial distribution.Main results. While a surface boundary with an adapted, 'effective' curvature radius based on the specifications given by the manufacturer could reproduce the measured focus location and size in a homogeneous water bath, it regularly failed to accurately predict the beam after obstacle transmission. In contrast, models that were based on a one-time calibration to the homogeneous water bath measurements performed substantially better in all cases with obstacles. For one of the 3D-printed obstacles, the simulated intensities deviated substantially from the measured ones, irrespective of the transducer model. We attribute this finding to a standing wave effect, and further studies should clarify its relevance for accurate simulations of skull transmission.Significance. Validated transducer models are important to ensure accurate simulations of the acoustic beam of SEFTs, in particular in the presence of obstacles such as the skull.
引用
收藏
页数:22
相关论文
共 50 条
  • [31] Ventricle stimulation as a potential gold-standard control stimulation site for transcranial focused ultrasound stimulation
    Atkinson-Clement, Cyril
    Kaiser, Marcus
    Ralph, Matthew A. Lambon
    Jung, Jeyoung
    BRAIN STIMULATION, 2024, 17 (06) : 1328 - 1330
  • [32] High Intensity Focused Ultrasound (HIFU) transducer characterization using acoustic streaming
    Hariharan, Prasanna
    Robinson, Ronald A.
    Myers, Matthew R.
    Banerjee, Rupak K.
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 757 - 758
  • [33] Neuromodulation with transcranial focused ultrasound
    Kubanek, Jan
    NEUROSURGICAL FOCUS, 2018, 44 (02)
  • [34] Modeling of Shock Wave Generated from a Strong Focused Ultrasound Transducer
    Chen Tao
    Qiu Yuan-Yuan
    Fan Ting-Bo
    Zhang Dong
    CHINESE PHYSICS LETTERS, 2013, 30 (07)
  • [35] Modeling of Shock Wave Generated from a Strong Focused Ultrasound Transducer
    陈涛
    邱媛媛
    范庭波
    章东
    Chinese Physics Letters, 2013, 30 (07) : 120 - 123
  • [36] Numerical Investigation of Layered Homogeneous Skull Model for Simulations of Transcranial Focused Ultrasound
    Seo, Hyeon
    Han, Mun
    Choi, Jong-ryul
    Kim, Seungmin
    Park, Juyoung
    Lee, Eun-Hee
    NEUROMODULATION, 2025, 28 (01): : 103 - 114
  • [37] Transcranial measurements of the acoustic field produced by a low frequency focused ultrasound system
    Voie, Arne
    Fisher, David
    Ahadi, Golnaz
    Hoelscher, Thilo
    12TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2012, 1503 : 256 - 263
  • [38] Predicting Bone Marrow Damage in the Skull After Clinical Transcranial MRI-Guided Focused Ultrasound With Acoustic and Thermal Simulations
    McDannold, Nathan
    White, P. Jason
    Cosgrove, Rees
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (10) : 3231 - 3239
  • [39] Effects of sonication parameters on transcranial focused ultrasound brain stimulation in an ovine model
    Yoon, Kyungho
    Lee, Wonhye
    Lee, Ji Eun
    Xu, Linda
    Croce, Phillip
    Foley, Lori
    Yoo, Seung-Schik
    PLOS ONE, 2019, 14 (10):
  • [40] Development of a Wearable Robotic Positioning System for Noninvasive Transcranial Focused Ultrasound Stimulation
    Kim, Junwoo
    Lee, Sungon
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2016, 21 (05) : 2284 - 2293