High Intensity Focused Ultrasound (HIFU) transducer characterization using acoustic streaming

被引:0
|
作者
Hariharan, Prasanna [1 ]
Robinson, Ronald A.
Myers, Matthew R.
Banerjee, Rupak K. [1 ]
机构
[1] Univ Cincinnati, Dept Mech Ind & Nucl Engn, Cincinnati, OH 45220 USA
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A new, non-perturbing optical measurement technique was developed to characterize medical ultrasound fields generated by High Intensity Focused Ultrasound (HFU) transducers using a phenomenon called 'acoustic streaming'. The acoustic streaming velocity generated by HIFU transducers was measured experimentally using Digital Particle Image Velocimetry (DPIV). The streaming velocity was then calculated numerically using the finite-element method. An optimization algorithm was developed to back-calculate acoustic power and intensity field by minimizing the difference between experimental and numerical streaming velocities. The intensity field and acoustic power calculated using this approach was validated with standard measurement techniques. Results showed that the inverse method was able to predict acoustic power and intensity fields within 10% of the actual value measured using standard techniques, at the low powers where standard methods can be safely applied. This technique is also potentially useful for evaluating medical ultrasound transducers at the higher power levels used in clinical practice.
引用
收藏
页码:757 / 758
页数:2
相关论文
共 50 条
  • [1] Characterization of high intensity focused ultrasound transducers using acoustic streaming
    Hariharan, Prasanna
    Myers, Matthew R.
    Robinson, Ronald A.
    Maruvada, Subha H.
    Sliwa, Jack
    Banerjee, Rupak K.
    Journal of the Acoustical Society of America, 2008, 123 (03): : 1706 - 1719
  • [2] Characterization of high intensity focused ultrasound transducers using acoustic streaming
    Hariharan, Prasanna
    Myers, Matthew R.
    Robinson, Ronald A.
    Maruvada, Subha H.
    Sliwa, Jack
    Banerjee, Rupak K.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2008, 123 (03): : 1706 - 1719
  • [3] Using the acoustic interference pattern to locate the focus of a high-intensity focused ultrasound (HIFU) transducer
    Wu, Chih-Ching
    Chen, Chiung-Nien
    Ho, Ming-Chih
    Chen, Wen-Shiang
    Lee, Po-Huang
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (01): : 137 - 146
  • [4] Optimization of Phase Shift of the Transducer for High Intensity Focused Ultrasound (HIFU)
    Yamamoto, Mariko
    Yoshizawa, Shin
    Umemura, Shin-ichiro
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 1625 - 1628
  • [5] Coagulation Using High Intensity Focused Ultrasound (HIFU)
    Nguyen, Phuc V.
    Oh, Junghwan
    Kang, Hyun Wook
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS X, 2014, 8926
  • [6] High intensity focused ultrasound (HIFU)
    Barkin, Jack
    CANADIAN JOURNAL OF UROLOGY, 2011, 18 (02) : 5634 - 5643
  • [7] High intensity focused ultrasound (HIFU)
    Ganzer, R.
    RADIOLOGE, 2017, 57 (08): : 659 - 664
  • [8] Theoretically Estimating the Acoustic Intensity of High-Intensity Focused Ultrasound (HIFU) Using Infrared Thermography
    Zhou, Yufeng
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (06) : 1159 - 1165
  • [9] Development of a high intensity focused ultrasound (HIFU) transducer suitable for endoscopic applications.
    Prat, F
    Chapelon, JY
    Arefiev, A
    Theilliere, Y
    Cathignol, D
    GASTROENTEROLOGY, 1996, 110 (04) : A578 - A578
  • [10] Acoustic power measurement of high-intensity focused ultrasound transducer using a pressure sensor
    Zhou, Yufeng
    MEDICAL ENGINEERING & PHYSICS, 2015, 37 (03) : 335 - 340