Head phantoms for transcranial focused ultrasound

被引:16
|
作者
Eames, Matthew D. C. [1 ]
Farnum, Mercy [1 ]
Khaled, Mohamad [2 ]
Elias, W. Jeff [2 ]
Hananel, Arik [1 ,3 ]
Snell, John W. [1 ,2 ]
Kassell, Neal F. [1 ,2 ]
Aubry, Jean-Francois [3 ,4 ]
机构
[1] Focused Ultrasound Fdn, Charlottesville, VA 22903 USA
[2] Univ Virginia, Dept Neurosurg, Charlottesville, VA 22908 USA
[3] Univ Virginia, Dept Radiat Oncol, Charlottesville, VA 22908 USA
[4] ESPCI ParisTech, Inst Langevin, CNRS UMR 7587, INSERM,U979, F-75005 Paris, France
关键词
head phantom; focused ultrasound; tcMRgFUS; brain; treatment envelope; TISSUE-MIMICKING MATERIAL; MAGNETIC-RESONANCE; ESSENTIAL TREMOR; SURGERY; THERAPY; BRAIN; FEASIBILITY; RELIABILITY; THALAMOTOMY; ABLATION;
D O I
10.1118/1.4907959
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In the ongoing endeavor of fine-tuning, the clinical application of transcranial MR-guided focused ultrasound (tcMRgFUS), ex-vivo studies wlkiith whole human skulls are of great use in improving the underlying technology guiding the accurate and precise thermal ablation of clinically relevant targets in the human skull. Described here are the designs, methods for fabrication, and notes on utility of three different ultrasound phantoms to be used for brain focused ultrasound research. Methods: Three different models of phantoms are developed and tested to be accurate, repeatable experimental options to provide means to further this research. The three models are a cadaver, a gel-filled skull, and a head mold containing a skull and filled with gel that mimics the brain and the skin. Each was positioned in a clinical tcMRgFUS system and sonicated at 1100 W (acoustic) for 12 s at different locations. Maximum temperature rise as measured by MR thermometry was recorded and compared against clinical data for a similar neurosurgical target. Results are presented as heating efficiency in units (degrees C/kW/s) for direct comparison to available clinical data. The procedure for casting thermal phantom material is presented. The utility of each phantom model is discussed in the context of various tcMRgFUS research areas. Results: The cadaveric phantom model, gel-filled skull model, and full head phantom model had heating efficiencies of 5.3, 4.0, and 3.9 degrees C/(kW/s), respectively, compared to a sample clinical heating efficiency of 2.6 degrees C/(kW/s). In the seven research categories considered, the cadaveric phantom model was the most versatile, though less practical compared to the ex-vivo skull-based phantoms. Conclusions: Casting thermal phantom material was shown to be an effective way to prepare tissue-mimicking material for the phantoms presented. The phantom models presented are all useful in tcMRgFUS research, though some are better suited to a limited subset of applications depending on the researchers needs. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:1518 / 1527
页数:10
相关论文
共 50 条
  • [1] Investigation of Transcranial Focused Ultrasound Attenuation with Multilayer Head Model
    Song, Xizi
    Guo, Jiande
    Chen, Xinrui
    Ke, Yufeng
    Ming, Dong
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [2] Numerical Simulation of Transcranial Focused Ultrasound Based on Head CT images
    Andrade, Patricia C.
    Kamimura, Hermes A. S.
    Costa, Eduardo T.
    17TH INTERNATIONAL SYMPOSIUM ON MEDICAL INFORMATION PROCESSING AND ANALYSIS, 2021, 12088
  • [3] A head template for computational dose modelling for transcranial focused ultrasound stimulation
    Hosseini, Seyedsina
    Puonti, Oula
    Treeby, Bradley
    Hanson, Lars G.
    Thielscher, Axel
    NEUROIMAGE, 2023, 277
  • [4] Neuromodulation with transcranial focused ultrasound
    Kubanek, Jan
    NEUROSURGICAL FOCUS, 2018, 44 (02)
  • [5] Image-guided Application and Monitoring of Transcranial Focused Ultrasound in Realistic Human Head Phantom
    O'Brien, P. D.
    Smith, Collin S.
    Ebbini, Emad S.
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1898 - 1901
  • [6] MR-Guided Transcranial Focused Ultrasound
    Aubry, Jean-Francois
    Tanter, Mickael
    THERAPEUTIC ULTRASOUND, 2016, 880 : 97 - 111
  • [7] A PVDF Receiver for Ultrasound Monitoring of Transcranial Focused Ultrasound Therapy
    O'Reilly, Meaghan A.
    Hynynen, Kullervo
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (09) : 2286 - 2294
  • [8] Transcranial Focused Ultrasound A History of Our Future
    Ahmed, Abdul-Kareem
    Woodworth, Graeme F.
    Gandhi, Dheeraj
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2024, 32 (04) : 585 - 592
  • [9] Focused transcranial ultrasound for treatment of neurodegenerative dementia
    Nicodemus, Natalie Eleanor
    Becerra, Sergio
    Kuhn, Taylor P.
    Packham, Hannah R.
    Duncan, John
    Mahdavi, Kennedy
    Iovine, Jessica
    Kesari, Santosh
    Pereles, Scott
    Whitney, Mike
    Mamoun, Michael
    Franc, Daniel
    Bystritsky, Alexander
    Jordan, Sheldon
    ALZHEIMERS & DEMENTIA-TRANSLATIONAL RESEARCH & CLINICAL INTERVENTIONS, 2019, 5 (01) : 374 - 381
  • [10] THE EFFECTS OF TRANSCRANIAL FOCUSED ULTRASOUND ON ALPHA POWER
    Shlimovitz, Eli
    Lord, Brian
    Fife, Eliana
    Allen, John
    PSYCHOPHYSIOLOGY, 2024, 61 : S94 - S94