Head phantoms for transcranial focused ultrasound

被引:16
|
作者
Eames, Matthew D. C. [1 ]
Farnum, Mercy [1 ]
Khaled, Mohamad [2 ]
Elias, W. Jeff [2 ]
Hananel, Arik [1 ,3 ]
Snell, John W. [1 ,2 ]
Kassell, Neal F. [1 ,2 ]
Aubry, Jean-Francois [3 ,4 ]
机构
[1] Focused Ultrasound Fdn, Charlottesville, VA 22903 USA
[2] Univ Virginia, Dept Neurosurg, Charlottesville, VA 22908 USA
[3] Univ Virginia, Dept Radiat Oncol, Charlottesville, VA 22908 USA
[4] ESPCI ParisTech, Inst Langevin, CNRS UMR 7587, INSERM,U979, F-75005 Paris, France
关键词
head phantom; focused ultrasound; tcMRgFUS; brain; treatment envelope; TISSUE-MIMICKING MATERIAL; MAGNETIC-RESONANCE; ESSENTIAL TREMOR; SURGERY; THERAPY; BRAIN; FEASIBILITY; RELIABILITY; THALAMOTOMY; ABLATION;
D O I
10.1118/1.4907959
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In the ongoing endeavor of fine-tuning, the clinical application of transcranial MR-guided focused ultrasound (tcMRgFUS), ex-vivo studies wlkiith whole human skulls are of great use in improving the underlying technology guiding the accurate and precise thermal ablation of clinically relevant targets in the human skull. Described here are the designs, methods for fabrication, and notes on utility of three different ultrasound phantoms to be used for brain focused ultrasound research. Methods: Three different models of phantoms are developed and tested to be accurate, repeatable experimental options to provide means to further this research. The three models are a cadaver, a gel-filled skull, and a head mold containing a skull and filled with gel that mimics the brain and the skin. Each was positioned in a clinical tcMRgFUS system and sonicated at 1100 W (acoustic) for 12 s at different locations. Maximum temperature rise as measured by MR thermometry was recorded and compared against clinical data for a similar neurosurgical target. Results are presented as heating efficiency in units (degrees C/kW/s) for direct comparison to available clinical data. The procedure for casting thermal phantom material is presented. The utility of each phantom model is discussed in the context of various tcMRgFUS research areas. Results: The cadaveric phantom model, gel-filled skull model, and full head phantom model had heating efficiencies of 5.3, 4.0, and 3.9 degrees C/(kW/s), respectively, compared to a sample clinical heating efficiency of 2.6 degrees C/(kW/s). In the seven research categories considered, the cadaveric phantom model was the most versatile, though less practical compared to the ex-vivo skull-based phantoms. Conclusions: Casting thermal phantom material was shown to be an effective way to prepare tissue-mimicking material for the phantoms presented. The phantom models presented are all useful in tcMRgFUS research, though some are better suited to a limited subset of applications depending on the researchers needs. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:1518 / 1527
页数:10
相关论文
共 50 条
  • [21] Advances in transcranial focused ultrasound neuromodulation for mental disorders
    Shi, Yu
    Wu, Wen
    PROGRESS IN NEURO-PSYCHOPHARMACOLOGY & BIOLOGICAL PSYCHIATRY, 2025, 136
  • [22] Effects of parameter errors in the simulation of transcranial focused ultrasound
    Vaughan, TE
    Hynynen, K
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (01): : 37 - 45
  • [23] A rapid beam simulation framework for transcranial focused ultrasound
    Steven A. Leung
    Taylor D. Webb
    Rachelle R. Bitton
    Pejman Ghanouni
    Kim Butts Pauly
    Scientific Reports, 9
  • [24] Research and Application of Transcranial Focused Ultrasound Simulation Methods
    Chen, Guo-Wei
    Wang, Xue
    He, Feng
    Zhang, Hao
    Xu, Min-Peng
    Ming, Dong
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2025, 52 (03) : 691 - 704
  • [25] A rapid beam simulation framework for transcranial focused ultrasound
    Leung, Steven A.
    Webb, Taylor D.
    Bitton, Rachelle R.
    Ghanouni, Pejman
    Pauly, Kim Butts
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [26] Current and future uses of transcranial focused ultrasound in neurosurgery
    Hersh, David S.
    Eisenberg, Howard M.
    JOURNAL OF NEUROSURGICAL SCIENCES, 2018, 62 (02) : 203 - 213
  • [27] Transcranial Focused Ultrasound for Noninvasive Neuromodulation of the Visual Cortex
    Lu, Gengxi
    Qian, Xuejun
    Castillo, Johnny
    Li, Runze
    Jiang, Laiming
    Lu, Haotian
    Shung, K. Kirk
    Humayun, Mark S.
    Thomas, Biju B.
    Zhou, Qifa
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (01) : 21 - 28
  • [28] Noninvasive Focused Monitoring and Irradiation of Head Tissue Phantoms at Microwave Frequencies
    Karathanasis, Konstantinos T.
    Gouzouasis, Ioannis A.
    Karanasiou, Irene S.
    Giamalaki, Melpomeni I.
    Stratakos, George
    Uzunoglu, Nikolaos K.
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (03): : 657 - 663
  • [29] Reusable tissue-mimicking hydrogel phantoms for focused ultrasound ablation
    Sun, Ming-Kuan
    Shieh, Jay
    Lo, Chia-Wen
    Chen, Chuin-Shan
    Chen, Ben-Ting
    Huang, Chang-Wei
    Chen, Wen-Shiang
    ULTRASONICS SONOCHEMISTRY, 2015, 23 : 399 - 405
  • [30] Transcranial Focused Ultrasound (tFUS) and Transcranial Unfocused Ultrasound (tUS) Neuromodulation: From Theoretical Principles to Stimulation Practices
    di Biase, Lazzaro
    Falato, Emma
    Di Lazzaro, Vincenzo
    FRONTIERS IN NEUROLOGY, 2019, 10