Head phantoms for transcranial focused ultrasound

被引:16
|
作者
Eames, Matthew D. C. [1 ]
Farnum, Mercy [1 ]
Khaled, Mohamad [2 ]
Elias, W. Jeff [2 ]
Hananel, Arik [1 ,3 ]
Snell, John W. [1 ,2 ]
Kassell, Neal F. [1 ,2 ]
Aubry, Jean-Francois [3 ,4 ]
机构
[1] Focused Ultrasound Fdn, Charlottesville, VA 22903 USA
[2] Univ Virginia, Dept Neurosurg, Charlottesville, VA 22908 USA
[3] Univ Virginia, Dept Radiat Oncol, Charlottesville, VA 22908 USA
[4] ESPCI ParisTech, Inst Langevin, CNRS UMR 7587, INSERM,U979, F-75005 Paris, France
关键词
head phantom; focused ultrasound; tcMRgFUS; brain; treatment envelope; TISSUE-MIMICKING MATERIAL; MAGNETIC-RESONANCE; ESSENTIAL TREMOR; SURGERY; THERAPY; BRAIN; FEASIBILITY; RELIABILITY; THALAMOTOMY; ABLATION;
D O I
10.1118/1.4907959
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In the ongoing endeavor of fine-tuning, the clinical application of transcranial MR-guided focused ultrasound (tcMRgFUS), ex-vivo studies wlkiith whole human skulls are of great use in improving the underlying technology guiding the accurate and precise thermal ablation of clinically relevant targets in the human skull. Described here are the designs, methods for fabrication, and notes on utility of three different ultrasound phantoms to be used for brain focused ultrasound research. Methods: Three different models of phantoms are developed and tested to be accurate, repeatable experimental options to provide means to further this research. The three models are a cadaver, a gel-filled skull, and a head mold containing a skull and filled with gel that mimics the brain and the skin. Each was positioned in a clinical tcMRgFUS system and sonicated at 1100 W (acoustic) for 12 s at different locations. Maximum temperature rise as measured by MR thermometry was recorded and compared against clinical data for a similar neurosurgical target. Results are presented as heating efficiency in units (degrees C/kW/s) for direct comparison to available clinical data. The procedure for casting thermal phantom material is presented. The utility of each phantom model is discussed in the context of various tcMRgFUS research areas. Results: The cadaveric phantom model, gel-filled skull model, and full head phantom model had heating efficiencies of 5.3, 4.0, and 3.9 degrees C/(kW/s), respectively, compared to a sample clinical heating efficiency of 2.6 degrees C/(kW/s). In the seven research categories considered, the cadaveric phantom model was the most versatile, though less practical compared to the ex-vivo skull-based phantoms. Conclusions: Casting thermal phantom material was shown to be an effective way to prepare tissue-mimicking material for the phantoms presented. The phantom models presented are all useful in tcMRgFUS research, though some are better suited to a limited subset of applications depending on the researchers needs. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:1518 / 1527
页数:10
相关论文
共 50 条
  • [41] Transcranial focused ultrasound stimulation of human primary visual cortex
    Lee, Wonhye
    Kim, Hyun-Chul
    Jung, Yujin
    Chung, Yong An
    Song, In-Uk
    Lee, Jong-Hwan
    Yoo, Seung-Schik
    SCIENTIFIC REPORTS, 2016, 6
  • [42] Transcranial Clot Lysis Using High Intensity Focused Ultrasound
    Holscher, Thilo
    Zadicario, Eyal
    Fisher, David J.
    Bradley, William G.
    9TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2010, 1215 : 23 - +
  • [43] On the neuromodulatory pathways of the in vivo brain by means of transcranial focused ultrasound
    Niu, Xiaodan
    Yu, Kai
    He, Bin
    CURRENT OPINION IN BIOMEDICAL ENGINEERING, 2018, 8 : 61 - 69
  • [44] Transcranial focused ultrasound stimulation of human primary visual cortex
    Wonhye Lee
    Hyun-Chul Kim
    Yujin Jung
    Yong An Chung
    In-Uk Song
    Jong-Hwan Lee
    Seung-Schik Yoo
    Scientific Reports, 6
  • [45] The promise of transcranial focused ultrasound in disorders of consciousness: a narrative review
    Yang, Dongdong
    Fu, Shengqi
    Zhao, Meng
    Shi, Yu
    CRITICAL CARE, 2025, 29 (01)
  • [46] Transcranial focused ultrasound neuromodulation of the human primary motor cortex
    Legon, Wynn
    Bansal, Priya
    Tyshynsky, Roman
    Ai, Leo
    Mueller, Jerel K.
    SCIENTIFIC REPORTS, 2018, 8
  • [47] Transcranial focused ultrasound neuromodulation of the human primary motor cortex
    Wynn Legon
    Priya Bansal
    Roman Tyshynsky
    Leo Ai
    Jerel K. Mueller
    Scientific Reports, 8
  • [48] Transcranial Focused Ultrasound for BOLD fMRI Signal Modulation in Humans
    Ai, Leo
    Mueller, Jerel K.
    Grant, Andrea
    Eryaman, Yigitcan
    Legon, Wynn
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 1758 - 1761
  • [49] DEVELOPMENT OF TOUGH HYDROGEL PHANTOMS TO MIMIC FIBROUS TISSUE FOR FOCUSED ULTRASOUND THERAPIES
    Kumar, Yashwanth Nanda
    Singh, Zorawar
    Wang, Yak-Nam
    Schade, George R.
    Kreider, Wayne
    Bruce, Matthew
    Vlaisavljevich, Eli
    Khokhlova, Tatiana D.
    Maxwell, Adam D.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (09): : 1762 - 1777
  • [50] Excitation and detection of shear waves inside biological tissue phantoms by focused ultrasound
    Andreev, V.G.
    Ultrasound in Medicine and Biology, 2000, 26 (SUPPL. 2):