Evaluation of focused multipolar stimulation for cochlear implants in long-term deafened cats

被引:31
|
作者
George, Shefin S. [1 ,2 ]
Wise, Andrew K. [1 ,2 ]
Fallon, James B. [1 ,2 ]
Shepherd, Robert K. [1 ,2 ]
机构
[1] Bion Inst, East Melbourne 3002, Australia
[2] Univ Melbourne, Dept Med Bion, Melbourne, Vic 3002, Australia
基金
澳大利亚国家健康与医学研究理事会;
关键词
cochlear implant; current focusing; electrode configuration; spatial tuning curve; inferior colliculus; deafness; ELECTRICAL-STIMULATION; SPIRAL GANGLION; SPATIAL SELECTIVITY; SPEECH RECOGNITION; INFERIOR COLLICULUS; SPECTRAL CHANNELS; AUDITORY-NERVE; TRIPOLAR; PERCEPTION; EXCITATION;
D O I
10.1088/1741-2560/12/3/036003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Focused multipolar (FMP) stimulation has been shown to produce restricted neural activation using intracochlear stimulation in animals with a normal population of spiral ganglion neurons (SGNs). However, in a clinical setting, the widespread loss of SGNs and peripheral fibres following deafness is expected to influence the effectiveness of FMP. Approach. We compared the efficacy of FMP stimulation to both monopolar (MP) and tripolar (TP) stimulation in long-term deafened cat cochleae (n = 8). Unlike our previous study, these cochleae contained <10% of the normal SGN population adjacent to the electrode array. We also evaluated the effect of electrode position on stimulation modes by using either modiolar facing or lateral wall facing half-band electrodes. The spread of neural activity across the inferior colliculus, a major nucleus within the central auditory pathway, was used as a measure of spatial selectivity. Main results. In cochleae with significant SGN degeneration, we observed that FMP and TP stimulation resulted in greater spatial selectivity than MP stimulation (p < 0.001). However, thresholds were significantly higher for FMP and TP stimulation compared to MP stimulation (p < 0.001). No difference between FMP and TP stimulation was found in any measures. The high threshold levels for FMP stimulation was significantly reduced without compromising spatial selectivity by varying the degree of current focusing (referred as 'partial-FMP' stimulation). Spatial selectivity of all stimulation modes was unaffected by the electrode position. Finally, spatial selectivity in long-term deafened cochleae was significantly less than that of cochleae with normal SGN population (George S S et al 2014 J. Neural Eng. 11 065003). Significance. The present results indicate that the greater spatial selectivity of FMP and TP stimulation over MP stimulation is maintained in cochleae with significant neural degeneration and is not adversely affected by electrode position. The greater spatial selectivity of FMP and TP stimulation would be expected to result in improved clinical performance.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Effectiveness of cochlear implants in children: Long term results
    Peixoto, Maria Conceicao
    Spratley, Jorge
    Oliveira, Guiomar
    Martins, Jorge
    Bastos, Jose
    Ribeiro, Carlos
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2013, 77 (04) : 462 - 468
  • [42] Long-term outcome on spoken word recognition ability of young children with cochlear implants
    Lee, KYS
    van Hasselt, CA
    COCHLEAR IMPLANTS, 2004, 1273 : 300 - 303
  • [43] Long-term outcomes and electrophysiological measures of children with inner ear malformations and cochlear implants
    Sokolov, Meirav
    Raveh, Eyal
    Yaniv, Dan
    Reuven, Yonatan
    Ulanovski, David
    Barkan, Neta
    Greenstein, Tally
    Lipshitz, Noga
    Attias, Joseph
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2024, 178
  • [44] Nonword Repetition as a Predictor of Long-Term Speech and Language Skills in Children With Cochlear Implants
    Casserly, Elizabeth D.
    Pisoni, David B.
    OTOLOGY & NEUROTOLOGY, 2013, 34 (03) : 460 - 470
  • [45] Executive Functioning Skills in Long-Term Users of Cochlear Implants: A Case Control Study
    Kronenberger, William G.
    Pisoni, David B.
    Henning, Shirley C.
    Colson, Bethany G.
    JOURNAL OF PEDIATRIC PSYCHOLOGY, 2013, 38 (08) : 902 - 914
  • [46] Optical cochlear implants: Evaluation of surgical approach and laser parameters in cats
    Rajguru, Suhrud M.
    Matic, Agnella Izzo
    Robinson, Alan M.
    Fishman, Andrew J.
    Moreno, Laura E.
    Bradley, Allison
    Vujanovic, Irena
    Breen, Joe
    Wells, Jonathon D.
    Bendett, Mark
    Richter, Claus-Peter
    HEARING RESEARCH, 2010, 269 (1-2) : 102 - 111
  • [47] Long-term evaluation of osseointegrated implants in regenerated and nonregenerated bone
    Corrente, G
    Abundo, R
    Cardaropoli, D
    Cardaropoli, G
    Martuscelli, G
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2000, 20 (04) : 391 - 397
  • [48] Audiometric evaluation short and medium term in cochlear implants
    Alonso-Lujan, Laura R.
    Gutiérrez-Farfán, Ileana
    Luna-Reyes, Francisco A.
    Chamlati-Aguirre, Laura E.
    Durand Rivera, Alfredo
    REVISTA DE INVESTIGACION CLINICA-CLINICAL AND TRANSLATIONAL INVESTIGATION, 2014, 66 (05): : 415 - 421
  • [49] Long-term evaluation of deep brain stimulation of the thalamus
    Pahwa, R
    Lyons, KE
    Wilkinson, SB
    Simpson, RK
    Ondo, WG
    Tarsy, D
    Norregaard, T
    Hubble, JP
    Smith, DA
    Hauser, RA
    Jankovic, J
    JOURNAL OF NEUROSURGERY, 2006, 104 (04) : 506 - 512
  • [50] Reducing spread of neural activation using focused multipolar retinal electrical stimulation in sighted and blinded cats
    Spencer, Thomas
    Fallon, James B.
    Abbott, Carla J.
    Allen, Penny J.
    Brandli, Alice A.
    Luu, Chi D.
    Shivdasani, Mohit Naresh
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)