Evaluation of focused multipolar stimulation for cochlear implants in long-term deafened cats

被引:31
|
作者
George, Shefin S. [1 ,2 ]
Wise, Andrew K. [1 ,2 ]
Fallon, James B. [1 ,2 ]
Shepherd, Robert K. [1 ,2 ]
机构
[1] Bion Inst, East Melbourne 3002, Australia
[2] Univ Melbourne, Dept Med Bion, Melbourne, Vic 3002, Australia
基金
澳大利亚国家健康与医学研究理事会;
关键词
cochlear implant; current focusing; electrode configuration; spatial tuning curve; inferior colliculus; deafness; ELECTRICAL-STIMULATION; SPIRAL GANGLION; SPATIAL SELECTIVITY; SPEECH RECOGNITION; INFERIOR COLLICULUS; SPECTRAL CHANNELS; AUDITORY-NERVE; TRIPOLAR; PERCEPTION; EXCITATION;
D O I
10.1088/1741-2560/12/3/036003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Focused multipolar (FMP) stimulation has been shown to produce restricted neural activation using intracochlear stimulation in animals with a normal population of spiral ganglion neurons (SGNs). However, in a clinical setting, the widespread loss of SGNs and peripheral fibres following deafness is expected to influence the effectiveness of FMP. Approach. We compared the efficacy of FMP stimulation to both monopolar (MP) and tripolar (TP) stimulation in long-term deafened cat cochleae (n = 8). Unlike our previous study, these cochleae contained <10% of the normal SGN population adjacent to the electrode array. We also evaluated the effect of electrode position on stimulation modes by using either modiolar facing or lateral wall facing half-band electrodes. The spread of neural activity across the inferior colliculus, a major nucleus within the central auditory pathway, was used as a measure of spatial selectivity. Main results. In cochleae with significant SGN degeneration, we observed that FMP and TP stimulation resulted in greater spatial selectivity than MP stimulation (p < 0.001). However, thresholds were significantly higher for FMP and TP stimulation compared to MP stimulation (p < 0.001). No difference between FMP and TP stimulation was found in any measures. The high threshold levels for FMP stimulation was significantly reduced without compromising spatial selectivity by varying the degree of current focusing (referred as 'partial-FMP' stimulation). Spatial selectivity of all stimulation modes was unaffected by the electrode position. Finally, spatial selectivity in long-term deafened cochleae was significantly less than that of cochleae with normal SGN population (George S S et al 2014 J. Neural Eng. 11 065003). Significance. The present results indicate that the greater spatial selectivity of FMP and TP stimulation over MP stimulation is maintained in cochleae with significant neural degeneration and is not adversely affected by electrode position. The greater spatial selectivity of FMP and TP stimulation would be expected to result in improved clinical performance.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Articulatory changes with short-term deactivation of the cochlear implants of two prelingually deafened children
    Higgins, MB
    McCleary, EA
    Schulte, L
    EAR AND HEARING, 2001, 22 (01): : 29 - 45
  • [32] Recruitment of the auditory cortex in congenitally deaf cats by long-term cochlear electrostimulation
    Klinke, R
    Kral, A
    Heid, S
    Tillein, J
    Hartmann, R
    SCIENCE, 1999, 285 (5434) : 1729 - 1733
  • [33] Long-term predictors of narrative skill in children with early bilateral cochlear implants
    Klein, Kelsey E.
    Wie, Ona Bo
    EUROPEAN JOURNAL OF SPECIAL NEEDS EDUCATION, 2015, 30 (02) : 202 - 219
  • [34] Long-Term Language Development in Children With Early Simultaneous Bilateral Cochlear Implants
    Wie, Ona Bo
    Torkildsen, Janne von Koss
    Schauber, Stefan
    Busch, Tobias
    Litovsky, Ruth
    EAR AND HEARING, 2020, 41 (05): : 1294 - 1305
  • [35] LONG-TERM SUBDERMAL LEVONORGESTREL IMPLANTS - EVALUATION AND PROSPECTS
    FAYAD, MM
    ABDALLA, MI
    IBRAHIM, II
    EZZAT, R
    ZAKI, S
    TOPPOZADA, M
    CONTRACEPTIVE DELIVERY SYSTEMS, 1982, 3 (3-4) : 89 - 89
  • [36] EVALUATION OF LONG-TERM SOMATOTROPIN IMPLANTS IN FINISHING PIGS
    HACKER, RR
    DESCHUTTER, A
    ADEOLA, O
    KASSER, TR
    JOURNAL OF ANIMAL SCIENCE, 1993, 71 (03) : 564 - 570
  • [37] Long-Term Evolution of the Electrical Stimulation Levels for Cochlear Implant Patients
    Luis Vargas, Jose
    Sainz, Manuel
    Roldan, Cristina
    Alvarez, Isaac
    de la Torre, Angel
    CLINICAL AND EXPERIMENTAL OTORHINOLARYNGOLOGY, 2012, 5 (04) : 194 - 200
  • [38] LONG-TERM SLEEP-DEPRIVATION BY HYPOTHALAMIC-STIMULATION IN CATS
    DETARI, L
    KUKORELLI, T
    HAJNIK, T
    JOURNAL OF NEUROSCIENCE METHODS, 1993, 49 (03) : 225 - 230
  • [39] LONG-TERM IMPLANTATION OF ELECTRODES AND STIMULATION OF THE AUDITORY-NERVE IN CATS
    FINKENZELLER, P
    THUMFART, W
    FELLNER, E
    ARCHIVES OF OTO-RHINO-LARYNGOLOGY-ARCHIV FUR OHREN-NASEN-UND KEHLKOPFHEILKUNDE, 1979, 223 (2-4): : 301 - 303
  • [40] Long term results of cochlear implants in postlingual patients
    Manrique, M
    CerveraPaz, FJ
    Huarte, A
    Espinosa, JM
    Artieda, J
    GarciaTapia, R
    COCHLEAR IMPLANTS, 1996, : 255 - 259