DOSIMETRIC IMPACT OF INTERFRACTION CATHETER MOVEMENT IN HIGH-DOSE RATE PROSTATE BRACHYTHERAPY

被引:33
|
作者
Foster, William [1 ]
Cunha, J. Adam M. [1 ]
Hsu, I-Chow [1 ]
Weinberg, Vivan [1 ]
Krishnamurthy, Devan [1 ]
Pouliot, Jean [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
关键词
HDR brachytherapy; Prostate; Interfraction catheter displacement; Dosimetry; EXTERNAL-BEAM RADIOTHERAPY; HDR-BRACHYTHERAPY; CANCER; OPTIMIZATION; IMPLANT; BOOST;
D O I
10.1016/j.ijrobp.2010.01.016
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the impact of interfraction catheter movement on dosimetry in prostate high-dose-rate (HDR) brachytherapy. Methods and Materials: Fifteen patients were treated with fractionated HDR brachytherapy. Implants were performed on day 1 under transrectal ultrasound guidance. A computed tomography (CT) scan was performed. Inverse planning simulated annealing was used for treatment planning. The first fraction was delivered on day 1. A cone beam CT (CBCT) was performed on day 2 before the second fraction was given. A fusion of the CBCT and CT was performed using intraprostatic gold markers as landmarks. Initial prostate and urethra contours were transferred to the CBCT images. Bladder and rectum contours were drawn, and catheters were digitized on the CBCT. The planned treatment was applied to the CBCT dataset, and dosimetry was analyzed and compared to the initial dose distribution. This process was repeated after a reoptimization was performed, using the same constraints used on day 1. Results: Mean interfraction catheter displacement was 5.1 mm. When we used the initial plan on day 2, the mean prostate V100 (volume receiving 100 Gy or more) decreased from 93.8% to 76.2% (p < 0.01). Rectal V75 went from 0.75 cm(3) to 1.49 cm(3) (p < 0.01). A reoptimization resulted in a mean prostate V100 of 88.1%, closer to the initial plan (p = 0.05). Mean rectal V75 was also improved with a value of 0.59 cm(3). There was no significant change in bladder and urethra dose on day 2. Conclusions: A mean interfraction catheter displacement of 5.1 mm results in a significant decrease in prostate V100 And an increase in rectum dose. A reoptimization before the second treatment improves dose distribution. (C) 2011 Elsevier Inc.
引用
收藏
页码:85 / 90
页数:6
相关论文
共 50 条
  • [21] Evaluation of Dosimetric Impact of Catheter-Position Uncertainty in Balloon High Dose Rate Brachytherapy of Breast Cancer
    Kim, Y.
    Trombetta, M.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3776 - 3776
  • [22] Impact of new software tool in treatment planning for prostate high-dose rate (HDR) brachytherapy
    Sankreacha, R
    Morton, G
    Keller, B
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1388 - 1388
  • [23] Comparison of dose and catheter optimization algorithms in prostate high-dose-rate brachytherapy
    Poulin, Eric
    Varfalvy, Nicolas
    Aubin, Sylviane
    Beaulieu, Luc
    [J]. BRACHYTHERAPY, 2016, 15 (01) : 102 - 111
  • [24] Dosimetric impact of cylinder size in high-dose rate vaginal cuff brachytherapy (VCBT) for primary endometrial cancer
    Zhang, Hualin
    Gopalakrishnan, Mahesh
    Lee, Plato
    Kang, Zhuang
    Sathiaseelan, Vythialingam
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05): : 262 - 272
  • [25] Dosimetric impact of interfractional organs at risk variation during high-dose rate interstitial brachytherapy for gynecologic malignancies
    Hawkins, Peter G.
    Tang, Ming
    Vineberg, Karen A.
    Young, Lisa
    Kovach, Kelly
    Lee, Choonik
    Maturen, Katherine E.
    Uppal, Shitanshu
    Owen, Dawn
    Schipper, Matthew J.
    Prisciandaro, Joann I.
    Jolly, Shruti
    [J]. MEDICAL DOSIMETRY, 2019, 44 (03) : 239 - 244
  • [26] Advantages of High-Dose Rate (HDR) Brachytherapy in Treatment of Prostate Cancer
    Molokov, A. A.
    Vanina, E. A.
    Tseluyko, S. S.
    [J]. PHYSICS OF CANCER: INTERDISCIPLINARY PROBLEMS AND CLINICAL APPLICATIONS (PC IPCA), 2017, 1882
  • [27] The role of high-dose rate brachytherapy in locally advanced prostate cancer
    Vicini, FA
    Vargas, C
    Edmundson, G
    Kestin, L
    Martinez, A
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2003, 13 (02) : 98 - 108
  • [28] Is high-dose rate (HDR) "better than" and low-dose rate (LDR) prostate brachytherapy? A dosimetric study using retrospective data.
    Sankreacha, R
    Morton, G
    Al-Hebshi, A
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1957 - 1957
  • [29] Needle migration and dosimetric impact in high-dose-rate brachytherapy for prostate cancer evaluated by repeated MRI
    Buus, Simon
    Lizondo, Maria
    Hokland, Steffen
    Rylander, Susanne
    Pedersen, Erik M.
    Tanderup, Kari
    Bentzen, Lise
    [J]. BRACHYTHERAPY, 2018, 17 (01) : 50 - 58
  • [30] DOSIMETRIC EFFECTS OF AIR POCKETS AROUND HIGH-DOSE RATE BRACHYTHERAPY VAGINAL CYLINDERS
    Richardson, Susan
    Palaniswaamy, Geethpriya
    Grigsby, Perry W.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (01): : 276 - 279