DOSIMETRIC IMPACT OF INTERFRACTION CATHETER MOVEMENT IN HIGH-DOSE RATE PROSTATE BRACHYTHERAPY

被引:33
|
作者
Foster, William [1 ]
Cunha, J. Adam M. [1 ]
Hsu, I-Chow [1 ]
Weinberg, Vivan [1 ]
Krishnamurthy, Devan [1 ]
Pouliot, Jean [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiat Oncol, San Francisco, CA 94143 USA
关键词
HDR brachytherapy; Prostate; Interfraction catheter displacement; Dosimetry; EXTERNAL-BEAM RADIOTHERAPY; HDR-BRACHYTHERAPY; CANCER; OPTIMIZATION; IMPLANT; BOOST;
D O I
10.1016/j.ijrobp.2010.01.016
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the impact of interfraction catheter movement on dosimetry in prostate high-dose-rate (HDR) brachytherapy. Methods and Materials: Fifteen patients were treated with fractionated HDR brachytherapy. Implants were performed on day 1 under transrectal ultrasound guidance. A computed tomography (CT) scan was performed. Inverse planning simulated annealing was used for treatment planning. The first fraction was delivered on day 1. A cone beam CT (CBCT) was performed on day 2 before the second fraction was given. A fusion of the CBCT and CT was performed using intraprostatic gold markers as landmarks. Initial prostate and urethra contours were transferred to the CBCT images. Bladder and rectum contours were drawn, and catheters were digitized on the CBCT. The planned treatment was applied to the CBCT dataset, and dosimetry was analyzed and compared to the initial dose distribution. This process was repeated after a reoptimization was performed, using the same constraints used on day 1. Results: Mean interfraction catheter displacement was 5.1 mm. When we used the initial plan on day 2, the mean prostate V100 (volume receiving 100 Gy or more) decreased from 93.8% to 76.2% (p < 0.01). Rectal V75 went from 0.75 cm(3) to 1.49 cm(3) (p < 0.01). A reoptimization resulted in a mean prostate V100 of 88.1%, closer to the initial plan (p = 0.05). Mean rectal V75 was also improved with a value of 0.59 cm(3). There was no significant change in bladder and urethra dose on day 2. Conclusions: A mean interfraction catheter displacement of 5.1 mm results in a significant decrease in prostate V100 And an increase in rectum dose. A reoptimization before the second treatment improves dose distribution. (C) 2011 Elsevier Inc.
引用
收藏
页码:85 / 90
页数:6
相关论文
共 50 条
  • [31] ENDOBRONCHIAL HIGH-DOSE RATE BRACHYTHERAPY
    ALBERTI, WE
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (04): : 753 - 755
  • [32] Applicability and dosimetric impact of ultrasound-based preplanning in high-dose-rate brachytherapy of prostate cancer
    Aebersold, DM
    Isaak, B
    Thalmann, G
    Behrensmeier, F
    Kolotas, C
    Kranzbühler, H
    Mini, R
    Greiner, RH
    STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 (06) : 351 - 357
  • [33] A dosimetric comparison of high dose rate (HDR) and low dose-rate (LDR) prostate brachytherapy.
    Al-Hebshi, A
    Morton, G
    Sankreacha, R
    RADIOTHERAPY AND ONCOLOGY, 2004, 72 : S36 - S36
  • [34] Previous transurethral resection of the prostate is not a contraindication to high-dose rate brachytherapy for prostate cancer
    Luo, Hao Lun
    Fang, Fu Min
    Chuang, Yao Chi
    Chiang, Po Hui
    BJU INTERNATIONAL, 2009, 104 (11) : 1620 - 1623
  • [35] On the impact of improved dosimetric accuracy on head and neck high dose rate brachytherapy
    Peppa, Vasiliki
    Pappas, Eleftherios
    Major, Tibor
    Takacsi-Nagy, Zoltan
    Pantelis, Evaggelos
    Papagiannis, Panagiotis
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 (01) : 92 - 97
  • [36] Single Dose Compared to Fractionated High-Dose Rate Brachytherapy for Localised Prostate Cancer
    Hoskin, P.
    Rojas, A.
    Ostler, P.
    Hughes, R.
    Alonzi, R.
    Lowe, G.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S139 - S139
  • [37] Dosimetric effect of interfractional needle displacement in prostate high-dose-rate brachytherapy
    Kovalchuk, Nataliya
    Furutani, Keith M.
    MacDonald, O. Kenneth
    Pisansky, Thomas M.
    BRACHYTHERAPY, 2012, 11 (02) : 111 - 118
  • [38] A dosimetric evaluation of a single urethral constraint for high-dose-rate prostate brachytherapy
    Lu, Diana J.
    Phillips, Tiffany
    DeMarco, John
    Sandler, Howard M.
    Kamrava, Mitchell
    BRACHYTHERAPY, 2020, 19 (02) : 216 - 221
  • [39] In vivo real-time dosimetric verification in high dose rate prostate brachytherapy
    Seymour, Erin L.
    Downes, Simon J.
    Fogarty, Gerald B.
    Izard, Michael A.
    Metcalfe, Peter
    MEDICAL PHYSICS, 2011, 38 (08) : 4785 - 4794
  • [40] High dose rate prostate brachytherapy
    Nickers, P.
    Blanchard, P.
    Hannoun-Levi, J-M
    Bossi, A.
    Chapet, O.
    Guerif, S.
    CANCER RADIOTHERAPIE, 2013, 17 (02): : 118 - 124