Dosimetric impact of cylinder size in high-dose rate vaginal cuff brachytherapy (VCBT) for primary endometrial cancer

被引:4
|
作者
Zhang, Hualin [1 ]
Gopalakrishnan, Mahesh [1 ]
Lee, Plato [1 ]
Kang, Zhuang [1 ]
Sathiaseelan, Vythialingam [1 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Northwestern Mem Hosp, Dept Radiat Oncol,Robert H Lurie Comprehens Canc, Chicago, IL 60611 USA
来源
关键词
Ir-192; Brachytherapy; high dose rate; endometrial cancer; GEC-ESTRO; RADIOTHERAPY; GUIDELINES; PORTEC-2; TRIAL; AAPM;
D O I
10.1120/jacmp.v17i5.6182
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the dosimetric impact of cylinder size in high-dose-rate (HDR) vaginal cuff brachytherapy (VCBT). Sample plans of HDR VCBT in a list of cylinders ranging from 2.5 to 4 cm in diameter at 0.5 cm increment were created and analyzed. The doses were prescribed either at the 0.5 cm depth with 5.5 Gy for 4 fractions or at the cylinder surface with 8.8 Gy for 4 fractions, in various treatment lengths. A 0.5 cm shell volume called PTV_Eval was contoured for each plan and served as the target volume for dosimetric evaluation. The cumulative and differential dose volume histograms (c-DVH and d-DVH), mean doses (D-mean) and the doses covering 90% (D90), 10% (D10), and 5% (D5) of PTV_Eval were calculated. In the 0.5 cm depth regimen, the DVH curves were found to have shifted toward the lower dose zone when a larger cylinder was used, but in the surface regimen the DVH curves shifted toward the higher dose zone as the cylinder size increased. The D-means of the both regimens were between 6.9 and 7.8 Gy and dependent on the cylinder size but independent of the treatment length. A 0.5 cm variation of diameter could result in a 4% change of D-mean. Average D90s were 5.7 (ranging from 5.6 to 5.8 Gy) and 6.1 Gy (from 5.7 to 6.4 Gy), respectively, for the 0.5 cm and surface regimens. Average D10 and D5 were 9.2 and 11 Gy, respectively, for the 0.5 cm depth regimen, and 8.9 and 9.7 Gy, respectively, for the surface regimen. D-mean, D90, D10, and D5 for other prescription doses could be calculated from the lookup tables of this study. Results indicated that the cylinder size has moderate dosimetric impact, and that both regimens are comparable in dosimetric quality.
引用
收藏
页码:262 / 272
页数:11
相关论文
共 50 条
  • [1] Impact of Cylinder Size in High-Dose Rate Brachytherapy (HDRBT) for Primary Cancer in the Vagina
    Zhang, H.
    Gopalakrishnan, M.
    Lee, P.
    Sathiaseelan, V.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 361 - +
  • [2] Vaginal Applicators in High-Dose Rate Brachytherapy for Endometrial Carcinoma: A Dosimetric Study
    Khan, Aijaz Ahmad
    Vijay, Anuj
    Wani, Shaqul Qamar
    Haq, Malik Mohib-ul
    [J]. TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2023, 38 (02): : 191 - 200
  • [3] High-dose rate vaginal brachytherapy in early stage endometrial cancer
    Perrucci, E.
    Lancellotta, V.
    Bini, V.
    Mariucci, C.
    Di Benedetto, M.
    Trinari, S.
    Verzini, S.
    Aristei, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S549 - S550
  • [4] The Dosimetric Impact of Rotational Error With Multichannel Vaginal Cylinder for High Dose Rate Brachytherapy
    Kim, H.
    Glaser, S. M.
    Beriwal, S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E677 - E678
  • [5] A Dosimetric Study by Using a Multichannel Cylinder in High-Dose-Rate Brachytherapy Treatment of the Vaginal Cuff
    Syh, J. H.
    Zhang, M.
    White, M.
    Patel, B.
    Syh, J.
    Song, X.
    Wu, H.
    Rosen, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S501 - S501
  • [6] Dosimetric Advantages in Critical Structure Dose Sparing by Using a Multichannel Cylinder in High Dose Rate Brachytherapy to Treat Vaginal Cuff Cancer
    Syh, J.
    Syh, J.
    Patel, B.
    Zhang, J.
    Wu, H.
    Rosen, L.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 388 - 388
  • [7] Adjuvant high dose rate vaginal cuff brachytherapy for early stage endometrial cancer
    Tannehill, SP
    Petereit, DG
    Schink, JC
    Grosen, EA
    Hartenbach, EM
    Thomadsen, BR
    Buchler, DA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 296 - 296
  • [8] Dosimetric Comparison of Vaginal Ovoid with Cylinder Brachytherapy for Borderline Size of Tumor at the Vaginal Cuff
    Wu, X.
    Nikolaev, A.
    Bridges, D.
    Shen, S.
    Kim, R.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E754 - E754
  • [9] Salvage treatment with high-dose rate brachytherapy for isolated vaginal endometrial cancer recurrence.
    Nguyen, TV
    Petignat, P
    Alobaid, A
    Drouin, P
    Gauthier, P
    Provencher, D
    Jolicoeur, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 75 : S45 - S46
  • [10] Dosimetric Evaluation of Electronic Brachytherapy for Postsurgical Vaginal Cuff Irradiation in Endometrial Cancer
    Qian, Y.
    Lin, L. W.
    Holland, K. W.
    Shin, S. M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E365 - E365