Reliability and validity of the Biodex system 3 pro isokinetic dynamometer velocity, torque and position measurements

被引:552
|
作者
Drouin, JM
Valovich-mcLeod, TC
Shultz, SJ
Gansneder, BM
Perrin, DH
机构
[1] Georgia So Univ, Dept Publ Hlth, Statesboro, GA 30460 USA
[2] Arizona Sch Hlth Sci, Dept Sports Hlth Care, Mesa, AZ 85206 USA
[3] Univ N Carolina, Dept Exercise & Sports Sci, Greensboro, NC 27402 USA
[4] Univ Virginia, Dept Educ Leadership & Fdn, Charlottesville, VA 22904 USA
[5] Univ N Carolina, Sch Hlth & Human Performance, Greensboro, NC 27402 USA
关键词
muscle function; muscle testing; reliability; validity;
D O I
10.1007/s00421-003-0933-0
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
This study quantitatively assessed the mechanical reliability and validity of position, torque and velocity measurements of the Biodex System 3 isokinetic dynamometer. Trial-to-trial and day-to-day reliability were assessed during three trials on two separate days. To assess instrument validity, measurement of each variable using the Biodex System 3 dynamometer was compared to a criterion measure of position, torque and velocity. Position was assessed at 5degrees increments across the available range of motion of the dynamometer. Torque measures were assessed isometrically by hanging six different calibrated weights from the lever arm. Velocity was assessed (30degrees/s to 500degrees/s) across a 70degrees arc of motion by manually accelerating the weighted lever arm. With the exception of a systematic decrease in velocity at speeds of 300degrees/s and higher, the Biodex System 3 performed with acceptable mechanical reliability and validity on all variables tested.
引用
收藏
页码:22 / 29
页数:8
相关论文
共 50 条
  • [31] The Effect of Proprioceptive Exercise on Knee Active Articular Position Sense Using Biodex System 3pro
    Park, Jae-Yong
    Lee, Jung-Chul
    Bae, Jong-Jin
    Cheon, Min-Woo
    TRANSACTIONS ON ELECTRICAL AND ELECTRONIC MATERIALS, 2014, 15 (03) : 170 - 173
  • [32] Reliability of measurement of knee extensor and flexor muscle peak torque on the KinCom isokinetic dynamometer in individuals with rheumatoid arthritis
    McMeeken, JM
    Story, IH
    Smith, J
    Kent, P
    ISOKINETICS AND EXERCISE SCIENCE, 1998, 7 (02) : 67 - 73
  • [33] Reliability of a standing isokinetic shoulder rotators strength test using a functional electromechanical dynamometer: effects of velocity
    Martinez-Garcia, Dario
    Rodriguez-Perea, Angela
    Barboza, Paola
    Ulloa-Diaz, David
    Jerez-Mayorga, Daniel
    Chirosa, Ignacio
    Chirosa Rios, Luis Javier
    PEERJ, 2020, 8
  • [34] Reliability of torque measurements during passive isokinetic knee movements in healthy subjects
    Nuyens, G
    De Weerdt, W
    Spaepen, A
    Janssens, L
    Ketelaer, P
    Bogaerts, K
    SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE, 2000, 32 (02): : 61 - 65
  • [35] Validity and Reliability of upper limb muscles strength measurements by handheld dynamometer in COPD
    Beaumont, M.
    Peran, L.
    Berriet, A.
    Keller, R.
    Le Ber, C.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [36] RELIABILITY AND VALIDITY OF THE KINETIC COMMUNICATOR FOR THE MEASUREMENTS OF TORQUE, WORK AND POWER
    HANTEN, WP
    LANG, JC
    PHYSICAL THERAPY, 1988, 68 (05): : 825 - 825
  • [37] Isokinetic Dynamometer Leg Extensor Peak Torque Measurement: A Time-Delayed Reliability and Score Selection Analysis Study
    Thompson, Brennan J.
    Xu, Jennifer
    JOURNAL OF FUNCTIONAL MORPHOLOGY AND KINESIOLOGY, 2023, 8 (02)
  • [38] Reliability and validity of measurements of cervical retraction strength obtained with a hand-held dynamometer
    Tudini, Frank
    Myers, Bradley
    Bohannon, Richard
    JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2019, 27 (04) : 222 - 228
  • [39] Intratester Reliability and Validity of Concentric Measurements Using a New Hand-Held Dynamometer
    Janssen, Jessie C.
    Le-Ngoc, Lan
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2009, 90 (09): : 1541 - 1547
  • [40] Absolute reliability of isokinetic knee flexion and extension measurements adopting a prone position
    Ayala, F.
    De Ste Croix, M.
    Sainz de Baranda, P.
    Santonja, F.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2013, 33 (01) : 45 - 54